Total harmonic distortion reduction add‐on unit for three‐phase diode rectifiers

2016 ◽  
Vol 52 (4) ◽  
pp. 306-308 ◽  
Author(s):  
M. Makoschitz ◽  
M. Hartmann ◽  
H. Ertl
2021 ◽  
Vol 2 (2) ◽  
pp. 29-35
Author(s):  
Dmitry A. Sorokin ◽  
◽  
Sergey I. Volskiy ◽  
Jaroslav Dragoun ◽  
◽  
...  

The paper suggests a control system of a three-phase power factor corrector. The study of the control system operation is carried out and the expressions for calculating the permissible values of error amplifier factors are obtained. The influence of the error amplifier parameters on phase current quality is investigated. The dependence of total harmonic distortion input current on a combination of error amplifier parameters is obtained at a given value of power factor. The conditions under which the total harmonic distortion input current has the minimum value are found out. This article is of interest to power electronics engineers, who are aimed at developing a three-phase power factor corrector.


2014 ◽  
Vol 792 ◽  
pp. 239-244 ◽  
Author(s):  
Koichi Nakaiwa ◽  
Hiroyuki Wakiwaka ◽  
Kunihisa Tashiro

The relation between the Electro Motive Force (EMF) and Total Harmonic Distortion (THD) was compared and verified by magnet arrangement. Using Halbach array, thrust was more increase by change of magnet arrangement. Moreover, the variable trend of cogging and THD by magnet ratio and magnet form change was checked.


Author(s):  
M. H. Yatim ◽  
A. Ponniran ◽  
M. A. Zaini ◽  
M. S. Shaili ◽  
N. A. S. Ngamidun ◽  
...  

The purpose of this study is to analyze the operation and design of symmetrical and asymmetrical multilevel inverter structures with reduced number of switching devices. In this study, the term of conventional inverter is defined as a single cascaded inverter. Specifically, the inverter operates in three complete loops and only produces 2-level and 3-level of output voltages. Usually, cascaded structure suffers from the high total harmonic distortion. Thus, by considering multilevel structure of inverter, low total harmonic distortion reduction and voltage stress reduction on switching devices can be archived. Sinusoidal pulse width modulation and modified square pulse width modulation are used as modulation techniques in switching schemes of the designed multilevel inverters. The findings indicate that, the designed multilevel structure cause low total harmonics distortion at the output voltage. Furthermore, the asymmetrical structure is producing the same output voltage levels with reduced number of switching devices compared to the symmetrical structure is experimentally confirmed. The findings show that the total harmonic distortion for 7-level (symmetrical) and 9-level (asymmetrical) are 16.45% and 15.22%, respectively.