Stem Without Spherical Aberration

1999 ◽  
Vol 5 (S2) ◽  
pp. 670-671 ◽  
Author(s):  
O.L. Krivanek ◽  
N. Dellby ◽  
A.R. Lupini

Even though two generations of electron microscopists have come to accept that the resolution of their instruments is limited by spherical aberration, three different aberration correctors showing that the aberration can be overcome have recently been built [1-3]. One of these correctors was developed by us specifically for forming small electron probes in a dedicated scanning transmission electron microscope (STEM) [3, 4]. It promises to revolutionize the way STEM instruments are built and the types of problems that they are applied to.As was the case with the Berlin Wall, when a barrier that was once thought immovable finally crumbles, many of the consequences can be quite unexpected. For STEM, the removal of spherical aberration (Cs) as the main resolution limit is likely to lead to a new paradigm in which:1) The resolution at a given operating voltage will improve by about 3x relative to today's best. When Cs can be adjusted arbitrarily in a STEM being used for microanalysis or dark field imaging, defocus and Cs are set to values that optimally oppose the effect of the 5th-order spherical aberration C5.

Author(s):  
M. G. R. Thomson

The variation of contrast and signal to noise ratio with change in detector solid angle in the high resolution scanning transmission electron microscope was discussed in an earlier paper. In that paper the conclusions were that the most favourable conditions for the imaging of isolated single heavy atoms were, using the notation in figure 1, either bright field phase contrast with β0⋍0.5 α0, or dark field with an annular detector subtending an angle between ao and effectively π/2.The microscope is represented simply by the model illustrated in figure 1, and the objective lens is characterised by its coefficient of spherical aberration Cs. All the results for the Scanning Transmission Electron Microscope (STEM) may with care be applied to the Conventional Electron Microscope (CEM). The object atom is represented as detailed in reference 2, except that ϕ(θ) is taken to be the constant ϕ(0) to simplify the integration. This is reasonable for θ ≤ 0.1 θ0, where 60 is the screening angle.


Author(s):  
Earl J. Kirkland ◽  
Robert J. Keyse

An ultra-high resolution pole piece with a coefficient of spherical aberration Cs=0.7mm. was previously designed for a Vacuum Generators HB-501A Scanning Transmission Electron Microscope (STEM). This lens was used to produce bright field (BF) and annular dark field (ADF) images of (111) silicon with a lattice spacing of 1.92 Å. In this microscope the specimen must be loaded into the lens through the top bore (or exit bore, electrons traveling from the bottom to the top). Thus the top bore must be rather large to accommodate the specimen holder. Unfortunately, a large bore is not ideal for producing low aberrations. The old lens was thus highly asymmetrical, with an upper bore of 8.0mm. Even with this large upper bore it has not been possible to produce a tilting stage, which hampers high resolution microscopy.


2001 ◽  
Vol 7 (S2) ◽  
pp. 896-897
Author(s):  
O.L. Krivanek ◽  
N. Dellby ◽  
P.D. Nellist ◽  
P.E. Batson ◽  
A.R. Lupini

Surprising as it may seem, aberration correction for the scanning transmission electron microscope (STEM) is now a practical proposition. The first-ever commercial spherical aberration corrector for a STEM was delivered by Nion to IBM Research Center in June 2000, and other deliveries have taken place since or are imminent. At the same time, the development of corrector hardware and software is still proceeding at full speed, and our understanding of what are the most important factors for the successful operation of a corrector is deepening continuously.Fig. 1 shows two high-angle dark field (HADF) images of [110] Si obtained with the IBM VG HB501 STEM operating at 120 kV, about 2 weeks after we fitted a quadrupole-octupole corrector into it. Fig. 1(a) shows the best HADF image that could be obtained with the corrector's quadrupoles on but its octupoles off. Sample structures were captured down to about 2.5 Å detail, easily possible in a STEM with a high resolution objective lens with a spherical aberration coefficient (Cs) of 1.3 mm. Fig. 1(b) shows a HADF image obtained after the Cs-correcting octupoles were turned on and the corrector tuned up. The resolution has now improved to 1.36 Å. This is sufficient to resolve the correct separation of the closely-spaced Si columns.


