scholarly journals PDMPO: a specific silicon or silica, pH sensitive fluorescent probe?

RSC Advances ◽  
2020 ◽  
Vol 10 (51) ◽  
pp. 31003-31011
Author(s):  
Patricia Merdy ◽  
Cyril Neytard ◽  
Jean-Dominique Meunier ◽  
Yves Lucas

To understand Si behavior in soils and plants, we evaluated the use of PDMPO that was supposed to be a Si-specific, pH-dependent fluorescence marker. We found that the PDMPO fluorescence is neither Si-specific nor pH dependent.

2008 ◽  
Vol 183 (5) ◽  
pp. 865-879 ◽  
Author(s):  
Christian Frantz ◽  
Gabriela Barreiro ◽  
Laura Dominguez ◽  
Xiaoming Chen ◽  
Robert Eddy ◽  
...  

Newly generated actin free barbed ends at the front of motile cells provide sites for actin filament assembly driving membrane protrusion. Growth factors induce a rapid biphasic increase in actin free barbed ends, and we found both phases absent in fibroblasts lacking H+ efflux by the Na-H exchanger NHE1. The first phase is restored by expression of mutant cofilin-H133A but not unphosphorylated cofilin-S3A. Constant pH molecular dynamics simulations and nuclear magnetic resonance (NMR) reveal pH-sensitive structural changes in the cofilin C-terminal filamentous actin binding site dependent on His133. However, cofilin-H133A retains pH-sensitive changes in NMR spectra and severing activity in vitro, which suggests that it has a more complex behavior in cells. Cofilin activity is inhibited by phosphoinositide binding, and we found that phosphoinositide binding is pH-dependent for wild-type cofilin, with decreased binding at a higher pH. In contrast, phosphoinositide binding by cofilin-H133A is attenuated and pH insensitive. These data suggest a molecular mechanism whereby cofilin acts as a pH sensor to mediate a pH-dependent actin filament dynamics.


2021 ◽  
Vol 18 ◽  
Author(s):  
Aykut Elmas ◽  
Guliz Akyuz ◽  
Ayhan Bergal ◽  
Muberra Andac ◽  
Omer Andac

Background: pH sensitive dendrimers attached to nanocarriers, as one of the drug release systems, has become quite popular due to their ease of manufacture in experimental conditions and ability to generate fast drug release in the targeted area. This kind of fast release behavior cannot be represented properly most of the existing kinetic mathematical models. Besides, these models have either no pH dependence or pH dependence added separately. So, they have remained one dimensional. Objective: The aim of this study was to establish the proper analytic equation to describe the fast release of drugs from pH sensitive nanocarrier systems. Then, to combine it with the pH dependent equation for establishing a two-dimensional model for whole system. Methods: We used four common kinetic models for comparison and we fitted them to the release data. Finding that, only Higuchi and Korsmeyer-Peppas models show acceptable fit results. None of these models have pH dependence. To get a better description for pH triggered fast release, we observed the behavior of the slope angle of the release curve. Then we puroposed a new analytic equation by using relation between the slope angle and time. Result: To add a pH dependent equation, we assumed the drug release is “on” or “off” above/below specific pH value and we modified a step function to get a desired behavior. Conclusion: Our new analytic model shows good fitting, not only one-dimensional time dependent release, but also two-dimensional pH dependent release, that provides a useful analytic model to represent release profiles of pH sensitive fast drug release systems.


RSC Advances ◽  
2015 ◽  
Vol 5 (108) ◽  
pp. 89083-89091 ◽  
Author(s):  
Huijuan Zhang ◽  
Xianjuan Pang ◽  
Yuan Qi

A pH-sensitive and mechanically strong graphene oxide/sodium alginate/polyacrylamide nanocomposite semi-IPN hydrogel was designed and prepared. The composite semi-IPN hydrogel showed superior mechanical strength and pH-dependent swelling behavior.


2017 ◽  
Vol 1 (11) ◽  
pp. 2292-2298 ◽  
Author(s):  
Xiao Zhang ◽  
Yongchao Yan ◽  
Qing Peng ◽  
Jian Wang ◽  
Yandi Hang ◽  
...  

The pH-sensitive multifunctional fluorescent probe PNPM based on N-annulated perylene was firstly developed for detecting HOCl selectively. And the probe could detect pH and HOCl simultaneously, and was successfully employed to detect HOCl in serum and water samples.


1992 ◽  
Author(s):  
Serge R. Mordon ◽  
Vincent Maunoury ◽  
Jean-Marie Devoisselle ◽  
Y. Abbas ◽  
Denise Coustaut

Sign in / Sign up

Export Citation Format

Share Document