scholarly journals Condensation of Novec 649 refrigerant in pipe minichannels

2018 ◽  
Vol 70 ◽  
pp. 02002 ◽  
Author(s):  
Tadeusz Bohdal ◽  
Henryk Charun ◽  
Małgorzata Sikora

The paper presents the results of experimental investigation of Novec 649 refrigerant condensation in tube minichannels. This is a low-pressure refrigerant. This investigations are basis for flow structures visualization during condensation in pipe minichannels. The local and the average values of pressure drop (Δp/L) and heat transfer coefficient α in the whole range of the changes of vapour quality (x = 1 ÷ 0) were calculated. On the basis of the obtained test results there was illustrated the influence of the vapour quality x, the mass flux density G and the inner diameter of channel d changes on the studied parameters. These results were compared with the calculation results based on the dependencies of other authors.

2016 ◽  
Vol 37 (2) ◽  
pp. 41-69 ◽  
Author(s):  
Tadeusz Bohdal ◽  
Katarzyna Widomska ◽  
Małgorzata Sikora

Abstract The paper presents the results of experimental heat transfer and pressure drop during condensation of the single component refrigerant R134a and zeotropic mixtures R404A, R407C, and R410A in tube minichannels of internal diameter from the range 0.31-3.30 mm. The local values and the average of heat transfer coefficient and pressure drop in the whole range of the change in mass quality were measured. On the basis of the obtained test results there was illustrated the influence of the change of mass vapor quality, the mass flux density, and the inner diameter of channel on the studied parameters. These results were compared with the calculation results based on the relations postulated by other authors. The discrepancy range was ± 50%. On the basis of given test results own correlation was developed to calculate the heat transfer coefficient and pressure drop of tested refrigerants which presents the obtained results in a range of discrepancy of ±25%.


Author(s):  
Ravindra Kumar ◽  
Parmanand Kumar

In this paper, the multi-objective optimization of R-245fa vapour condensation inside horizontal tube has been carried out using teaching–learning-based optimization algorithm. The teaching–learning-based optimization algorithm is teaching–learning procedure motivated and works on the impact of a teacher on the outcome of students in a class. Heat transfer coefficient and pressure drop with two parameters have been considered to evaluate the performance of the tube. The mass flux and vapour quality of refrigerant are taken as the parameters. The limit of mass flux and vapour quality are from 100 to 300 kg/m2 s and 0.1 to 0.8, respectively. The optimum values of heat transfer coefficient 2820.5 W/m2 K and pressure drop 1360.2 Pa are obtained with mass flux 137.65 kg/m2 s and vapour quality 0.77 using teaching–learning-based optimization algorithm.


Author(s):  
M. Hamayun Maqbool ◽  
Bjo¨rn Palm ◽  
R. Khodabandeh ◽  
Rashid Ali

Experiments have been performed to investigate heat transfer in a circular vertical mini channel made of stainless steel (AISI 316) with internal diameter of 1.70 mm and a uniformly heated length of 245 mm using ammonia as working fluid. The experiments are conducted for a heat flux range of 15 to 350 kW/m2 and mass flux range of 100 to 500 kg/m2s. The effects of heat flux, mass flux and vapour quality on the heat transfer coefficient are explored in detail. The experimental results show that the heat transfer coefficient increases with imposed wall heat flux while mass flux and vapour quality have no considerable effect. Experimental results are compared to predictive methods available in the literature for boiling heat transfer. The correlations of Cooper et al. [1] and Shah [3] are in good agreement with our experimental data.


2017 ◽  
Vol 25 (03) ◽  
pp. 1750027 ◽  
Author(s):  
M. Mostaqur Rahman ◽  
Keishi Kariya ◽  
Akio Miyara

Experiments on condensation heat transfer and adiabatic pressure drop characteristics of R134a were performed inside smooth and microfin horizontal tubes. The tests were conducted in the mass flux range of 50[Formula: see text]kg/m2s to 200[Formula: see text]kg/m2s, vapor quality range of 0 to 1 and saturation temperature range of 20[Formula: see text]C to 35[Formula: see text]C. The effects of mass velocity, vapor quality, saturation temperature, and microfin on the condensation heat transfer and frictional pressure drop were analyzed. It was discovered that the local heat transfer coefficients and frictional pressure drop increases with increasing mass flux and vapor quality and decreasing with increasing saturation temperature. Higher heat transfer coefficient and frictional pressure drop in microfin tube were observed. The present experimental data were compared with the existing well-known condensation heat transfer and frictional pressure drop models available in the open literature. The condensation heat transfer coefficient and frictional pressure drop of R134a in horizontal microfin tube was predicted within an acceptable range by the existing correlation.