2000 ◽  
Vol 6 (S2) ◽  
pp. 100-101
Author(s):  
N. Dellby ◽  
O.L. Krivanek ◽  
A.R. Lupini

Electron probe formation in a scanning transmission electron microscope (STEM) has two properties that maximize the benefits of spherical aberration correction: the smallest and brightest probes are formed when all the geometric aberrations are set to zero, and the size of the probe is not greatly affected by the presence of chromatic aberration. This contrasts with the case of conventional, fixed-beam TEM (CTEM), in which optimized phase-contrast imaging demands a non-zero spherical aberration coefficient (Cs), and chromatic aberration constitutes a major resolution limit. As a result, a consensus is presently emerging that the benefits of aberration correction will be felt most strongly in STEM.Our efforts in Cs-corrected STEM have progressed from a proof-of-principle Cs corrector [1] to an optimized second-generation design [2]. The corrector in both cases is of the quadrupole-octupole type. The second-generation corrector uses separate quadrupoles and octupoles, and concentrates on maximizing the octupole strength.


2021 ◽  
Vol 106 (1) ◽  
pp. 82-96 ◽  
Author(s):  
Lei Jin ◽  
Dimitrios Koulialias ◽  
Michael Schnedler ◽  
Andreas U. Gehring ◽  
Mihály Pósfai ◽  
...  

Abstract Pyrrhotites, characterized by the chemical formula Fe1–δS (0 < δ ≤ 1/8), represent an extended group of minerals that are derived from the NiAs-type FeS aristotype. They contain layered arrangements of ordered Fe vacancies, which are at the origin of the various magnetic signals registered from certain natural rocks and can act as efficient electrocatalysts in oxygen evolution reactions in ultrathin form. Despite extensive studies over the past century, the local structural details of pyrrhotite superstructures formed by different arrangements of Fe vacancies remain unclear, in particular at the atomic scale. Here, atomic-resolution high-angle annular dark-field imaging and nanobeam electron diffraction in the scanning transmission electron microscope are used to study natural pyrrhotite samples that contain commensurate 4C and incommensurate 4.91 ± 0.02C constituents. Local measurements of both the intensities and the picometer-scale shifts of individual Fe atomic columns are shown to be consistent with a model for the structure of 4C pyrrhotite, which was derived using X-ray diffraction by Tokonami et al. (1972). In 4.91 ± 0.02C pyrrhotite, 5C-like unequally sized nano-regions are found to join at anti-phase-like boundaries, leading to the incommensurability observed in the present pyrrhotite sample. This conclusion is supported by computer simulations. The local magnetic properties of each phase are inferred from the measurements. A discussion of perspectives for the quantitative counting of Fe vacancies at the atomic scale is presented.


Author(s):  
Adam Amali ◽  
Peter Rez

The highly coherent probe in the scanning transmission electron microscope(STEM) equipped with a with high angle annular dark field (HAADF) detector has become an important tool for high resolution work in the study of crystals.with potential for providing chemically sensitive information.The results of Pennycook and Boatner and the calculations of Kirkland et al clearly demonstrated that lattice resolution was possible using HAADF imaging.There has been other contributions since then.The theoretical interpretation of these images however remains controversial and other contributions have focussed on whether the imaging is coherent or incoherent.In the present work we analyse the various mechanisms that contribute to the large angle signal obtained in the HAADF detector.Bloch waves are used to describe the elastic dynamical scattering; and in the abscence of any strong Bragg reflections.the amplitude observed in the detector plane in the STEM may be represented by a simple convolution between the scattering function of the object and the probe.


Author(s):  
J. S. Wall ◽  
J. P. Langmore ◽  
H. Isaacson ◽  
A. V. Crewe

The scanning transmission electron microscope (STEM) constructed by the authors employs a field emission gun and a 1.15 mm focal length magnetic lens to produce a probe on the specimen. The aperture size is chosen to allow one wavelength of spherical aberration at the edge of the objective aperture. Under these conditions the profile of the focused spot is expected to be similar to an Airy intensity distribution with the first zero at the same point but with a peak intensity 80 per cent of that which would be obtained If the lens had no aberration. This condition is attained when the half angle that the incident beam subtends at the specimen, 𝛂 = (4𝛌/Cs)¼