Quantitative Determination of Maleic Anhydride, Benzoic Acid, Naphthalene, and 1,4-Naphthoquinone in Phthalic Anhydride by Gas Liquid Chromatography.

1964 ◽  
Vol 36 (2) ◽  
pp. 269-271 ◽  
Author(s):  
Helen. Trachman ◽  
Frederick. Zucker
1962 ◽  
Vol 34 (11) ◽  
pp. 1503-1504 ◽  
Author(s):  
C. E. Moore ◽  
Siegfried Meinstein

1963 ◽  
Vol 46 (6) ◽  
pp. 950-951
Author(s):  
Richard L Brunelle ◽  
Glenn E Martin

Abstract A rapid and specific method is given for determination of benzaldehyde in the presence of interfering substances by gas-liquid chromatography. Separation is effected on a ¼ column containing 2 5% Apiezon M as the liquid phase on a solid support of Chromoport XXX (60—80 mesh) at isothermal conditions, 100°C. The determination can be performed in the presence of benzoic acid and other interfering substances. Results are compared with those obtained by ultraviolet spectrophotometry on a variety of almond and cherry flavors.


1971 ◽  
Vol 51 (3) ◽  
pp. 447-454 ◽  
Author(s):  
W. COOPER ◽  
M. G. COYLE ◽  
J. A. MILLS

SUMMARY A method is described for estimating oestriol in 2–10 ml samples of human pregnancy peripheral plasma. It incorporates acid hydrolysis, chemical purification, methylation, chromatography on alumina columns, formation of a derivative and quantitative determination by gas chromatography. A radioactive internal standard was added to correct for procedural losses. Plasma oestriol determinations in five normal patients throughout pregnancy and delivery are reported.


1971 ◽  
Vol 54 (2) ◽  
pp. 361-363
Author(s):  
D E LaCroix ◽  
N P Wong

Abstract A rapid method is described for the extraction and quantitative determination of sorbic acid in Cheddar cheese. Cheddar cheese is impregnated onto a Celite 545 column, extracted with acetonitrile, and analyzed for sorbic acid by gas-liquid chromatography, using a 7.5% ethylene glycol adipate + 2% H3PO4 column. Average recovery values for known amounts of sorbic acid were 107%.


1973 ◽  
Vol 19 (5) ◽  
pp. 492-495 ◽  
Author(s):  
M A Evenson ◽  
Susan Koellner

Abstract Rapid, accurate, and precise gas-chromatographic methods are reported for measurement of propoxyphene ("Darvon") in serum. A sample of 5 ml of serum is required for quantitation in blood after a therapeutic dose of 130-195 mg of propoxyphene; in cases of overdose of propoxyphene, only 1 ml of serum is required in a "toxic method" variation. Neither serum from healthy controls or from hospitalized patients contains interfering substances. Several commonly used analgesic and sedative drugs, added to a serum pool, also did not interfere. Day-to-day precision of the therapeutic method, as measured by the coefficient of variation (CV), is 7%; the CV for the method as applied to overdose cases is less than 3%. Propoxyphene added to serum could be about 86% accounted for analytically.


Sign in / Sign up

Export Citation Format

Share Document