Microfluidic concentration enhancement of bio-analyte by temperature gradient focusing via Joule heating by DC plus AC field: A numerical approach

Author(s):  
Amitava Dutta ◽  
Apurba Kumar Santra ◽  
Ranjan Ganguly

Abstract We present a detailed numerical analysis of electrophoresis induced concentration of a bio-analyte facilitated by temperature gradient focusing in a phosphate buffer solution via Joule heating inside a converging-diverging microchannel. The purpose is to study the effects of frequency of AC field and channel width variation on the concentration of target analyte. We tune the buffer viscosity, conductivity and electrophoretic mobility of the analyte such that the electrophoretic velocity of the analyte locally balances the electroosmotic flow of the buffer, resulting in a local build-up of the analyte concentration in a target region. An AC field is superimposed on the applied DC field within the microchannel in such a way that the back pressure effect is minimized, resulting in minimum dispersion and high concentration of the target analyte. Axial transport of fluorescein-Na in the phosphate buffer solution is controlled by inducing temperature gradient through Joule heating. The technique leverages the fact that the buffer's ionic strength and viscosity depends on temperature, which in turn guides the analyte transport. A numerical model is proposed and a finite element-based solution of the coupled electric field, mass, momentum, energy and species equations are carried out. Simulation predict peak of 670-fold concentration of fluorescein-Na is achieved. The peak concentration is found to increase sharply as the channel throat width, while the axial spread of concentrated analyte increases at lower frequency of AC field. The results of the work may improve the design of micro concentrator.

Author(s):  
Zhengwei Ge ◽  
Chun Yang

This paper reports an improved technique to enhance microfluidic temperature gradient focusing (TGF) of sample solutes using Joule heating effects induced by a combined AC and DC electric field. By introducing the AC field component, additional Joule heating effects are obtained to generate temperature gradient for concentrating sample solutes, while the electroosmotic flow is suppressed under the high frequency AC electric field. Therefore, the required DC voltages for achieving certain sample concentration by Joule heating induced TGF technique are remarkably reduced. Moreover, the lower DC voltages lead to smaller electroosmotic flow (EOF), thereby reducing the backpressure effects due to the finite reservoir size. Concentration enhancements of sample solutes are improved by using a combined AC and DC electric field.


2011 ◽  
Vol 284-286 ◽  
pp. 1764-1769 ◽  
Author(s):  
Vitalijs Lakevics ◽  
Janis Locs ◽  
Dagnija Loca ◽  
Valentina Stepanova ◽  
Liga Berzina-Cimdina ◽  
...  

Sorption experiments of bovine serum albumin (BSA) on hydroxyapatite (HAp) ceramic granules, prepared at three temperatures 900°C, 1000°C and 1150°C were performed at room temperature 18,6 °C and phosphate buffer, pH 5,83; 6.38 and 7,39. Thermal treatment contributed to the decrease of bovine serum albumin immobilization indicating that sorption process depended on HAp ceramics specific surface area and pH values of phosphate buffer solution. However, it was confirmed that granule size was also an important parameter for bovine serum albumin adsorption. As a result of these experiments, the most appropriate adsorption conditions and phosphate buffer pH values influence on to BSA sorption were analyzed.


Author(s):  
Zhengwei Ge ◽  
Chun Yang

Microfluidic concentration of sample species is achieved using the temperature gradient focusing (TGF) in a microchannel with a step change in the cross-section under a pure direct current (DC) field or a combined alternating current (AC) and DC electric field. Experiments were carried out to study the effects of applied voltage, buffer concentration and channel size on sample concentration in the TGF processes. These effects were analyzed and summarized using a dimensionless Joule number that is introduced in this study. In addition, Joule number effect in the Poly-dimethylsiloxane (PDMS)/PDMS microdevice was compared with the PDMS/Glass microdevice. A more than 450-fold concentration enhancement was obtained within 75 seconds in the PDMS/PDMS microdevice. Results also showed that the high frequency AC electric field which contributes to produce the temperature gradient and reduces the required DC voltage for the sample concentration. The lower DC voltage has generated slower electroosmotic flow (EOF), which reduces the backpressure effect associated with the finite reservoir size. Finally, a more than 2500-fold concentration enhancement was obtained within 14 minutes in the PDMS/PDMS microdevice, which was a great achievement in this TGF technique using inherent Joule heating effects.


