scholarly journals Impact of Age and Diastolic Function on Novel, 4D flow CMR Biomarkers of Left Ventricular Blood Flow Kinetic Energy

2018 ◽  
Vol 8 (1) ◽  
Author(s):  
Saul Crandon ◽  
Jos J. M. Westenberg ◽  
Peter P. Swoboda ◽  
Graham J. Fent ◽  
James R. J. Foley ◽  
...  
2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Ciaran Grafton-Clarke ◽  
Saul Crandon ◽  
Jos J. M. Westenberg ◽  
Peter P. Swoboda ◽  
John P. Greenwood ◽  
...  

Abstract Objectives Four-dimensional flow CMR allows for a comprehensive assessment of the blood flow kinetic energy of the ventricles of the heart. In comparison to standard two-dimensional image acquisition, 4D flow CMR is felt to offer superior reproducibility, which is important when repeated examinations may be required. The objective was to evaluate the inter-observer and intra-observer reproducibility of blood flow kinetic energy assessment using 4D flow of the left ventricle in 20 healthy volunteers across two centres in the United Kingdom and the Netherlands. Data description This dataset contains 4D flow CMR blood flow kinetic energy data for 20 healthy volunteers with no known cardiovascular disease. Presented is kinetic energy data for the entire cardiac cycle (global), the systolic and diastolic components, in addition to blood flow kinetic energy for both early and late diastolic filling. This data is available for reuse and would be valuable in supporting other research, such as allowing for larger sample sizes with more statistical power for further analysis of these variables.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Victoria Stoll ◽  
Aaron Hess ◽  
Eylem Levelt ◽  
Jonatan Eriksson ◽  
Petter Dyverfeldt ◽  
...  

Introduction: Heart failure (HF) due to dilated cardiomyopathy (DCM) is a complex syndrome in which numerous cellular, mechanical and flow processes/interactions become deranged. Insights into derangement of left ventricular intra-cardiac flow patterns and kinetic energy (KE) are now afforded by the use of 4D flow CMR. Previous studies have found derangements of intra-ventricular flow components and KE within DCM patients compared to healthy volunteers. Hypothesis: We hypothesised that increasing derangement in 4D flow measures would relate to: 1) decreased mechanical cardiac function, as assessed by myocardial strain, 2) increased levels of biochemical remodelling markers and 3) worsening patient symptoms and functional capacity. Methods: 26 idiopathic DCM patients (69% male, mean age 55±2 yr, LVEF 35±2%) and 10 controls (70% male, mean age 57±4yr, LVEF 68±1.2%) were assessed with 3T CMR. Results: The LV volume was divided into 4 functional components; direct flow (DF), delayed ejection flow (DEF), retained inflow (RI) and residual volume (RV). Compared to controls DCM’s had significantly decreased DF (11±1% vs 38±2%) and increased RV (51±2% vs 31±1%) (fig a). The KE at end diastole differed significantly for all flow components between groups (fig b). Circumferential strain was significantly impaired in DCM’s vs controls (-9.9±0.8% vs -19.7±0.5%, p<0.0001). DF KE correlated positively to the 6 minute walk test (6MWT) and strain, and negatively to the Minnesota HF questionnaire and BNP (fig c). Conclusions: DCM patients demonstrated less efficient blood flow patterns and deranged KE profiles. The greater the derangement of flow parameters from normal, the worse the myocardial strain, BNP, 6MWT and patient symptoms. This study suggests that flow parameter derangements are novel biomarkers of disease severity in DCM, correlating with established markers of prognosis such as BNP and 6MWT and may become useful in monitoring novel therapies and predicting prognosis.


2016 ◽  
Vol 18 (S1) ◽  
Author(s):  
Jakub Zajac ◽  
Jonatan Eriksson ◽  
Petter Dyverfeldt ◽  
Urban Alehagen ◽  
Tino Ebbers ◽  
...  

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Natasha Barker ◽  
Hamza Zafar ◽  
Benjamin Fidock ◽  
Alaa Elhawaz ◽  
Abdallah Al-Mohammad ◽  
...  

2020 ◽  
Vol 7 (3) ◽  
pp. 37
Author(s):  
Harjinder Kaur ◽  
Hosamadin Assadi ◽  
Samer Alabed ◽  
Donnie Cameron ◽  
Vassilios S. Vassiliou ◽  
...  

Background: There is an emerging body of evidence that supports the potential clinical value of left ventricular (LV) intracavity blood flow kinetic energy (KE) assessment using four-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR). The aim of this systematic review is to summarize studies evaluating LV intracavity blood flow KE quantification methods and its potential clinical significance. Methods: A systematic review search was carried out on Medline, Pubmed, EMBASE and CINAHL. Results: Of the 677 articles screened, 16 studies met eligibility. These included six (37%) studies on LV diastolic function, another six (37%) studies on heart failure or cardiomyopathies, three (19%) studies on ischemic heart disease or myocardial infarction and finally, one (6%) study on valvular heart disease, namely, mitral regurgitation. One of the main strengths identified by these studies is high reproducibility of LV blood flow KE hemodynamic assessment (mean coefficient of variability = 6 ±  2%) for the evaluation of LV diastolic function. Conclusions: The evidence gathered in this systematic review suggests that LV blood flow KE has great promise for LV hemodynamic assessment. Studies showed increased diagnostic confidence at no cost of additional time. Results were highly reproducible with low intraobserver variability.


