Non-enzymatic colorimetric detection of hydrogen peroxide using a μPAD coupled with a machine learning-based smartphone app

The Analyst ◽  
2021 ◽  
Author(s):  
Vakkas Doğan ◽  
Elif Yüzer ◽  
Volkan Kilic ◽  
Mustafa Şen

In the present study, iodide-mediated 3,3’,5,5’-tetramethylbenzidine (TMB)-H2O2 reaction system was applied to a microfluidic paper-based analytical device (μPAD) for non-enzymatic colorimetric determination of H2O2. The proposed system is portable and...

1939 ◽  
Vol 11 (9) ◽  
pp. 502-503 ◽  
Author(s):  
Charles A. Peters ◽  
Majel M. MacMasters ◽  
Chester L. French

Talanta ◽  
2019 ◽  
Vol 204 ◽  
pp. 518-524 ◽  
Author(s):  
Qijun Wu ◽  
Jiaqi He ◽  
Hu Meng ◽  
Yu Wang ◽  
Yu Zhang ◽  
...  

1991 ◽  
Vol 74 (1) ◽  
pp. 22-26 ◽  
Author(s):  
David K Christians ◽  
Thomas G Aspelund ◽  
Scott V Brayton ◽  
Larry L Roberts

Abstract Seven laboratories participated In a collaborative study of a method for determination of phosphorus in meat and meat products. Samples are digested In sulfuric acid and hydrogen peroxide; digestion Is complete In approximately 10 mln. Phosphorus Is determined by colorimetric analysis of a dilute aliquot of the sample digest. The collaborators analyzed 3 sets of blind duplicate samples from each of 6 classes of meat (U.S. Department of Agriculture classifications): smoked ham, water-added ham, canned ham, pork sausage, cooked sausage, and hamburger. The calibration curve was linear over the range of standard solutions prepared (phosphorus levels from 0.05 to 1.00%); levels in the collaborative study samples ranged from 0.10 to 0.30%. Standard deviations for repeatability (sr) and reproducibility (sR) ranged from 0.004 to 0.012 and 0.007 to 0.014, respectively. Corresponding relative standard deviations (RSDr and RSDR, respectively) ranged from 1.70 to 7.28% and 3.50 to 9.87%. Six laboratories analyzed samples by both the proposed method and AOAC method 24.016 (14th Ed.). One laboratory reported results by the proposed method only. Statistical evaluations Indicated no significant difference between the 2 methods. The method has been adopted official first action by AOAC.


The Analyst ◽  
2019 ◽  
Vol 144 (8) ◽  
pp. 2716-2724 ◽  
Author(s):  
Zunfu Hu ◽  
Yongheng Yin ◽  
Qingyun Liu ◽  
Xiuwen Zheng

Surface-modified FePt nanoparticles were loaded into metal–organic frameworks in a facile in situ way and the resulting material (FePt@MOFs NCs) acted as a high efficient colorimetric detection agent for H2O2.


Sign in / Sign up

Export Citation Format

Share Document