scholarly journals Development of a Segmented Detector for Aberration Corrected Scanning Transmission Electron Microscopes

2010 ◽  
Vol 16 (S2) ◽  
pp. 760-761
Author(s):  
Y Kohno ◽  
N Shibata ◽  
H Sawada ◽  
SD Findlay ◽  
Y Kondo ◽  
...  

Extended abstract of a paper presented at Microscopy and Microanalysis 2010 in Portland, Oregon, USA, August 1 – August 5, 2010.

2010 ◽  
Vol 17 (1) ◽  
pp. 75-80 ◽  
Author(s):  
Robert Hovden ◽  
Huolin L. Xin ◽  
David A. Muller

AbstractAberration-corrected scanning transmission electron microscopes (STEMs) provide sub-Angstrom lateral resolution; however, the large convergence angle greatly reduces the depth of field. For microscopes with a small depth of field, information outside of the focal plane quickly becomes blurred and less defined. It may not be possible to image some samples entirely in focus. Extended depth-of-field techniques, however, allow a single image, with all areas in focus, to be extracted from a series of images focused at a range of depths. In recent years, a variety of algorithmic approaches have been employed for bright-field optical microscopy. Here, we demonstrate that some established optical microscopy methods can also be applied to extend the ∼6 nm depth of focus of a 100 kV 5th-order aberration-corrected STEM (αmax = 33 mrad) to image Pt-Co nanoparticles on a thick vulcanized carbon support. These techniques allow us to automatically obtain a single image with all the particles in focus as well as a complimentary topography map.


2013 ◽  
Vol 19 (S2) ◽  
pp. 1238-1239
Author(s):  
G. Nicotra ◽  
Q.M. Ramasse ◽  
I. Deretzis ◽  
C. Bongiorno ◽  
C. Spinella ◽  
...  

Extended abstract of a paper presented at Microscopy and Microanalysis 2013 in Indianapolis, Indiana, USA, August 4 – August 8, 2013.


2017 ◽  
Vol 7 (1) ◽  
Author(s):  
Xiahan Sang ◽  
Andrew R. Lupini ◽  
Jilai Ding ◽  
Sergei V. Kalinin ◽  
Stephen Jesse ◽  
...  

Abstract Atomic-resolution imaging in an aberration-corrected scanning transmission electron microscope (STEM) can enable direct correlation between atomic structure and materials functionality. The fast and precise control of the STEM probe is, however, challenging because the true beam location deviates from the assigned location depending on the properties of the deflectors. To reduce these deviations, i.e. image distortions, we use spiral scanning paths, allowing precise control of a sub-Å sized electron probe within an aberration-corrected STEM. Although spiral scanning avoids the sudden changes in the beam location (fly-back distortion) present in conventional raster scans, it is not distortion-free. “Archimedean” spirals, with a constant angular frequency within each scan, are used to determine the characteristic response at different frequencies. We then show that such characteristic functions can be used to correct image distortions present in more complicated constant linear velocity spirals, where the frequency varies within each scan. Through the combined application of constant linear velocity scanning and beam path corrections, spiral scan images are shown to exhibit less scan distortion than conventional raster scan images. The methodology presented here will be useful for in situ STEM imaging at higher temporal resolution and for imaging beam sensitive materials.