Mechanisms and the Current State of Deep Brain Stimulation in Neuropsychiatry

CNS Spectrums ◽  
2003 ◽  
Vol 8 (7) ◽  
pp. 522-526 ◽  
Author(s):  
Benjamin D. Greenberg ◽  
Ali R. Rezai

ABSTRACTDeep brain stimulation (DBS) is established as a therapy for movement disorders, and it is an investigational treatment in other neurologic conditions. DBS precisely targets neuroanatomical targets deep within the brain that are proposed to be centrally involved in the pathophysiology of some neuropsychiatric illnesses. DBS is nonablative, offering the advantages of reversibility and adjustability. This might permit therapeutic effectiveness to be enhanced or side effects to be minimized. Preclinical and clinical studies have shown effects of DBS locally, at the stimulation target, and at a distance, via actions on fibers of passage or across synapses. Although its mechanisms of action are not fully elucidated, several effects have been proposed to underlie the therapeutic effects of DBS in movement disorders, and potentially in other conditions as well. The mechanisms of action of DBS are the focus of active investigation in a number of clinical and preclinical laboratories. As in severe movement disorders, DBS may offer a degree of hope for patients with intractable neuropsychiatric illness. It is already clear that research intended to realize this potential will require a very considerable commitment of resources, energy, and time across disciplines including psychiatry, neurosurgery, neurology, neuropsychology, bioengineering, and bioethics. These investigations should proceed cautiously.

2020 ◽  
Vol 6 (1) ◽  
pp. 20-29
Author(s):  
Hongjie Jiang ◽  
Rui Wang ◽  
Zhe Zheng ◽  
Junming Zhu

Deep brain stimulation (DBS) has been used as a safe and effective neuromodulation technique for treatment of various diseases. A large number of patients suffering from movement disorders such as dyskinesia may benefit from DBS. Cerebral palsy (CP) is a group of permanent disorders mainly involving motor impairment, and medical interventions are usually unsatisfactory or temporarily active, especially for dyskinetic CP. DBS may be another approach to the treatment of CP. In this review we discuss the targets for DBS and the mechanisms of action for the treatment of CP, and focus on presurgical assessment, efficacy for dystonia and other symptoms, safety, and risks.


2008 ◽  
Author(s):  
Jonathan D. Richards ◽  
Paul M. Wilson ◽  
Pennie S. Seibert ◽  
Carin M. Patterson ◽  
Caitlin C. Otto ◽  
...  

2020 ◽  
Vol 133 (2) ◽  
pp. 403-410 ◽  
Author(s):  
Travis J. Atchley ◽  
Nicholas M. B. Laskay ◽  
Brandon A. Sherrod ◽  
A. K. M. Fazlur Rahman ◽  
Harrison C. Walker ◽  
...  

OBJECTIVEInfection and erosion following implantable pulse generator (IPG) placement are associated with morbidity and cost for patients with deep brain stimulation (DBS) systems. Here, the authors provide a detailed characterization of infection and erosion events in a large cohort that underwent DBS surgery for movement disorders.METHODSThe authors retrospectively reviewed consecutive IPG placements and replacements in patients who had undergone DBS surgery for movement disorders at the University of Alabama at Birmingham between 2013 and 2016. IPG procedures occurring before 2013 in these patients were also captured. Descriptive statistics, survival analyses, and logistic regression were performed using generalized linear mixed effects models to examine risk factors for the primary outcomes of interest: infection within 1 year or erosion within 2 years of IPG placement.RESULTSIn the study period, 384 patients underwent a total of 995 IPG procedures (46.4% were initial placements) and had a median follow-up of 2.9 years. Reoperation for infection occurred after 27 procedures (2.7%) in 21 patients (5.5%). No difference in the infection rate was observed for initial placement versus replacement (p = 0.838). Reoperation for erosion occurred after 16 procedures (1.6%) in 15 patients (3.9%). Median time to reoperation for infection and erosion was 51 days (IQR 24–129 days) and 149 days (IQR 112–285 days), respectively. Four patients with infection (19.0%) developed a second infection requiring a same-side reoperation, two of whom developed a third infection. Intraoperative vancomycin powder was used in 158 cases (15.9%) and did not decrease the infection risk (infected: 3.2% with vancomycin vs 2.6% without, p = 0.922, log-rank test). On logistic regression, a previous infection increased the risk for infection (OR 35.0, 95% CI 7.9–156.2, p < 0.0001) and a lower patient BMI was a risk factor for erosion (BMI ≤ 24 kg/m2: OR 3.1, 95% CI 1.1–8.6, p = 0.03).CONCLUSIONSIPG-related infection and erosion following DBS surgery are uncommon but clinically significant events. Their respective timelines and risk factors suggest different etiologies and thus different potential corrective procedures.


