Reply [ to “Comment on “Increase of ion kinetic temperature across a collisionless shock: I. A new concept by L. C. Lee et al.” and “Ion acceleration in quasiperpendicular magnetosonic shock waves with subcritical Mach number by Y. Ohsawa and J. Sakai””]

1986 ◽  
Vol 13 (6) ◽  
pp. 565-566
Author(s):  
Y. Ohsawa
Shock Tubes ◽  
1970 ◽  
pp. 463-474
Author(s):  
L. S. Levine ◽  
I. M. Vitkovitsky ◽  
A. C. Kolb

Author(s):  
P. M. Ligrani ◽  
C. Saumweber ◽  
A. Schulz ◽  
S. Wittig

Interactions between shock waves and film cooling are described as they affect magnitudes of local and spanwise-averaged adiabatic film cooling effectiveness distributions. A row of three cylindrical holes is employed. Spanwise spacing of holes is 4 diameters, and inclination angle is 30 degrees. Freestream Mach numbers of 0.8 and 1.10–1.12 are used, with coolant to freestream density ratios of 1.5–1.6. Shadowgraph images show different shock structures as the blowing ratio is changed, and as the condition employed for injection of film into the cooling holes is altered. Investigated are film plenum conditions, as well as perpendicular film injection cross-flow Mach numbers of 0.15, 0.3, and 0.6. Dramatic changes to local and spanwise-averaged adiabatic film effectiveness distributions are then observed as different shock wave structures develop in the immediate vicinity of the film-cooling holes. Variations are especially evident as the data obtained with a supersonic Mach number are compared to the data obtained with a freestream Mach number of 0.8. Local and spanwise-averaged effectiveness magnitudes are generally higher when shock waves are present when a film plenum condition (with zero cross-flow Mach number) is utilized. Effectiveness values measured with a supersonic approaching freestream and shock waves then decrease as the injection cross-flow Mach number increases. Such changes are due to altered flow separation regions in film holes, different injection velocity distributions at hole exits, and alterations of static pressures at film hole exits produced by different types of shock wave events.


2013 ◽  
Author(s):  
Yuqiang Dai ◽  
Fengxia Liu ◽  
Jintao Wu ◽  
Wei Wei ◽  
Dapeng Hu ◽  
...  

As a novel generation of rotational gas wave machines, wave rotor machines such as wave rotor refrigerators (WRR) and wave rotor superchargers (WRS) are unsteady flow devices. In their passages two gas streams (with different pressure or even different phases) comes into direct contact can exchange energy due to the movement of shock waves and expansion waves. A detailed study shows that, when rotor channels open to the high pressure port gradually, the contact face in rotor channels inevitably skews, which is always accompanied with reflection of shockwaves. This causes very large energy dissipation and influences adversely on the refrigeration performance of WRR or the supercharging performance of WRS. In this work, factors such as centrifugal forces, Coriolis forces, gradual channel opening and gradual channel closing, etc, which influence the wave transportation and skewing of shock waves and contact faces are studied by means of computational fluid dynamics and experiments. The skewing of contact faces causes uneven distribution of velocity and large local loss. With rotation Mach number smaller than 0.3, the skewing of contact face can be alleviated. To reduce the adverse influence of rotation Mach number, a smaller rotor channel width or higher rotational speed is necessary. The rotation effect plays an important role for the skewing of gas discontinuities. Both the centrifugal and Coriolis forces of wave rotor cannot be ignored with the Rossby number of 1.3∼3.5. To reduce the skewing loss of contact face, a lower rotational speed seems necessary. The rotation speed of wave rotors has dialectical influences on the skewing of shock waves and contact faces. The jetting width of high pressure port is the key factor of the gradual opening of rotor channels. A feasible way to reduce skewing losses of gas waves is to optimize the ratio between high pressure port width and channel width. The validation experiments have got at least 3∼5% rise of isentropic efficiency for WRRs.


Sign in / Sign up

Export Citation Format

Share Document