Thermal drift in wavelength-switching DFB and DBR lasers

1997 ◽  
Vol 33 (9) ◽  
pp. 780 ◽  
Author(s):  
A.A. Saavedra ◽  
R. Passy ◽  
J.P. von der Weid
2008 ◽  
Vol 20 (20) ◽  
pp. 1721-1723 ◽  
Author(s):  
Lei Dong ◽  
Ruikang Zhang ◽  
Dingli Wang ◽  
Shan Jiang ◽  
Yonglin Yu ◽  
...  

1995 ◽  
Vol 31 (1) ◽  
pp. 75-81 ◽  
Author(s):  
Lintao Zhang ◽  
J.C. Cartledge

Author(s):  
Louis T. Germinario

A liquid nitrogen stage has been developed for the JEOL JEM-100B electron microscope equipped with a scanning attachment. The design is a modification of the standard JEM-100B SEM specimen holder with specimen cooling to any temperatures In the range ~ 55°K to room temperature. Since the specimen plane is maintained at the ‘high resolution’ focal position of the objective lens and ‘bumping’ and thermal drift la minimized by supercooling the liquid nitrogen, the high resolution capability of the microscope is maintained (Fig.4).


Author(s):  
P.R. Swann ◽  
A.E. Lloyd

Figure 1 shows the design of a specimen stage used for the in situ observation of phase transformations in the temperature range between ambient and −160°C. The design has the following features a high degree of specimen stability during tilting linear tilt actuation about two orthogonal axes for accurate control of tilt angle read-out high angle tilt range for stereo work and habit plane determination simple, robust construction temperature control of better than ±0.5°C minimum thermal drift and transmission of vibration from the cooling system.


2020 ◽  
Vol 16 (7) ◽  
pp. 831-843
Author(s):  
Yuwen Wang ◽  
Shuping Li ◽  
Liuhong Zhang ◽  
Shenglan Qi ◽  
Huida Guan ◽  
...  

Background and Objective: Kang Fu Xin liquid (KFX) is an official preparation made from the ethanol extract product from P. Americana. The present quality control method cannot control the quality of the preparation well. The aim of the present study is to establish a convenient HPLC method for multicomponents determination combined with fingerprint analysis for quality control of KFX. Methods: An HPLC-DAD method with gradient elution and detective wavelength switching program was developed to establish HPLC fingerprints of KFX, and 38 batches of KFX were compared and evaluated by similarity analysis (SA), hierarchical clustering analysis (HCA), and principal component analysis (PCA). Meanwhile, six nucleosides and three amino acids, including uracil, hypoxanthine, uric acid, adenosine, xanthine, inosine, tyrosine, phenylalanine and tryptophan in KFX were determined based on the HPLC fingerprints. Results: An HPLC method assisted with gradient elution and wavelength switching program was established and validated for multicomponents determination combined with fingerprint analysis of KFX. The results demonstrated that the similarity values of the KFX samples were more than 0.845. PCA indicated that peaks 4 (hypoxanthine), 7 (xanthine), 9 (tyrosine), 11, 13 and 17 might be the characteristic contributed components. The nine constituents in KFX, uracil, hypoxanthine, uric acid, adenosine, xanthine, inosine, tyrosine, phenylalanine and tryptophan, showed good regression (R2 > 0.9997) within test ranges and the recoveries of the method for all analytes were in the range from 96.74 to 104.24%. The limits of detections and quantifications for nine constituents in DAD were less than 0.22 and 0.43 μg•mL-1, respectively. Conclusion: The qualitative analysis of chemical fingerprints and the quantitative analysis of multiple indicators provide a powerful and rational way to control the KFX quality for pharmaceutical companies.


Sign in / Sign up

Export Citation Format

Share Document