scholarly journals A novel time-resolved fluorescent lateral flow immunoassay for quantitative detection of the trauma brain injury biomarker-glial fibrillary acidic protein

2022 ◽  
Author(s):  
Satheesh Natarajan ◽  
Jayaraj Joseph

A highly sensitive time-resolved fluorescence lateral flow immunoassay (TRF-LFIA) was developed to quantify glial fibrillary acidic protein (GFAP), a trauma brain injury (TBI) biomarker in blood, for the purpose of providing a diagnosis of mild brain injury.

Author(s):  
Irina Vasilivna Tsyganenko ◽  
Vasil Vasilyovich Simrok ◽  
Katerina Sergiivna Ruban

The present article is concerned with the study of glial fibrillary acidic protein (GFAP) level in the blood serum of pregnant women  with post–trauma brain injury syndrome (post-TBI syndrome) as the marker of  hematoencephalic barrier status and predictor of obstetric and perinatal complications development.


Nanomaterials ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 768
Author(s):  
Hyung-Mo Kim ◽  
Chiwoo Oh ◽  
Jaehyun An ◽  
Seungki Baek ◽  
Sungje Bock ◽  
...  

Exosomes are attracting attention as new biomarkers for monitoring the diagnosis and prognosis of certain diseases. Colorimetric-based lateral-flow assays have been previously used to detect exosomes, but these have the disadvantage of a high limit of detection. Here, we introduce a new technique to improve exosome detection. In our approach, highly bright multi-quantum dots embedded in silica-encapsulated nanoparticles (M–QD–SNs), which have uniform size and are brighter than single quantum dots, were applied to the lateral flow immunoassay method to sensitively detect exosomes. Anti-CD63 antibodies were introduced on the surface of the M–QD–SNs, and a lateral flow immunoassay with the M–QD–SNs was conducted to detect human foreskin fibroblast (HFF) exosomes. Exosome samples included a wide range of concentrations from 100 to 1000 exosomes/µL, and the detection limit of our newly designed system was 117.94 exosome/μL, which was 11 times lower than the previously reported limits. Additionally, exosomes were selectively detected relative to the negative controls, liposomes, and newborn calf serum, confirming that this method prevented non-specific binding. Thus, our study demonstrates that highly sensitive and quantitative exosome detection can be conducted quickly and accurately by using lateral immunochromatographic analysis with M–QD–SNs.


2021 ◽  
Author(s):  
Vasily G. Panferov ◽  
Shyatesa C. Razo ◽  
Irina V. Safenkova ◽  
Anatoly V. Zherdev ◽  
Boris B. Dzantiev

2019 ◽  
Vol 36 (10) ◽  
pp. 1551-1560 ◽  
Author(s):  
Iftakher Hossain ◽  
Mehrbod Mohammadian ◽  
Riikka S.K. Takala ◽  
Olli Tenovuo ◽  
Linnéa Lagerstedt ◽  
...  