Enhanced Emission of Zinc Nitride Colloidal Nanoparticles with Organic Dyes for Optical Sensors and Imaging Application

2020 ◽  
Vol 12 (17) ◽  
pp. 19245-19257 ◽  
Author(s):  
Soundharraj Prabha ◽  
Dhinasekaran Durgalakshmi ◽  
Karthikeyan Subramani ◽  
Prakasarao Aruna ◽  
Singaravelu Ganesan
2012 ◽  
Vol 326-328 ◽  
pp. 682-689
Author(s):  
Aleksandra Lobnik ◽  
Špela Korent Urek ◽  
Matejka Turel

Luminescent sensors are chemical systems that can deliver information on the presence of selected analytes through the variations in their luminescence emission. With the advent of luminescent nanoparticles several new applications in the field of chemical sensing were explored. Among them, quantum dots (QD) represent inorganic semiconductor nanocrystals that are advantageous over conventional organic dyes from many different points of view. In this short review, the optical detection of various analytes using QD-based probes/sensors is presented and significant sensors characteristics are discussed. The biosensing approaches are not included in this article.


Nanomaterials ◽  
2019 ◽  
Vol 9 (2) ◽  
pp. 192 ◽  
Author(s):  
Anna Lesiak ◽  
Kamila Drzozga ◽  
Joanna Cabaj ◽  
Mateusz Bański ◽  
Karol Malecha ◽  
...  

Fundamentals of quantum dots (QDs) sensing phenomena show the predominance of these fluorophores over standard organic dyes, mainly because of their unique optical properties such as sharp and tunable emission spectra, high emission quantum yield and broad absorption. Moreover, they also indicate no photo bleaching and can be also grown as no blinking emitters. Due to these properties, QDs may be used e.g., for multiplex testing of the analyte by simultaneously detecting multiple or very weak signals. Physico-chemical mechanisms used for analyte detection, like analyte stimulated QDs aggregation, nonradiative Förster resonance energy transfer (FRET) exhibit a number of QDs, which can be applied in sensors. Quantum dots-based sensors find use in the detection of ions, organic compounds (e.g., proteins, sugars, volatile substances) as well as bacteria and viruses.


1993 ◽  
Vol 11 (1-3) ◽  
pp. 331-340 ◽  
Author(s):  
K.R.A.S. Sandanayake ◽  
I.O. Sutherland
Keyword(s):  

VASA ◽  
2015 ◽  
Vol 44 (5) ◽  
pp. 355-362 ◽  
Author(s):  
Marie Urban ◽  
Alban Fouasson-Chailloux ◽  
Isabelle Signolet ◽  
Christophe Colas Ribas ◽  
Mathieu Feuilloy ◽  
...  

Abstract. Summary: Background: We aimed at estimating the agreement between the Medicap® (photo-optical) and Radiometer® (electro-chemical) sensors during exercise transcutaneous oxygen pressure (tcpO2) tests. Our hypothesis was that although absolute starting values (tcpO2rest: mean over 2 minutes) might be different, tcpO2-changes over time and the minimal value of the decrease from rest of oxygen pressure (DROPmin) results at exercise shall be concordant between the two systems. Patients and methods: Forty seven patients with arterial claudication (65 + / - 7 years) performed a treadmill test with 5 probes each of the electro-chemical and photo-optical devices simultaneously, one of each system on the chest, on each buttock and on each calf. Results: Seventeen Medicap® probes disconnected during the tests. tcpO2rest and DROPmin values were higher with Medicap® than with Radiometer®, by 13.7 + / - 17.1 mm Hg and 3.4 + / - 11.7 mm Hg, respectively. Despite the differences in absolute starting values, changes over time were similar between the two systems. The concordance between the two systems was approximately 70 % for classification of test results from DROPmin. Conclusions: Photo-optical sensors are promising alternatives to electro-chemical sensors for exercise oximetry, provided that miniaturisation and weight reduction of the new sensors are possible.


2020 ◽  
pp. 38-44
Author(s):  
A. V. Polyakov ◽  
M. A. Ksenofontov

Optical technologies for measuring electrical quantities attract great attention due to their unique properties and significant advantages over other technologies used in high-voltage electric power industry: the use of optical fibers ensures high stability of measuring equipment to electromagnetic interference and galvanic isolation of high-voltage sensors; external electromagnetic fields do not influence the data transmitted from optical sensors via fiber-optic communication lines; problems associated with ground loops are eliminated, there are no side electromagnetic radiation and crosstalk between the channels. The structure and operation principle of a quasi-distributed fiber-optic high-voltage monitoring system is presented. The sensitive element is a combination of a piezo-ceramic tube with an optical fiber wound around it. The device uses reverse transverse piezoelectric effect. The measurement principle is based on recording the change in the recirculation frequency under the applied voltage influence. When the measuring sections are arranged in ascending order of the measured effective voltages relative to the receiving-transmitting unit, a relative resolution of 0,3–0,45 % is achieved for the PZT-5H and 0,8–1,2 % for the PZT-4 in the voltage range 20–150 kV.


2004 ◽  
Vol 9 (1) ◽  
pp. 55-63
Author(s):  
V. Kleiza

Light transmission in the reflection fiber system, located in external optical media, has been investigated for application as sensors. The system was simulated by different models, including external cavity parameters such as the distance between light emitting and receiving fibers and mirror positioning distance. The sensitivity to a linear displacement of the sensors was studied as a function of the distance between the tips of the light emitting fiber and the center of the pair reflected light collecting fibers, by positioning a mirror. Physical fundamentals and operating principles of the advanced fiber optical sensors were revealed.


Sign in / Sign up

Export Citation Format

Share Document