scholarly journals Impact of sample pretreatment on the measured element concentrations in the bivalveArctica islandica

2011 ◽  
Vol 12 (7) ◽  
pp. n/a-n/a ◽  
Author(s):  
Jacqueline Krause-Nehring ◽  
Andreas Klügel ◽  
Gernot Nehrke ◽  
Bernd Brellochs ◽  
Thomas Brey
Author(s):  
H.J. Dudek

The chemical inhomogenities in modern materials such as fibers, phases and inclusions, often have diameters in the region of one micrometer. Using electron microbeam analysis for the determination of the element concentrations one has to know the smallest possible diameter of such regions for a given accuracy of the quantitative analysis.In th is paper the correction procedure for the quantitative electron microbeam analysis is extended to a spacial problem to determine the smallest possible measurements of a cylindrical particle P of high D (depth resolution) and diameter L (lateral resolution) embeded in a matrix M and which has to be analysed quantitative with the accuracy q. The mathematical accounts lead to the following form of the characteristic x-ray intens ity of the element i of a particle P embeded in the matrix M in relation to the intensity of a standard S


2016 ◽  
Author(s):  
Matthew Costa ◽  
◽  
Carley M. Cavanaugh ◽  
Oluyinka Oyewumi

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Anita G. Amin ◽  
Prithwiraj De ◽  
Barbara Graham ◽  
Roger I. Calderon ◽  
Molly F. Franke ◽  
...  

AbstractOur study sought to determine whether urine lipoarabinomannan (LAM) could be validated in a sample cohort that consisted mainly of HIV uninfected individuals that presented with tuberculosis symptoms. We evaluated two tests developed in our laboratory, and used them on clinical samples from Lima, Peru where incidence of HIV is low. ELISA analysis was performed on 160 samples (from 140 adult culture-confirmed TB cases and 20 symptomatic TB-negative child controls) using 100 μL of urine after pretreatment with Proteinase K. Two different mouse monoclonal antibodies-CS35 and CHCS9-08 were used individually for capture of urine LAM. Among cases, optical density (OD450) values had a positive association with higher bacillary loads. The 20 controls had negative values (below the limit of detection). The assay correctly identified all samples (97–100% accuracy confidence interval). For an alternate validation of the ELISA results, we analyzed all 160 urine samples using an antibody independent chemoanalytical approach. Samples were called positive only when LAM surrogates—tuberculostearic acid (TBSA) and d-arabinose (d-ara)—were found to be present in similar amounts. All TB cases, including the 40 with a negative sputum smear had LAM in detectable quantities in urine. None of the controls had detectable amounts of LAM. Our study shows that urinary LAM detection is feasible in HIV uninfected, smear negative TB patients.


Author(s):  
Emily Silva ◽  
Shaodan Huang ◽  
Joy Lawrence ◽  
Marco A.G. Martins ◽  
Jing Li ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document