A non-enzymatic sensor for hydrogen peroxide based on polyaniline, multiwalled carbon nanotubes and gold nanoparticles modified Au electrode

The Analyst ◽  
2011 ◽  
Vol 136 (21) ◽  
pp. 4460 ◽  
Author(s):  
Jagriti Narang ◽  
Nidhi Chauhan ◽  
C. S. Pundir
RSC Advances ◽  
2014 ◽  
Vol 4 (80) ◽  
pp. 42723-42731 ◽  
Author(s):  
Bhawna Batra ◽  
C. S. Pundir

We describe the construction of a new enzyme electrode (GluOx/cMWCNT/AuNPs/CHIT/Au) and its application for the amperometric determination of β-ODAP (3-N-oxalyl-L-2,3-diaminopropanoic acid) in Lathyrus seeds.


2020 ◽  
Vol 16 (7) ◽  
pp. 905-913
Author(s):  
Youyuan Peng ◽  
Qingshan Miao

Background: L-Ascorbic acid (AA) is a kind of water soluble vitamin, which is mainly present in fruits, vegetables and biological fluids. As a low cost antioxidant and effective scavenger of free radicals, AA may help to prevent diseases such as cancer and Parkinson’s disease. Owing to its role in the biological metabolism, AA has also been utilized for the therapy of mental illness, common cold and for improving the immunity. Therefore, it is very necessary and urgent to develop a simple, rapid and selective strategy for the detection of AA in various samples. Methods: The molecularly imprinted poly(o-phenylenediamine) (PoPD) film was prepared for the analysis of L-ascorbic acid (AA) on gold nanoparticles (AuNPs) - multiwalled carbon nanotubes (MWCNTs) modified glass carbon electrode (GCE) by electropolymerization of o-phenylenediamine (oPD) and AA. Experimental parameters including pH value of running buffer and scan rates were optimized. Scanning electron microscope (SEM), fourier-transform infrared (FTIR) spectra, cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were utilized for the characterization of the imprinted polymer film. Results: Under the selected experimental conditions, the DPV peak currents of AA exhibit two distinct linear responses ranging from 0.01 to 2 μmol L-1 and 2 to 100 μmol L-1 towards the concentrations of AA, and the detection limit was 2 nmol L-1 (S/N=3). Conclusion: The proposed electrochemical sensor possesses excellent selectivity for AA, along with good reproducibility and stability. The results obtained from the analysis of AA in real samples demonstrated the applicability of the proposed sensor to practical analysis.


Author(s):  
Narasimha Murthy Umesh ◽  
Karuppasamy Kohila rani ◽  
Rajkumar Devasenathipathy ◽  
Balasubramanian Sriram ◽  
Yi-Xin Liu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document