scholarly journals Improved harmonic detection method based on ip-iq theory

2021 ◽  
Vol 261 ◽  
pp. 01028
Author(s):  
Zhisen Yao ◽  
Guige Gao

Based on the traditional ip-iq harmonic detection theory, the accuracy of harmonic detection is easily affected by the phase-locked loop (PLL) output phase error, and the single low-pass filter (LPF) detection accuracy and filtering effect cannot be simultaneously. In this paper, an improved harmonic detection method based on the second-order generalized integrator-frequency locked loop (SOGI-FLL) technique is proposed to generate sine and cosine signals with the same frequency as the grid voltage; The traditional low-pass filter and average filter are used in series to improve the response speed and accuracy. Through theoretical analysis of the improved harmonic detection method and simulation in MATLAB environment, the theory and simulation results prove the effectiveness of the improved method.

Author(s):  
Tiezhou Wu ◽  
An Wang ◽  
Yawen Xu

Abstract By using power electronic devices, photovoltaic grid-connected power generation may inject harmonics into the power system. As the photovoltaic grid-connected inverter has the same basic structure as the active power filter, so the unified control of the photovoltaic grid and active filtering can be achieved. When the current unified control system compensates harmonics of the grid side, it mainly uses ip-iq harmonic detection method, which is based on instantaneous reactive power theory. When the three-phase voltage is unbalanced, the method has a large voltage phase angle detection error and the signal of the low-pass filter tracking system is long, detection time delay and even failure occur. This paper proposes an improved fast harmonic detection method. When phase deviation or amplitude change occurs to the three-phase voltage, the positive and negative-sequence voltages are simultaneously park transformed. The negative-sequence component is filtered by the current average module to obtain the fundamental amount of the voltage, then the phase angle of the positive-sequence voltage is accurately calculated to improve the harmonic current detection accuracy. Through the study of the integral method, it is found that the least common multiple of each harmonic period can be used as the integral interval, and the integral value is also zero, so the detection delay time is reduced by replacing the low-pass filter with an integration module. The simulation results show that the proposed harmonic detection algorithm can accurately detect harmonics when the three-phase voltage is unbalanced, and about 0.057 s improve the harmonic detection speed compared with the commonly used ip-iq method.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Jifang Li ◽  
Jidong Wang ◽  
Kunlin Song ◽  
Zhen Feng

By analyzing harmonic related to instantaneous active current and instantaneous reactive current, we propose an improved harmonic detection method to remedy long response delay and low detection accuracy corresponding to harmonic of power system. This method introduces a series connection scheme composed of Low-Pass Filter (LPF) and a current average module firstly. Then, detection accuracy of harmonic current is enhanced by adaptive tuning cut-off frequency of LPF and integration time which was obtained by proposed algorithm of the current average module. Moreover, feedback loop is introduced to compensated delay caused by LPF. Simulations including uncontrollable rectifier and three-phase voltage type inverter show proposed method has many advantages such as high detection accuracy, low response delay and good generality. Our method provides reliable harmonic current detection for later harmonic suppression and harmonic compensation.


2015 ◽  
Vol 22 (3) ◽  
pp. 82-89
Author(s):  
Xiao-Yan Xu ◽  
Janusz Mindykowski ◽  
Tomasz Tarasiuk ◽  
Chen Cheng

Abstract An improved harmonic detection method based on average arithmetic is proposed. According to the research results, the designed solution uses an LPF (low-pass-filter) and a mean value module connected in series instead of the conventional mean value module, and simultaneously, a three-phase voltage phase-locked module instead of commonly used PLL (phase lock loop) module is applied in order to reduce the influence caused by three-phase distorted voltage and rapid variation of load. The experimental results show that the application of this solution leads to increase in the accuracy of harmonics detection for distorted three-phase voltage and rapid variation of load.


