Towards high concentration enhancement of microfluidic temperature gradient focusing of sample solutes using combined AC and DC field induced Joule heating

Lab on a Chip ◽  
2011 ◽  
Vol 11 (7) ◽  
pp. 1396 ◽  
Author(s):  
Zhengwei Ge ◽  
Wei Wang ◽  
Chun Yang
Author(s):  
Zhengwei Ge ◽  
Chun Yang

This paper reports an improved technique to enhance microfluidic temperature gradient focusing (TGF) of sample solutes using Joule heating effects induced by a combined AC and DC electric field. By introducing the AC field component, additional Joule heating effects are obtained to generate temperature gradient for concentrating sample solutes, while the electroosmotic flow is suppressed under the high frequency AC electric field. Therefore, the required DC voltages for achieving certain sample concentration by Joule heating induced TGF technique are remarkably reduced. Moreover, the lower DC voltages lead to smaller electroosmotic flow (EOF), thereby reducing the backpressure effects due to the finite reservoir size. Concentration enhancements of sample solutes are improved by using a combined AC and DC electric field.


Author(s):  
Zhengwei Ge ◽  
Chun Yang

Microfluidic concentration of sample species is achieved using the temperature gradient focusing (TGF) in a microchannel with a step change in the cross-section under a pure direct current (DC) field or a combined alternating current (AC) and DC electric field. Experiments were carried out to study the effects of applied voltage, buffer concentration and channel size on sample concentration in the TGF processes. These effects were analyzed and summarized using a dimensionless Joule number that is introduced in this study. In addition, Joule number effect in the Poly-dimethylsiloxane (PDMS)/PDMS microdevice was compared with the PDMS/Glass microdevice. A more than 450-fold concentration enhancement was obtained within 75 seconds in the PDMS/PDMS microdevice. Results also showed that the high frequency AC electric field which contributes to produce the temperature gradient and reduces the required DC voltage for the sample concentration. The lower DC voltage has generated slower electroosmotic flow (EOF), which reduces the backpressure effect associated with the finite reservoir size. Finally, a more than 2500-fold concentration enhancement was obtained within 14 minutes in the PDMS/PDMS microdevice, which was a great achievement in this TGF technique using inherent Joule heating effects.


Author(s):  
Amitava Dutta ◽  
Apurba Kumar Santra ◽  
Ranjan Ganguly

Abstract We present a detailed numerical analysis of electrophoresis induced concentration of a bio-analyte facilitated by temperature gradient focusing in a phosphate buffer solution via Joule heating inside a converging-diverging microchannel. The purpose is to study the effects of frequency of AC field and channel width variation on the concentration of target analyte. We tune the buffer viscosity, conductivity and electrophoretic mobility of the analyte such that the electrophoretic velocity of the analyte locally balances the electroosmotic flow of the buffer, resulting in a local build-up of the analyte concentration in a target region. An AC field is superimposed on the applied DC field within the microchannel in such a way that the back pressure effect is minimized, resulting in minimum dispersion and high concentration of the target analyte. Axial transport of fluorescein-Na in the phosphate buffer solution is controlled by inducing temperature gradient through Joule heating. The technique leverages the fact that the buffer's ionic strength and viscosity depends on temperature, which in turn guides the analyte transport. A numerical model is proposed and a finite element-based solution of the coupled electric field, mass, momentum, energy and species equations are carried out. Simulation predict peak of 670-fold concentration of fluorescein-Na is achieved. The peak concentration is found to increase sharply as the channel throat width, while the axial spread of concentrated analyte increases at lower frequency of AC field. The results of the work may improve the design of micro concentrator.


Author(s):  
Gong Yue Tang ◽  
Chun Yang

Temperature gradient focusing is a recently developed technique for spatially focusing and separating ionic analytes in microchannels. The temperature gradient required for temperature gradient focusing can be generated either by an imposed temperature gradient or by Joule heating resulted from an applied electric field that also drives buffer flow. In this study, a numerical model describing the Joule heating induced temperature development and temperature gradient focusing is developed. The model consists of a set of governing equations including the Poisson-Boltzmann equation, the Laplace equation, the Navier-Stokes equations, the energy equations and the mass transport equation. As the thermophysical and electrical properties including the liquid dielectric constant, viscosity and electric conductivity are temperature-dependent, these governing equations are coupled, and therefore the coupled governing equations are solved numerically by using a CFD based numerical method. The numerical simulations agree well with the experimental results, suggesting that the valid mathematical model presented in this study.


Author(s):  
Zhengwei Ge ◽  
Chun Yang

Microfluidic concentration is achieved by utilizing Joule heating effect induced temperature gradient focusing (TGF) under a combined AC and DC electric field imposed in a straight microchannel with sudden expansion in cross-section. The introduction of AC electric field component services dual functions: one is to produce Joule heating effects for generating temperature gradient, and the other is to suppress electroosmotic flow with high frequencies. Therefore, the required DC voltage for achieving sample concentration with Joule heating induced TGF technique is remarkably reduced. The lower DC voltage can lead to smaller electroosmotic flow (EOF), thereby reducing the backpressure effect due to the finite reservoir size. It was demonstrated that using the proposed new TGF technique with Joule heating effect under a combined AC and DC field, more than 2500-fold concentration enhancement was obtained within 14 minutes in a PDMS/PDMS microdevice, which is an order of magnitude higher than the literature reported concentration enhancement achieved by microfluidic devices utilizing the Joule heating induced TGF technique.


2006 ◽  
Vol 78 (23) ◽  
pp. 8028-8035 ◽  
Author(s):  
Sun Min Kim ◽  
Greg J. Sommer ◽  
Mark A. Burns ◽  
Ernest F. Hasselbrink

Lab on a Chip ◽  
2007 ◽  
Vol 7 (7) ◽  
pp. 898 ◽  
Author(s):  
Greg J. Sommer ◽  
Sun Min Kim ◽  
Robert J. Littrell ◽  
Ernest F. Hasselbrink

Sign in / Sign up

Export Citation Format

Share Document