2007 ◽  
Vol 107 (5) ◽  
pp. 989-997 ◽  
Author(s):  
Yasushi Miyagi ◽  
Fumio Shima ◽  
Tomio Sasaki

Object The goal of this study was to focus on the tendency of brain shift during stereotactic neurosurgery and the shift's impact on the unilateral and bilateral implantation of electrodes for deep brain stimulation (DBS). Methods Eight unilateral and 10 bilateral DBS electrodes at 10 nuclei ventrales intermedii and 18 subthalamic nuclei were implanted in patients at Kaizuka Hospital with the aid of magnetic resonance (MR) imaging–guided and microelectrode-guided methods. Brain shift was assessed as changes in the 3D coordinates of the anterior and posterior commissures (AC and PC) with MR images before and immediately after the implantation surgery. The positions of the implanted electrodes, based on the midcommissural point and AC–PC line, were measured both on x-ray films (virtual position) during surgery and the postoperative MR images (actual position) obtained on the 7th day postoperatively. Results Contralateral and posterior shift of the AC and PC were the characteristics of unilateral and bilateral procedures, respectively. The authors suggest the following. 1) The first unilateral procedure elicits a unilateral air invasion, resulting in a contralateral brain shift. 2) During the second procedure in the bilateral surgery, the contralateral shift is reset to the midline and, at the same time, the anteroposterior support by the contralateral hemisphere against gravity is lost due to a bilateral air invasion, resulting in a significant posterior (caudal) shift. Conclusions To note the tendency of the brain to shift is very important for accurate implantation of a DBS electrode or high frequency thermocoagulation, as well as for the prediction of therapeutic and adverse effects of stereotactic surgery.


2007 ◽  
Vol 4 (5) ◽  
pp. 605-614 ◽  
Author(s):  
Sara Marceglia ◽  
Lorenzo Rossi ◽  
Guglielmo Foffani ◽  
AnnaMaria Bianchi ◽  
Sergio Cerutti ◽  
...  

2008 ◽  
Vol 30 (19) ◽  
pp. 1-5
Author(s):  
Andrew C. Zacest ◽  
Kim J. Burchiel

2011 ◽  
Vol 70 (suppl_1) ◽  
pp. ons114-ons124 ◽  
Author(s):  
Nova B. Thani ◽  
Arul Bala ◽  
Christopher R. P. Lind

Abstract BACKGROUND: Accurate placement of a probe to the deep regions of the brain is an important part of neurosurgery. In the modern era, magnetic resonance image (MRI)-based target planning with frame-based stereotaxis is the most common technique. OBJECTIVE: To quantify the inaccuracy in MRI-guided frame-based stereotaxis and to assess the relative contributions of frame movements and MRI distortion. METHODS: The MRI-directed implantable guide-tube technique was used to place carbothane stylettes before implantation of the deep brain stimulation electrodes. The coordinates of target, dural entry point, and other brain landmarks were compared between preoperative and intraoperative MRIs to determine the inaccuracy. RESULTS: The mean 3-dimensional inaccuracy of the stylette at the target was 1.8 mm (95% confidence interval [CI], 1.5-2.1. In deep brain stimulation surgery, the accuracy in the x and y (axial) planes is important; the mean axial inaccuracy was 1.4 mm (95% CI, 1.1-1.8). The maximal mean deviation of the head frame compared with brain over 24.1 ± 1.8 hours was 0.9 mm (95% CI, 0.5-1.1). The mean 3-dimensional inaccuracy of the dural entry point of the stylette was 1.8 mm (95% CI, 1.5-2.1), which is identical to that of the target. CONCLUSION: Stylette positions did deviate from the plan, albeit by 1.4 mm in the axial plane and 1.8 mm in 3-dimensional space. There was no difference between the accuracies at the dura and the target approximately 70 mm deep in the brain, suggesting potential feasibility for accurate planning along the whole trajectory.