2011 ◽  
Vol 130-134 ◽  
pp. 3928-3932
Author(s):  
Ju Xia Ding ◽  
Xiu Feng Zhang ◽  
Hua Jun Zhang

In order to reduce the error of the phase lock-loop (PLL) and compensate the delay of the low pass filter on harmonics detection, In the paper, a detecting-method without PLL in single-phase circuit is researched. In this method, the PLL and LPF are omitted, the feedback and average theory are used, so that the problem of detecting accuracy induced by PLL and real-time induced by LPF is solved. It is testified through comparison, analysis and simulation, that both methods can reduce the latency, improve dynamic response speed, the feedback method can reduce the delay in a dynamic, continuous process, while the average theoretical method can reduce the delay quantitatively.


2012 ◽  
Vol 614-615 ◽  
pp. 907-910
Author(s):  
Xue Song Zhou ◽  
Guang Zhu Chen ◽  
You Jie Ma

This paper describes Detecting Methods for Harmonics of power system has been considered one of the serious harms for power system. The research of harmonics has obtained high attention among people. The researches of harmonics detection have many methods, such as Based on Fryze theory of harmonic power detection, Instantaneous reactive power theory detection method, Fourier Transformation harmonic detection method, wavelet transform detection method, neural networks harmonic detection method etc. Aiming at harmonic detection, the different detection methods of power system harmonics are summarized and compared. This paper reviews the existing harmonic detection methods, and discuss their advantages and disadvantages in terms of detection accuracy and response speed, and finally summarizes the development trend of the harmonic detection method.


2013 ◽  
Vol 860-863 ◽  
pp. 2050-2053
Author(s):  
Xin Yao ◽  
Zai Lin Yao ◽  
Xin Ying Teng

APF harmonic detection is the study of the most important parts of the core , quickly and accurately detect the harmonic current is able to quickly output harmonic compensation circuit current of the premise. Delay compensation system is based on the increase in the method specified time compensation angle , which can accurately detect the harmonic current at the same time , the low-pass filter to minimize the time delay generated by MATLAB simulation, the use of delay compensation system active Filter harmonic Detection and Compensation excellent performance, while ensuring high precision detection and compensation while ensuring at the same time , and fully complete filter real-time functionality .


2015 ◽  
Vol 137 (3) ◽  
Author(s):  
Zamir A. Zulkefli ◽  
Maurice L. Adams

A proposed solution to reducing gear mesh-frequency vibrations in a gear-set involves the utilization of hydrostatic bearings placed in series, load wise, with the main support bearing. The hydrostatic bearings are expected to utilize its low pass filtering effect of the vibrational energies to prevent its transmission from the shaft to the gear housing where it would be emitted as noise. The present investigation examines the frequency response of a single-recess circular hydrostatic bearing under applied sinusoidal loads. The results show that as the driving frequency increases, the filtering effect of the hydrostatic bearing increases. The exhibited behavior is similar to the behavior of a low pass filter: negligible filtering effect at low frequencies, the filtering effect increasing from 0% to 90% over the midfrequencies range and the filtering effect remaining at the maximum value as the frequencies of the applied signals continue to increase. This observed behavior is expected to play a central role in the proposed gear mesh-frequency vibration mitigation system.


2012 ◽  
Vol 614-615 ◽  
pp. 953-956
Author(s):  
Xin Yao ◽  
Zai Lin Yao ◽  
Xin Ying Teng

Harmonic detection is one of the most important core part of Active Power Filter,which can quickly and accurately detect the harmonic current that is the premise of circuit to quickly output harmonic compensation current,therefore the pros and cons of the detection method,a direct impact on the effect of harmonic compensation.Time compensation method is to add a specific time compensation angle based on the method of instantaneous reactive power compensation,so that it can accurately detect the harmonic currents at the same time,minimize the low-pass filter time delay.By MATLAB simulation,the results show high detection accuracy.And to ensure detection and compensation,while fully to improve the real-time function of the filter.


Sign in / Sign up

Export Citation Format

Share Document