Energies ◽  
2021 ◽  
Vol 14 (18) ◽  
pp. 5972
Author(s):  
Yu Xu ◽  
Zihao Yan ◽  
Ling Li

To protect the environment, a new low-GWP refrigerant R1234ze(E) was created to substitute R134a. However, its flow boiling performances have not received sufficient attention so far, which hinders its popularization to some extent. In view of this, an experimental investigation was carried out in a 1.88 mm horizontal circular minichannel. The saturation pressures were maintained at 0.6 and 0.7 MPa, accompanied by mass flux within 540–870 kg/m2 s and heat flux within 25–65 kW/m2. For nucleate boiling, a larger heat flux brings about a larger heat transfer coefficient (HTC), while for convective boiling, the mass flux and vapor quality appear to take the lead role. The threshold vapor quality of different heat transfer mechanisms is around 0.4. Additionally, larger saturation pressure results in large HTC. As for the frictional pressure drop (FPD), it is positively influenced by mass flux and vapor quality, while negatively affected by saturation pressure, and the influence of heat flux is negligible. Furthermore, with the measured data, several existing correlations are compared. The results indicate that the correlations of Saitoh et al. (2007) and Müller-Steinhagen and Heck (1986) perform best on flow boiling HTC and FPD with mean absolute deviations of 5.4% and 10.9%.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6886
Author(s):  
Małgorzata Sikora ◽  
Tadeusz Bohdal ◽  
Karolina Formela

This article presents the results obtained from our own experimental investigations on heat exchange and pressure drop during the condensation flow of the HFE 7000 refrigerant in pipe minichannels with an internal diameter of di = 1.2–2.5 mm. The influence of vapor quality x and the mass flux density G on the two-phase flow pressure drops and heat transfer is presented. The tests were performed for the mass flux density range of G = 110–4700 kg/m2s, saturation inlet temperature of Ts = 36–43 °C and heat flux density of q = 1 ÷ 20 kW/m2. The pressure drop characteristics and heat transfer coefficient as a function of the internal diameter of minichannels are illustrated. The results of experimental research on the heat transfer coefficient and two-phase pressure drop are compared with correlations developed by other authors. The best accuracy has a comparison of experimental study with correlation of Rahman-Kariya-Miyara et al. and Mikielewicz et al.


Author(s):  
Zeguan Dong ◽  
Jianghui Zhang ◽  
Zhen Li ◽  
Yan He ◽  
David J. Kukulka ◽  
...  

Abstract Single-phase and flow condensation experiments were performed using refrigerant R410A in the outer annular region of horizontal enhanced tube with different enhanced surfaces at a saturation temperature of 45°C in the range of mass flux 44.43–102.23kg/(m2s). The vapor quality ranges from 0.8 to 0.2. The outer diameters of the tubes are all 19.05mm, but the inner diameters are slightly different due to different surface structures. The surface structures of the three enhanced tubes are fins(EHT1 tube), toothed structures (EHT2 tube) and fine cavities(EHT3 tube) of different sizes and densities. Among them, the EHT3 tube has internal threads. Wilson diagram method was used to determine the enhancement ratio of the water side heat transfer coefficient of EHT3 tube. It was found that the pressure drop increased with the increase of mass flux, while the heat transfer coefficient showed different trends, and the smooth tube was always the lowest of the four tubes. A comprehensive evaluation factor α combining heat transfer enhancement factor (EF) and pressure drop penalty factor (PF) was defined, in which EHT2 tube (1.38–1.75) was the largest, with strong heat transfer capacity and small pressure drop, so the condensing heat transfer capacity of EHT2 tube was the best.


Author(s):  
Yan Yan ◽  
Jixian Dong ◽  
Tong Ren ◽  
Shiyu Feng

In this study, the condensation heat transfer coefficient and pressure drop of steam are obtained in small rectangular tubes with different aspect ratios. The experiments were carried out on three rectangular tubes with aspect ratios of 1:2, 1:3 and 1:5, with mass flux between 25 and 45 kg/m2s, and vapor qualities between 0.1 and 0.8. The experimental data were analyzed to determine the effect of vapor quality, mass flux, and aspect ratio on the heat transfer coefficient and pressure drop. The results showed that the effect of aspect ratio on condensation heat transfer coefficient appears to be dependent on the flow pattern. For stratified flow, the condensation heat transfer coefficient increases as the mass flux increases. For annular flow, the condensation heat transfer coefficient hardly changed. The pressure drop always increases as the aspect ratio increases. Previous studies on round tube heat transfer and pressure drop correlations have not successfully predicted the small rectangular tube data; therefore, modified Shah correlation and Lockhart & Martinelli correlation are proposed, which predict the data with 20% and 23% RMS error, respectively.


Author(s):  
Luthfi A. F. Haryoko ◽  
Jundika C. Kurnia ◽  
Agus P. Sasmito

Subcooled boiling heat transfer in helically-coiled tubes offers better heat transfer performance than any other types of boiling processes due to its ability to capture high heat flux with a relatively low wall superheat. This study investigates turbulent subcooled forced convection boiling performances of water-vapour in a helically-coiled tube with various operating conditions i.e. operating pressure, heat, and mass flux. Developed CFD model is validated against previously published experimental results using the RPI model. The model is developed based on the Eulerian-Eulerian framework coupled with k-ε RNG turbulence model and Standard Wall-Function. A good agreement is found between numerical prediction and experimental counterpart for the bulk fluid temperature and non-dimensional length. The result indicates that the subcooled boiling heat transfer in a helically-coiled tube tends to improve heat transfer coefficient and pressure drop in the domain. Subcooled boiling starts at the inner side of the helically-coiled tube (f=9900) due to the existence of secondary flow that comes from the coil curvature. Heat transfer coefficient and pressure drop increased with increasing heat flux and decreasing mass flux, and operating pressure. This is caused by the bubble movement and convective heat transfer phenomena in a helically-coiled tube. Finally, this study can provide a guideline for future research of the subcooled boiling in a helically-coiled tube.