scholarly journals Age-associated changes in 4D flow CMR derived Tricuspid Valvular Flow and Right Ventricular Blood Flow Kinetic Energy

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Natasha Barker ◽  
Hamza Zafar ◽  
Benjamin Fidock ◽  
Alaa Elhawaz ◽  
Abdallah Al-Mohammad ◽  
...  
2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Ciaran Grafton-Clarke ◽  
Saul Crandon ◽  
Jos J. M. Westenberg ◽  
Peter P. Swoboda ◽  
John P. Greenwood ◽  
...  

Abstract Objectives Four-dimensional flow CMR allows for a comprehensive assessment of the blood flow kinetic energy of the ventricles of the heart. In comparison to standard two-dimensional image acquisition, 4D flow CMR is felt to offer superior reproducibility, which is important when repeated examinations may be required. The objective was to evaluate the inter-observer and intra-observer reproducibility of blood flow kinetic energy assessment using 4D flow of the left ventricle in 20 healthy volunteers across two centres in the United Kingdom and the Netherlands. Data description This dataset contains 4D flow CMR blood flow kinetic energy data for 20 healthy volunteers with no known cardiovascular disease. Presented is kinetic energy data for the entire cardiac cycle (global), the systolic and diastolic components, in addition to blood flow kinetic energy for both early and late diastolic filling. This data is available for reuse and would be valuable in supporting other research, such as allowing for larger sample sizes with more statistical power for further analysis of these variables.


2018 ◽  
Vol 8 (1) ◽  
Author(s):  
Saul Crandon ◽  
Jos J. M. Westenberg ◽  
Peter P. Swoboda ◽  
Graham J. Fent ◽  
James R. J. Foley ◽  
...  

Author(s):  
Philip A Corrado ◽  
Gregory P Barton ◽  
Christopher J François ◽  
Oliver Wieben ◽  
Kara N Goss

Background: Extreme preterm birth conveys an elevated risk of heart failure by young adulthood. Smaller biventricular chamber size, diastolic dysfunction, and pulmonary hypertension may contribute to reduced ventricular-vascular coupling. However, how hemodynamic manipulations may affect right ventricular (RV) function and coupling remains unknown. Methods: As a pilot study, 4D flow MRI was used to assess the effect of afterload reduction and heart rate reduction on cardiac hemodynamics and function. Young adults born premature were administered sildenafil (a pulmonary vasodilator) and metoprolol (a beta blocker) on separate days, and MRI with 4D flow completed before and after each drug administration. Endpoints include cardiac index (CI), direct flow fractions, and ventricular kinetic energy including E/A wave kinetic energy ratio. Results: Sildenafil resulted in a median CI increase of 0.24 L/min/m2 (P=0.02), mediated through both an increase in heart rate (HR) and stroke volume. Although RV ejection fraction improved only modestly, there was a significant increase (4% of end diastolic volume) in RV direct flow fraction (P=0.04), consistent with hemodynamic improvement. Metoprolol administration resulted in a 5-bpm median decrease in HR (P=0.01), a 0.37 L/min/m2 median decrease in CI (P=0.04), and a reduction in time-averaged kinetic energy (KE) in both ventricles (P<0.01), despite increased RV diastolic E/A KE ratio (P=0.04). Conclusions: Despite reduced right atrial workload, metoprolol significantly depressed overall cardiac systolic function. Sildenafil, however, increased CI and improved RV function, as quantified by the direct flow fraction. The preterm heart appears dependent on HR, but sensitive to RV afterload manipulations.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Victoria Stoll ◽  
Aaron Hess ◽  
Eylem Levelt ◽  
Jonatan Eriksson ◽  
Petter Dyverfeldt ◽  
...  

Introduction: Heart failure (HF) due to dilated cardiomyopathy (DCM) is a complex syndrome in which numerous cellular, mechanical and flow processes/interactions become deranged. Insights into derangement of left ventricular intra-cardiac flow patterns and kinetic energy (KE) are now afforded by the use of 4D flow CMR. Previous studies have found derangements of intra-ventricular flow components and KE within DCM patients compared to healthy volunteers. Hypothesis: We hypothesised that increasing derangement in 4D flow measures would relate to: 1) decreased mechanical cardiac function, as assessed by myocardial strain, 2) increased levels of biochemical remodelling markers and 3) worsening patient symptoms and functional capacity. Methods: 26 idiopathic DCM patients (69% male, mean age 55±2 yr, LVEF 35±2%) and 10 controls (70% male, mean age 57±4yr, LVEF 68±1.2%) were assessed with 3T CMR. Results: The LV volume was divided into 4 functional components; direct flow (DF), delayed ejection flow (DEF), retained inflow (RI) and residual volume (RV). Compared to controls DCM’s had significantly decreased DF (11±1% vs 38±2%) and increased RV (51±2% vs 31±1%) (fig a). The KE at end diastole differed significantly for all flow components between groups (fig b). Circumferential strain was significantly impaired in DCM’s vs controls (-9.9±0.8% vs -19.7±0.5%, p<0.0001). DF KE correlated positively to the 6 minute walk test (6MWT) and strain, and negatively to the Minnesota HF questionnaire and BNP (fig c). Conclusions: DCM patients demonstrated less efficient blood flow patterns and deranged KE profiles. The greater the derangement of flow parameters from normal, the worse the myocardial strain, BNP, 6MWT and patient symptoms. This study suggests that flow parameter derangements are novel biomarkers of disease severity in DCM, correlating with established markers of prognosis such as BNP and 6MWT and may become useful in monitoring novel therapies and predicting prognosis.


2021 ◽  
Author(s):  
T. Cvitkovic ◽  
A. Horke ◽  
M. Avsar ◽  
D. Bobylev ◽  
P. Beerbaum ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document