Atom-Probe Tomography of Nickel-Based Superalloys with Green or Ultraviolet Lasers: A Comparative Study

2012 ◽  
Vol 18 (5) ◽  
pp. 971-981 ◽  
Author(s):  
Yaron Amouyal ◽  
David N. Seidman

AbstractRecent developments in the technology of laser-pulsed local-electrode atom-probe (LEAP) tomography include a picosecond ultraviolet (UV) laser system having a 355 nm wavelength and both external and in-vacuum optics. This approach ensures focusing of the laser beam to a smaller spot diameter than has heretofore been obtained using a green (532 nm wavelength) picosecond laser. We compare the mass spectra acquired, using either green or UV laser pulsing, from nickel-based superalloy specimens prepared either electrochemically or by lifting-out from bulk material using ion-beam milling in a dual-beam focused ion beam microscope. The utilization of picosecond UV laser pulsing yields improved mass spectra, which manifests itself in higher signal-to-noise ratios and mass-resolving power (m/Δm) in comparison to green laser pulsing. We employ LEAP tomography to investigate the formation of misoriented defects in nickel-based superalloys and demonstrate that UV laser pulsing yields better accuracy in compositional quantification than does green laser pulsing. Furthermore, we show that using a green laser the quality of mass spectra collected from specimens that were lifted-out by ion milling is usually poorer than for electrochemically-sharpened specimens. Employing UV laser pulsing yields, however, improved mass spectra in comparison to green laser pulsing even for ion-milled microtips.

2008 ◽  
Vol 14 (6) ◽  
pp. 571-580 ◽  
Author(s):  
Yang Zhou ◽  
Christopher Booth-Morrison ◽  
David N. Seidman

AbstractThe effects of varying the pulse energy of a picosecond laser used in the pulsed-laser atom-probe (PLAP) tomography of an as-quenched Ni-6.5 Al-9.5 Cr at.% alloy are assessed based on the quality of the mass spectra and the compositional accuracy of the technique. Compared to pulsed-voltage atom-probe tomography, PLAP tomography improves mass resolving power, decreases noise levels, and improves compositional accuracy. Experimental evidence suggests that Ni2+, Al2+, and Cr2+ ions are formed primarily by a thermally activated evaporation process, and not by post-ionization of the ions in the 1+ charge state. An analysis of the detected noise levels reveals that for properly chosen instrument parameters, there is no significant steady-state heating of the Ni-6.5 Al-9.5 Cr at.% tips during PLAP tomography.


2014 ◽  
Vol 20 (6) ◽  
pp. 1715-1726 ◽  
Author(s):  
R. Prakash Kolli ◽  
Frederick Meisenkothen

AbstractWe have studied the influence of experimental factors and specimen geometry on the quality of the mass spectra in copper (Cu) during pulsed-laser atom-probe tomography. We have evaluated the effects of laser pulse energy, laser pulse frequency, specimen base temperature, specimen tip radius, and specimen tip shank half-angle on the effects of mass resolving power, (m/Δm), at full-width at half-maximum and at full-width at tenth-maximum, the tail size after the major mass-to-charge state (m/n) ratio peaks, and the mass spectra. Our results indicate that mass resolving power improves with decreasing pulse energy between 40 and 80 pJ and decreasing base temperature between 20 and 80 K. The mass resolving power also improves with increasing tip radius and shank half-angle. A pulse frequency of 250 kHz slightly improves the mass resolving power relative to 100 or 500 kHz. The tail size decreases with increasing pulse energy. The mass resolving power improves when the cooling time is reduced, which is influenced by the thermal diffusivity of Cu and the specimen base temperature.


Author(s):  
L. A. Giannuzzi ◽  
P. R. Howell ◽  
H. W. Pickering ◽  
W. R. Bitler

A primary concern involving transmission electron microscopy (TEM) analysis is whether the electron transparent region under investigation is representative of the bulk material. TEM is frequently employed to examine the microstructure of electrodeposited materials due to their small grain size and high dislocation density. Previous work in this laboratory on palladium electrodeposits has shown that deformation twins and diffusion induced recrystallization may be induced during preparation of thin foils using both twin jet electropolishing and ion beam thinning. Recent developments in TEM sample preparation in the physical sciences include a procedure for the cross-section of heterogeneous layered materials which reduces or eliminates the need for ion milling. In this sample preparation technique, a tripod polisher device is used to mechanically polish the specimen to electron transparency. The purpose of this paper is to report on the influence of the tripod polisher sample preparation technique, on the microstructure of zinc electrodeposits.


2017 ◽  
Vol 23 (2) ◽  
pp. 385-395 ◽  
Author(s):  
Brian Langelier ◽  
Hugo P. Van Landeghem ◽  
Gianluigi A. Botton ◽  
Hatem S. Zurob

AbstractImproved understanding of the interactions between solutes and the austenite/ferrite interface can benefit modeling of ferrite growth during austenite decomposition, as the transformation kinetic is significantly affected by solutes that influence interface mobility. Solute-interface interactions dominate solute segregation at the interface in binary systems, but in multi-component alloys, solute–solute interactions may also affect segregation. In this study, interface segregation in Fe–Mn–N is examined and compared with Fe–Mn–C, to reveal the extent to which C affects the segregation of Mn. Atom probe tomography (APT) is well-suited to analyze solute concentrations across the interface, as this technique combines high spatial resolution and compositional sensitivity. Measurements of Mn show that segregation is only observed for Fe–Mn–C. This demonstrates that Mn segregation is primarily driven by an affinity for C, which also segregates to the interface. However, the measurement of N in steels by APT may be affected by a variety of experimental factors. Therefore, in verifying the Fe–Mn–N result, systematic examination is conducted on the influence of pulsing method (voltage versus laser), sample preparation (ion milling versus electropolishing), and vacuum storage on the measured N concentration. Both laser pulsing and focused ion beam sample preparation are observed to decrease the apparent N concentration.


