scholarly journals From signal-based to comprehensive magnetic resonance imaging

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Gyula Kotek ◽  
Laura Nunez-Gonzalez ◽  
Mika W. Vogel ◽  
Gabriel P. Krestin ◽  
Dirk H. J. Poot ◽  
...  

AbstractWe present and evaluate a new insight into magnetic resonance imaging (MRI). It is based on the algebraic description of the magnetization during the transient response—including intrinsic magnetic resonance parameters such as longitudinal and transverse relaxation times (T1, T2) and proton density (PD) and experimental conditions such as radiofrequency field (B1) and constant/homogeneous magnetic field (B0) from associated scanners. We exploit the correspondence among three different elements: the signal evolution as a result of a repetitive sequence of blocks of radiofrequency excitation pulses and encoding gradients, the continuous Bloch equations and the mathematical description of a sequence as a linear system. This approach simultaneously provides, in a single measurement, all quantitative parameters of interest as well as associated system imperfections. Finally, we demonstrate the in-vivo applicability of the new concept on a clinical MRI scanner.

2005 ◽  
Vol 2 (2) ◽  
pp. 133-140 ◽  
Author(s):  
D. Mietchen ◽  
H. Keupp ◽  
B. Manz ◽  
F. Volke

Abstract. For more than a decade, Magnetic Resonance Imaging (MRI) has been routinely employed in clinical diagnostics because it allows non-invasive studies of anatomical structures and physiological processes in vivo and to differentiate between healthy and pathological states, particularly of soft tissue. Here, we demonstrate that MRI can likewise be applied to fossilized biological samples and help in elucidating paleopathological and paleoecological questions: Five anomalous guards of Jurassic and Cretaceous belemnites are presented along with putative paleopathological diagnoses directly derived from 3D MR images with microscopic resolution. Syn vivo deformities of both the mineralized internal rostrum and the surrounding former soft tissue can be traced back in part to traumatic events of predator-prey-interactions, and partly to parasitism. Besides, evidence is presented that the frequently observed anomalous apical collar might be indicative of an inflammatory disease. These findings highlight the potential of Magnetic Resonance techniques for further paleontological applications.


2021 ◽  
Vol 10 (11) ◽  
pp. 2461
Author(s):  
José María Mora-Gutiérrez ◽  
María A. Fernández-Seara ◽  
Rebeca Echeverria-Chasco ◽  
Nuria Garcia-Fernandez

Renal magnetic resonance imaging (MRI) techniques are currently in vogue, as they provide in vivo information on renal volume, function, metabolism, perfusion, oxygenation, and microstructural alterations, without the need for exogenous contrast media. New imaging biomarkers can be identified using these tools, which represent a major advance in the understanding and study of the different pathologies affecting the kidney. Diabetic kidney disease (DKD) is one of the most important diseases worldwide due to its high prevalence and impact on public health. However, its multifactorial etiology poses a challenge for both basic and clinical research. Therefore, the use of novel renal MRI techniques is an attractive step forward in the comprehension of DKD, both in its pathogenesis and in its detection and surveillance in the clinical practice. This review article outlines the most promising MRI techniques in the study of DKD, with the purpose of stimulating their clinical translation as possible tools for the diagnosis, follow-up, and monitoring of the clinical impacts of new DKD treatments.


2017 ◽  
Vol 8 (34) ◽  
pp. 5157-5166 ◽  
Author(s):  
A. V. Fuchs ◽  
A. P. Bapat ◽  
G. J. Cowin ◽  
K. J. Thurecht

A switchable polymeric 19F magnetic resonance imaging (MRI) contrast agent was synthesised whereby the transverse (T2) relaxation times increased as a therapeutic was released from a hyperbranched polymer (HBP) scaffold.


1999 ◽  
Vol 24 (2) ◽  
pp. 245-248 ◽  
Author(s):  
T. NAKAMURA ◽  
Y. YABE ◽  
Y. HORIUCHI

In vivo dynamic changes in the interosseous membrane (IOM) during forearm rotation were studied using magnetic resonance imaging (MRI). The right forearms of 20 healthy volunteers were examined in five different rotational positions. Axial slices were obtained at the proximal quarter, the middle and the distal quarter of the forearm. The changes in shape of the IOM during rotation were observed in an axial MR plane. For each image, we measured the interosseous distance and the length of the interosseous membrane. Images of the tendinous and membranous parts of the IOM could be differentiated by thickness. There were minimal dynamic changes in the tendinous part on the MRI while the membranous part showed numerous changes during rotation. The interosseous distance and the length of the interosseous membrane were maximum from a neutral to a slightly supinated position. The tendinous part is considered to be taut during rotation to provide stability between the radius and the ulna, but the membranous part which is soft, thin and elastic, allows smooth rotation.


2013 ◽  
Vol 284-287 ◽  
pp. 1552-1558
Author(s):  
Jen Fang Yu ◽  
Kun Che Lee

This research aims to characterize the geometry of the human cochlear spiral in vivo by measuring curvature and length. Magnetic resonance imaging (MRI) was used to visualise the human inner ear in vivo. The inner ear was imaged in 12 ears in 7 subjects recruited. Visualisation of the cochlear spiral was enhanced by T2 weighting and further processing of the raw images. The spirals were divided into 3 segments: the basal turn segment, the middle turn segment and the apex turn segment. The length and curvature of each segment were measured. The measured lengths of cochlear spiral are consistent with data in the literature derived from anatomical dissections. Overall, the apex turn segment of the cochlear had the greatest degree of curvature. A detailed description of the cochlear spiral is provided, using measurements of curvature and length. This data will provide a valuable reference in the development of cochlear implantation procedures.


2020 ◽  
Vol 11 ◽  
pp. 1000-1009
Author(s):  
Miao Qin ◽  
Yueyou Peng ◽  
Mengjie Xu ◽  
Hui Yan ◽  
Yizhu Cheng ◽  
...  

The multimodal magnetic resonance imaging (MRI) technique has been extensively studied over the past few years since it offers complementary information that can increase diagnostic accuracy. Simple methods to synthesize contrast agents are necessary for the development of multimodal MRI. Herein, uniformly distributed Fe3O4/Gd2O3 nanocubes for T 1–T 2 dual-mode MRI contrast agents were successfully designed and synthesized. In order to increase hydrophilicity and biocompatibility, the nanocubes were coated with nontoxic 3,4-dihydroxyhydrocinnamic acid (DHCA). The results show that iron (Fe) and gadolinium (Gd) were homogeneously distributed throughout the Fe3O4/Gd2O3-DHCA (FGDA) nanocubes. Relaxation time analysis was performed on the images obtained from the 3.0 T scanner. The results demonstrated that r 1 and r 2 maximum values were 67.57 ± 6.2 and 24.2 ± 1.46 mM−1·s−1, respectively. In vivo T 1- and T 2-weighted images showed that FGDA nanocubes act as a dual-mode contrast agent enhancing MRI quality. Overall, these experimental results suggest that the FGDA nanocubes are interesting tools that can be used to increase MRI quality, enabling accurate clinical diagnostics.


Sign in / Sign up

Export Citation Format

Share Document