2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Ryan J. Pewowaruk ◽  
Gregory P. Barton ◽  
Cody Johnson ◽  
J. Carter Ralphe ◽  
Christopher J. Francois ◽  
...  

Abstract Background Branch pulmonary artery (PA) stenosis (PAS) commonly occurs in patients with congenital heart disease (CHD). Prior studies have documented technical success and clinical outcomes of PA stent interventions for PAS but the impact of PA stent interventions on ventricular function is unknown. The objective of this study was to utilize 4D flow cardiovascular magnetic resonance (CMR) to better understand the impact of PAS and PA stenting on ventricular contraction and ventricular flow in a swine model of unilateral branch PA stenosis. Methods 18 swine (4 sham, 4 untreated left PAS, 10 PAS stent intervention) underwent right heart catheterization and CMR at 20 weeks age (55 kg). CMR included ventricular strain analysis and 4D flow CMR. Results 4D flow CMR measured inefficient right ventricular (RV) and left ventricular (LV) flow patterns in the PAS group (RV non-dimensional (n.d.) vorticity: sham 82 ± 47, PAS 120 ± 47; LV n.d. vorticity: sham 57 ± 5, PAS 78 ± 15 p < 0.01) despite the PAS group having normal heart rate, ejection fraction and end-diastolic volume. The intervention group demonstrated increased ejection fraction that resulted in more efficient ventricular flow compared to untreated PAS (RV n.d. vorticity: 59 ± 12 p < 0.01; LV n.d. vorticity: 41 ± 7 p < 0.001). Conclusion These results describe previously unknown consequences of PAS on ventricular function in an animal model of unilateral PA stenosis and show that PA stent interventions improve ventricular flow efficiency. This study also highlights the sensitivity of 4D flow CMR biomarkers to detect earlier ventricular dysfunction assisting in identification of patients who may benefit from PAS interventions.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
H Ben-Arzi ◽  
A Das ◽  
C Kelly ◽  
RJ Van Der Geest ◽  
A Chowdhary ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Foundation. Main funding source(s): British Heart Foundation HRUK Background. Four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR) imaging provides quantification of intra-cavity left ventricular (LV) flow kinetic energy (KE) parameters in three dimensions. Myocardial infarction (MI) is known to cause acute alterations in intra-cardiac blood flow but assessments of longitudinal changes are lacking. Purpose. Assess longitudinal changes in LV flow post ST-elevation myocardial infarction (STEMI). Method. Twenty acutely reperfused STEMI patients (13 men, 7 women, mean age 54 ± 9 years) underwent 3T CMR acutely (within 5-7 days) and 3 months post-MI.  CMR protocol included functional imaging, late gadolinium enhancement and 4D flow. Using Q-MASS, LV KE parameters were derived and indexed to LV end-diastolic volume (LVKEiEDV). Based on acute ejection fraction (EF), patients were grouped as follows: preserved (pEF) EF &gt;50%, reduced (rEF) EF &lt;50% including mild (rEF= 40-49%), moderate to severe (EF &lt;40%) impairment.  Results. Out of 20 patients, 13 had rEF acutely (7 mild rEF, 6 moderate to severe rEF). Acute LVKEiEDV parameters varied significantly between pEF and rEF (Table). At 3 months, pEF and mild rEF patients showed a significant (P &lt; 0.05) reduction in average, systolic and peak-A wave LVKEiEDV. Mild rEF patients also had significant (P &lt; 0.05) reduction in minimal and peak-E wave LVKEiEDV. However in patients with moderate to severe rEF in the acute scan, there were no significant change by 3 months (Figure). Conclusion. Following MI, 4D flow LVKE derived biomarkers significantly decreased over time in pEF and mild rEF groups but not in moderate to severe rEF group. 4D flow assessment might provide incremental prognostic value beyond EF assessment alone. Table pEF (n = 7) rEF (n = 13) V1 V2 P-value V1 V2 P-value EF(%) 56 ± 5 55 ± 4 0.40 41 ± 7 47 ± 9 0.01 Infarct Size(%) 31 ± 20 15 ± 9 0.04 18 ± 13† 16 ± 11 0.41 LV KEiEDV parameters Average(µJ/ml) 9 ± 2 7 ± 2 0.02 10 ± 3† 8 ± 3 0.01 Minimal(µJ/ml) 1 ± 0.6 1 ± 0.5 0.46 1.3 ± 0.5 1 ± 0.6 0.03 Systolic(µJ/ml) 10 ± 4 7 ± 2 &lt;0.01 12 ± 4† 7 ± 3 &lt;0.01 Diastolic(µJ/ml) 8 ± 3 7 ± 2 0.13 9 ± 3 8 ± 3 0.09 Peak-E wave(µJ/ml) 22 ± 9 23 ± 8 0.44 20 ± 7 18 ± 10 0.23 Peak-A wave(µJ/ml) 18 ± 10 11 ± 4 0.04 17 ± 9 14 ± 7 0.02 †P &lt; 0.05 V1 comparison between pEF and rEF Abstract Figure