2005 ◽  
Vol 13 (1) ◽  
pp. 26-29 ◽  
Author(s):  
R.B. Irwin ◽  
A. Anciso ◽  
P.J. Jones ◽  
C. Patton

Sample preparation for Transmission Electron Microscopy (TEM) is usually performed such that the final sample orientation is either a cross section or a plan view of the bulk material, as shown schematically in Figure 1. The object of any sample preparation technique, for either of these two orientations, is to thin a selected volume of the sample from its initial bulk state to electron transparency, ~ 100nm thick. In doing so, the final sample must be mechanically stable, vacuum compatible, and, most of all, unchanged from the initial bulk material. Many techniques have been used to achieve this goal: cleaving, sawing, mechanical polishing, chemical etching, ion milling, focused ion beam (FIB) milling, and many others.


2017 ◽  
Vol 23 (2) ◽  
pp. 404-413 ◽  
Author(s):  
Alexandre La Fontaine ◽  
Sandra Piazolo ◽  
Patrick Trimby ◽  
Limei Yang ◽  
Julie M. Cairney

AbstractThe application of atom probe tomography to the study of minerals is a rapidly growing area. Picosecond-pulsed, ultraviolet laser (UV-355 nm) assisted atom probe tomography has been used to analyze trace element mobility within dislocations and low-angle boundaries in plastically deformed specimens of the nonconductive mineral zircon (ZrSiO4), a key material to date the earth’s geological events. Here we discuss important experimental aspects inherent in the atom probe tomography investigation of this important mineral, providing insights into the challenges in atom probe tomography characterization of minerals as a whole. We studied the influence of atom probe tomography analysis parameters on features of the mass spectra, such as the thermal tail, as well as the overall data quality. Three zircon samples with different uranium and lead content were analyzed, and particular attention was paid to ion identification in the mass spectra and detection limits of the key trace elements, lead and uranium. We also discuss the correlative use of electron backscattered diffraction in a scanning electron microscope to map the deformation in the zircon grains, and the combined use of transmission Kikuchi diffraction and focused ion beam sample preparation to assist preparation of the final atom probe tip.


Author(s):  
P.G. Pawar ◽  
P. Duhamel ◽  
G.W. Monk

A beam of ions of mass greater than a few atomic mass units and with sufficient energy can remove atoms from the surface of a solid material at a useful rate. A system used to achieve this purpose under controlled atmospheres is called an ion miliing machine. An ion milling apparatus presently available as IMMI-III with a IMMIAC was used in this investigation. Unless otherwise stated, all the micro milling operations were done with Ar+ at 6kv using a beam current of 100 μA for each of the two guns, with a specimen tilt of 15° from the horizontal plane.It is fairly well established that ion bombardment of the surface of homogeneous materials can produce surface topography which resembles geological erosional features.


Author(s):  
E.A. Fischione ◽  
P.E. Fischione ◽  
J.J. Haugh ◽  
M.G. Burke

A common requirement for both Atom Probe Field-Ion Microscopy (APFIM) and Scanning Tunnelling Microscopy (STM) is a sharp pointed tip for use as either the specimen (APFIM) or the probe (STM). Traditionally, tips have been prepared by either chemical or electropolishing techniques. Recently, ion-milling has been successfully employed in the production of APFIM tips [1]. Conventional electropolishing techniques are applicable to a wide variety of metals, but generally require careful manual adjustments during the polishing process and may also be time-consuming. In order to reduce the time and effort involved in the preparation process, a compact, self-contained polishing unit has been developed. This system is based upon the conventional two-stage electropolishing technique in which the specimen/tip blank is first locally thinned or “necked”, and subsequently electropolished until separation occurs.[2,3] The result of this process is the production of two APFIM or STM tips. A mechanized polishing unit that provides these functions while automatically maintaining alignment has been designed and developed.


2018 ◽  
Author(s):  
C.S. Bonifacio ◽  
P. Nowakowski ◽  
M.J. Campin ◽  
M.L. Ray ◽  
P.E. Fischione

Abstract Transmission electron microscopy (TEM) specimens are typically prepared using the focused ion beam (FIB) due to its site specificity, and fast and accurate thinning capabilities. However, TEM and high-resolution TEM (HRTEM) analysis may be limited due to the resulting FIB-induced artifacts. This work identifies FIB artifacts and presents the use of argon ion milling for the removal of FIB-induced damage for reproducible TEM specimen preparation of current and future fin field effect transistor (FinFET) technologies. Subsequently, high-quality and electron-transparent TEM specimens of less than 20 nm are obtained.


Sign in / Sign up

Export Citation Format

Share Document