scholarly journals Suppression of X-ray-Induced Radiation Damage to Biomolecules in Aqueous Environments by Immediate Intermolecular Decay of Inner-Shell Vacancies

Author(s):  
Andreas Hans ◽  
Philipp Schmidt ◽  
Catmarna Küstner-Wetekam ◽  
Florian Trinter ◽  
Sascha Deinert ◽  
...  
Author(s):  
Shawn Williams ◽  
Xiaodong Zhang ◽  
Susan Lamm ◽  
Jack Van’t Hof

The Scanning Transmission X-ray Microscope (STXM) is well suited for investigating metaphase chromosome structure. The absorption cross-section of soft x-rays having energies between the carbon and oxygen K edges (284 - 531 eV) is 6 - 9.5 times greater for organic specimens than for water, which permits one to examine unstained, wet biological specimens with resolution superior to that attainable using visible light. The attenuation length of the x-rays is suitable for imaging micron thick specimens without sectioning. This large difference in cross-section yields good specimen contrast, so that fewer soft x-rays than electrons are required to image wet biological specimens at a given resolution. But most imaging techniques delivering better resolution than visible light produce radiation damage. Soft x-rays are known to be very effective in damaging biological specimens. The STXM is constructed to minimize specimen dose, but it is important to measure the actual damage induced as a function of dose in order to determine the dose range within which radiation damage does not compromise image quality.


Author(s):  
C. Goessens ◽  
D. Schryvers ◽  
J. Van Landuyt ◽  
A. Verbeeck ◽  
R. De Keyzer

Silver halide grains (AgX, X=Cl,Br,I) are commonly recognized as important entities in photographic applications. Depending on the preparation specifications one can grow cubic, octahedral, tabular a.o. morphologies, each with its own physical and chemical characteristics. In the present study crystallographic defects introduced by the mixing of 5-20% iodide in a growing AgBr tabular grain are investigated. X-ray diffractometry reveals the existence of a homogeneous Ag(Br1-xIx) region, expected to be formed around the AgBr kernel. In fig. 1 a two-beam BF image, taken at T≈100 K to diminish radiation damage, of a triangular tabular grain is presented, clearly showing defect contrast fringes along four of the six directions; the remaining two sides show similar contrast under relevant diffraction conditions. The width of the central defect free region corresponds with the pure AgBr kernel grown before the mixing with I. The thickness of a given grain lies between 0.15 and 0.3 μm: as indicated in fig. 2 triangular (resp. hexagonal) grains exhibit an uneven (resp. even) number of twin interfaces (i.e., between + and - twin variants) parallel with the (111) surfaces. The thickness of the grains and the existence of the twin variants was confirmed from CTEM images of perpendicular cuts.


Author(s):  
T.W. Jeng ◽  
W. Chiu

With the advances in preparing biological materials in a thin and highly ordered form, and in maintaining them hydrated under vacuum, electron crystallography has become an important tool for biological structure investigation at high resolution (1,2). However, the electron radiation damage would limit the capability of recording reflections with low intensities in an electron diffraction pattern. It has been demonstrated that the use of a low temperature stage can reduce the radiation damage effect and that one can expose the specimen with a higher dose in order to increase the signal contrast (3). A further improvement can be made by selecting a proper photographic emulsion. The primary factors in evaluating the suitability of photographic emulsion for recording low dose diffraction patterns are speed, fog level, electron response at low electron exposure, linearity, and usable range of exposure. We have compared these factors with three photographic emulsions including Kodak electron microscopic plate (EMP), Industrex AA x-ray film (AA x-ray) and Kodak nuclear track film (NTB3).


2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Marc Benjamin Hahn ◽  
Paul M. Dietrich ◽  
Jörg Radnik

AbstractIonizing radiation damage to DNA plays a fundamental role in cancer therapy. X-ray photoelectron-spectroscopy (XPS) allows simultaneous irradiation and damage monitoring. Although water radiolysis is essential for radiation damage, all previous XPS studies were performed in vacuum. Here we present near-ambient-pressure XPS experiments to directly measure DNA damage under water atmosphere. They permit in-situ monitoring of the effects of radicals on fully hydrated double-stranded DNA. The results allow us to distinguish direct damage, by photons and secondary low-energy electrons (LEE), from damage by hydroxyl radicals or hydration induced modifications of damage pathways. The exposure of dry DNA to x-rays leads to strand-breaks at the sugar-phosphate backbone, while deoxyribose and nucleobases are less affected. In contrast, a strong increase of DNA damage is observed in water, where OH-radicals are produced. In consequence, base damage and base release become predominant, even though the number of strand-breaks increases further.


2009 ◽  
Vol 194 (2) ◽  
pp. 022107
Author(s):  
M Gisselbrecht ◽  
M Tchaplyguine ◽  
F Burmeister ◽  
S Svensson ◽  
O Björneholm ◽  
...  

1996 ◽  
Author(s):  
Hiroshi Tomida ◽  
Hironori Matsumoto ◽  
Masanobu Ozaki ◽  
Yuji Tazawa ◽  
Hisamitsu Awaki ◽  
...  
Keyword(s):  

2013 ◽  
Vol 69 (a1) ◽  
pp. s407-s408
Author(s):  
Markus Gerstel ◽  
Natalya Olekhnovich ◽  
Jonathan Brooks-Bartlett ◽  
Zygmunt S. Derewenda ◽  
Charlotte M. Deane ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document