Direct determination of single-to-double stranded DNA ratio in solution applying time-resolved fluorescence measurements of dye–DNA complexes

2000 ◽  
pp. 689-690 ◽  
Author(s):  
G. Cosa ◽  
K.-S. Focsaneanu ◽  
J. C. Scaiano ◽  
J. R. N. McLean
2021 ◽  
Vol 188 (12) ◽  
Author(s):  
Lifang Gao ◽  
Xu Zhang ◽  
Runlin Yang ◽  
Zhongwei Lv ◽  
Wenge Yang ◽  
...  

1988 ◽  
Vol 34 (8) ◽  
pp. 1640-1644 ◽  
Author(s):  
M J Khosravi ◽  
R C Morton ◽  
E P Diamandis

Abstract In this new immunofluorometric method for quantification of lutropin in serum, the "sandwich" principle is combined with time-resolved fluorescence measurements, with the europium chelate 4,7-bis(chlorosulfophenyl)-1,10-phenanthroline-2,9-dicarboxylic acid (BCPDA) used as label. A monoclonal antibody to the alpha-subunit of lutropin is adsorbed onto the walls of white-opaque microtiter wells to form the solid-phase capture antibody, and a biotin-labeled soluble monoclonal antibody is used for antigen quantification. The detection system is completed with streptavidin, which has been linked to a protein bulking agent labeled with multiple BCPDA residues. In the presence of excess europium, the fluorescence of the final complex attached to captured lutropin molecules is measured on the dried solid phasse with an automated time-resolved fluorometer. The assay can be performed as a rapid (less than 60 min incubation) or regular (150 min incubation) procedure. The rapid assay is well-suited for routine daily monitoring of increasing or ovulatory lutropin concentrations; the regular assay, with its greater sensitivity (0.5 int. unit/L), is a practical procedure for lutropin measurements in hyposecretory states. The assay measures up to 240 int. units/L, and results compare well with those by a commercially available radioimmunoassay, an immunoradiometric assay, and another time-resolved immunofluorometric procedure.


2009 ◽  
Vol 2009 ◽  
pp. 1-14
Author(s):  
Xihong Wu ◽  
J. A. Merten ◽  
N. Omenetto ◽  
B. W. Smith ◽  
J. D. Winefordner

This paper describes the experimental realization and characterization of a versatile single particle detection apparatus. The system utilizes a novel particle beam inlet that can serve as either an on-line particle concentrator (i.e., all diameters confined in a narrow beam) or as a segregator (i.e., selected diameters confined in a narrow beam) and can be operated in a high-speed mode as well as in a low-speed mode, thus allowing different interaction times between the particles and the laser beam. An aerodynamic sizing technique has been incorporated into the system to provide rapid, real-time, and high-resolution sizing. Parameters such as transmission efficiency and size-segregation efficiency have been measured. The performance of the instrument has been demonstrated by on-line detection of spectrally resolved and time resolved fluorescence detection from airborne dye-doped particles and aerosolized endogenous fluorophores found in biological agents.


Sign in / Sign up

Export Citation Format

Share Document