Synthesis of Graphitic Ordered Macroporous Carbon with a Three-Dimensional Interconnected Pore Structure for Electrochemical Applications

2005 ◽  
Vol 109 (43) ◽  
pp. 20200-20206 ◽  
Author(s):  
Fabing Su ◽  
X. S. Zhao ◽  
Yong Wang ◽  
Jianhuang Zeng ◽  
Zuocheng Zhou ◽  
...  
2017 ◽  
Vol 75 ◽  
pp. 590-595 ◽  
Author(s):  
Lijun Ji ◽  
Wei Qiao ◽  
Kai Huang ◽  
Yuheng Zhang ◽  
Huayu Wu ◽  
...  

2005 ◽  
Vol 287 ◽  
pp. 323-328 ◽  
Author(s):  
Lan Young Hong ◽  
Dong Pyo Kim

Macroporous SiCBN and BCN ceramic were prepared by infiltrating these preceramic polymers into the colloidal silica crystalline array, followed by pyrolysis at 1400ı and subsequently etching off the silica spheres. It is generally observed by SEM and TEM that a highly ordered and interconnected 'honeycomb' pore structure was obtained by replicating the three dimensional close packed silica spheres which was fabricated by natural sedimentation. And BET surface areas in range 413 ~ 315 m2/g and pore sizes of 113 ~ 395 nm in the porous materials were tailored by controlling the sacrificial silica sphere sizes in range 145~500 nm even under volume shrinkage involved during pyrolytic step. The porous SiCBN ceramics and BCN ceramic showed a slight weight loss of 0.2~0.8% and 4%, respectively, indicating excellent resistance to oxidation.


2012 ◽  
Vol 450-451 ◽  
pp. 445-453 ◽  
Author(s):  
Fu Jian Tang ◽  
Gen Da Chen ◽  
Jeffery S. Volz ◽  
Richard K. Brow ◽  
Michael Koenigstein

In this study, the corrosion process of enamel-coated deformed rebar completely immersed in 3.5 wt.% NaCl solution was evaluated over a period of 84 days by EIS testing. Three types of enamel coating were investigated: pure enamel, 50/50 enamel coating, and double enamel. Surface condition of the enamel coatings that were intentionally damaged prior to corrosion tests was visually examined at different immersion times. After 84 days of testing, the damaged coating areas were characterized by SEM, and the corrosion products on and adjacent to the damaged areas were collected and analyzed by XRD. Corrosion initiated at the damaged locations with no undercutting of the coating observed. The 50/50 enamel coating had the least corrosion resistance, due to its interconnected pore structure, and prior damage drastically reduced the corrosion resistance of pure and double enamel coated rebar.


RSC Advances ◽  
2016 ◽  
Vol 6 (25) ◽  
pp. 20926-20937 ◽  
Author(s):  
Libing Zheng ◽  
Jun Wang ◽  
Yuansong Wei ◽  
Yong Zhang ◽  
Kun Li ◽  
...  

PVDF-CTFE membrane with interconnected pore structure, narrow pore distribution, and high DCMD performance was prepared by study the effect of molecular weight and dosage of PEG.


Sign in / Sign up

Export Citation Format

Share Document