2000 ◽  
Vol 63 (6) ◽  
pp. 703-708 ◽  
Author(s):  
MARCY A. WISNIEWSKY ◽  
BONITA A. GLATZ ◽  
MARK L. GLEASON ◽  
CHERYLL A. REITMEIER

The objectives of this study were to determine if washing of whole apples with solutions of three different sanitizers (peroxyacetic acid, chlorine dioxide, or a chlorine-phosphate buffer solution) could reduce a contaminating nonpathogenic Escherichia coli O157:H7 population by 5 logs and at what sanitizer concentration and wash time such a reduction could be achieved. Sanitizers were tested at 1, 2, 4, 8, and 16 times the manufacturer's recommended concentration at wash times of 5, 10, and 15 min. Whole, sound Braeburn apples were inoculated with approximately 1 × 108 or 7 × 106 CFU per apple, stored for 24 h, then washed with sterile water (control) or with sanitizers for the prescribed time. Recovered bacteria were enumerated on trypticase soy agar. Washing with water alone reduced the recoverable population by almost 2 logs from the starting population; this can be attributed to physical removal of organisms from the apple surface. No sanitizer, when used at the recommended concentration, reduced the recovered E. coli population by 5 logs under the test conditions. The most effective sanitizer, peroxyacetic acid, achieved a 5-log reduction when used at 2.1 to 14 times its recommended concentration, depending on the length of the wash time. The chlorine-phosphate buffer solution reduced the population by 5 logs when used at 3 to 15 times its recommended concentration, depending on wash time. At no concentration or wash time tested did chlorine dioxide achieve the 5-log reduction.


2018 ◽  
Vol 10 (11) ◽  
pp. 1362-1371 ◽  
Author(s):  
Mallappa Mahanthappa ◽  
Nagaraju Kottam ◽  
Shivaraj Yellappa

The simultaneous electroanalysis of acetaminophen (AC), guanine (G) and adenine (A) was successfully achieved on the zinc sulphide nanoparticles-modified carbon paste electrode (ZnS NPs/CPE) in phosphate buffer solution (PBS).


2018 ◽  
Vol 5 (1) ◽  
pp. 1 ◽  
Author(s):  
Jessica Oliveira ◽  
Raquel Rodrigues ◽  
Lillian Barros ◽  
Isabel Ferreira ◽  
Luís Marchesi ◽  
...  

In this study, hydrophilic magnetic nanoparticles were synthesized by green routes using a methanolic extract of Rubus ulmifolius Schott flowers. The prepared magnetic nanoparticles were coated with carbon-based shell for drug delivery application. The nanocomposites were further chemically functionalized with nitric acid and, sequentially, with Pluronic® F68 (CMNPs-plur) to enhance their colloidal stability. The resulting material was dispersed in phosphate buffer solution at pH 7.4 to study the Doxorubicin loading. After shaking for 48 h, 99.13% of the drug was loaded by the nanocomposites. Subsequently, the drug release was studied in different working phosphate buffer solutions (i.e., PB pH 4.5, pH 6.0 and pH 7.4) to determine the efficiency of the synthesized material for drug delivery as pH-dependent drug nanocarrier. The results have shown a drug release quantity 18% higher in mimicking tumor environment than in the physiological one. Therefore, this study demonstrates the ability of CMNPs-plur to release a drug with pH dependence, which could be used in the future for the treatment of cancer "in situ" by means of controlled drug release.


1950 ◽  
Vol 91 (6) ◽  
pp. 655-664 ◽  
Author(s):  
Armin F. Schick ◽  
George M. Hass

A new method for the isolation of large numbers of individual myofibrils from fresh mammalian skeletal and cardiac muscle has been described. Purification of isolated myofibrils was accomplished by differential centrifugation of fresh frozen sections of muscle which had been mechanically agitated after exposure for 30 to 45 minutes at 0°C. to the action of a dilute solution of trypsin in a phosphate buffer solution with a pH of 7.0 and an ionic strength of 0.25. Isolated skeletal myofibrils of the rabbit and man have similar constant solubility properties. They dissolve in an aqueous mixture of 0.5 N potassium chloride and 0.03 N sodium bicarbonate, giving viscous solutions which exhibit conspicuous birefringence of flow. They are soluble in buffer solutions (ionic strength 0.15) on the acid side of pH 4 and alkaline side of pH 10. If the ionic strength of potassium phosphate buffer solutions is increased to 0.5 or if the ionic strength of phosphate-borate buffer solutions is increased to a similar value by addition of potassium chloride, the isolated myofibrils become soluble at neutrality. Hence, it is possible, first to isolate the myofibrils and then dissolve them without deviating appreciably from physiologic ranges of pH. The extent to which myofibrils are modified by the conditions imposed by the method of isolation is unknown. There is no significant change in microscopic structure or optical birefringence. Furthermore, there is retention of a form of physiological reactivity, for when the isolated skeletal myofibrils are immersed in solutions of adenosinetriphosphate, they promptly and irreversibly change from elongated fibrils with distinct structural detail into dense spherical masses without recognizable microscopic structure.


Sign in / Sign up

Export Citation Format

Share Document