scholarly journals The use of hippocampal volumetric measurements to improve diagnostic accuracy in pediatric patients with mesial temporal sclerosis

2017 ◽  
Vol 19 (6) ◽  
pp. 720-728 ◽  
Author(s):  
Gloria J. Guzmán Pérez-Carrillo ◽  
Christopher Owen ◽  
Katherine E. Schwetye ◽  
Spencer McFarlane ◽  
Ananth K. Vellimana ◽  
...  

OBJECTIVEMany patients with medically intractable epilepsy have mesial temporal sclerosis (MTS), which significantly affects their quality of life. The surgical excision of MTS lesions can result in marked improvement or even complete resolution of the epileptic episodes. Reliable radiological diagnosis of MTS is a clinical challenge. The purpose of this study was to evaluate the utility of volumetric mapping of the hippocampi for the identification of MTS in a case-controlled series of pediatric patients who underwent resection for medically refractory epilepsy, using pathology as a gold standard.METHODSA cohort of 57 pediatric patients who underwent resection for medically intractable epilepsy between 2005 and 2015 was evaluated. On pathological investigation, this group included 24 patients with MTS and 33 patients with non-MTS findings. Retrospective quantitative volumetric measurements of the hippocampi were acquired for 37 of these 57 patients. Two neuroradiologists with more than 10 years of experience who were blinded to the patients' MTS status performed the retrospective review of MR images. To produce the volumetric data, MR scans were parcellated and segmented using the FreeSurfer software suite. Hippocampal regions of interest were compared against an age-weighted local regression curve generated with data from the pediatric normal cohort. Standard deviations and percentiles of specific subjects were calculated. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined for the original clinical read and the expert readers. Receiver operating characteristic curves were generated for the methods of classification to compare results from the readers with the authors' results, and an optimal threshold was determined. From that threshold the sensitivity, specificity, PPV, and NPV were calculated for the volumetric analysis.RESULTSWith the use of quantitative volumetry, a sensitivity of 72%, a specificity of 95%, a PPV of 93%, an NPV of 78%, and an area under the curve of 0.84 were obtained using a percentage difference of normalized hippocampal volume. The resulting specificity (95%) and PPV (93%) are superior to the original clinical read and to Reader A and Reader B's findings (range for specificity 74%–86% and for PPV 64%–71%). The sensitivity (72%) and NPV (78%) are comparable to Reader A's findings (73% and 81%, respectively) and are better than those of the original clinical read and of Reader B (sensitivity 45% and 63% and NPV 71% and 70%, respectively).CONCLUSIONSVolumetric measurement of the hippocampi outperforms expert readers in specificity and PPV, and it demonstrates comparable to superior sensitivity and NPV. Volumetric measurements can complement anatomical imaging for the identification of MTS, much like a computer-aided detection tool would. The implementation of this approach in the daily clinical workflow could significantly improve diagnostic accuracy.

2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


2021 ◽  
Vol 10 (1) ◽  
pp. 20-25
Author(s):  
Sujan Shrestha ◽  
Mamen Prasad Gorhaly ◽  
Manil Ratna Bajracharya

Background Diabetic peripheral neuropathy (DPN) is a significant independent risk factor for diabetic foot, and an effective screening instrument is required to diagnose DPN early to prevent future ulceration and amputation. This study aims to determine the diagnostic accuracy of monofilament test to detect diabetic peripheral neuropathy. Methods This cross-sectional study was conducted in National Academy of Medical Sciences, Bir hospital, Mahabouddha, Kathmandu from February 2016 to January 2017. A total of 96 diabetic patients attending inpatient and outpatient Department were selected. Diabetic peripheral neuropathy was assessed by measurement of loss of protective sensation (LOPS) by monofilament test and compared with vibration perception threshold by standard biothesiometer. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were calculated. Results The prevalence of diabetic peripheral neuropathy was 26%. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were found to be 92.0%, 95.8%, 88.5% and 97.1% respectively. There was strong association between LOPS by monofilament and vibration perception threshold by biothesiometer. Conclusion This study showed a strong diagnostic accuracy of monofilament test to detect DPN when compared with biothesiometer. As monofilament test is a cheap, easily available, and portable, it can be used in the periphery where biothesiometer is not available.  


2021 ◽  
pp. 8-13
Author(s):  
Pankaj Kumar Singh ◽  
Budhaditya Sanyal ◽  
Mohit Bhatnagar ◽  
Mandeep Joshi ◽  
Shreya Verma

Aims and objectives: This study aims to assess the diagnostic accuracy and timeliness of ultrasonography by static method only for identication of Endotracheal tube (ET Tube) placement in the trachea in emergency settings vs existing clinical methods. Material and Methods: This prospective study was carried out in the emergency room from October 2018 till the end of March 2019. The ultrasonography was performed in 120 emergency patients only after the intubation had been completed ie, static phase. A linear probe was used over the neck to identify the predened signs of ET intubation. Residents who perform ultrasound examination ll a form after assessment of each patient. Results: It was found that Tracheal Intubation-USG Sensitivity was 99.1, Specicity was 91.7, Positive Predictive Value: 99.1, Negative Predictive Value was 91.7 and Accuracy was 98.3%. Ultrasonography can be used as an adjunct tool to verify the ETTposition by Emergency Physicians which can be performed easily after a brieng or short-course training.Conclusion:This study demonstrates that US imaging has a high diagnostic accuracy to immediately conrm proper ETT placement post-intubation in an emergency setup. Therefore, it seems that ultrasonography using a static technique only is a proper screening tool in determining endotracheal tube placement.


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Tahir Iqbal ◽  
Muhammad Usman Shahid ◽  
Ishfaq Ahmad Shad ◽  
Shahzad Karim Bhatti ◽  
Syed Amir Gilani ◽  
...  

ABSTRACT: BACKGROUND: A common surgical emergency is acute appendicitis. Various diagnostic tools are available to diagnosis acute appendicitis. Radiological investigations play an important role in making accurate and early diagnosis and thus preventing morbidity associated with the disease. OBJECTIVE: To determine the diagnostic accuracy of gray scale ultrasonography versus color Doppler in suspected cases of acute appendicitis. MATERIALS AND METHODS: The study was carried in the department of Radiology of Mayo Hospital, Lahore. A total of 75 patients were enrolled of age 18-40 years, both genders who were suspected cases of acute appendicitis. All patients underwent baseline investigations along with gray scale ultrasonography and color Doppler. All patients were subjected to surgery to confirm the diagnosis and findings were subjected to statistical analysis. RESULTS: The mean age of the patients was 23.25 ±10.55 and mean transverse diameter of appendix was 8.37 ±3.39. There were 62.7% males and 37.3%females. Findings of gray scale ultrasonography and color Doppler were then correlated with surgical findings to calculate the diagnostic accuracy of these modalities. The results revealed that gray scale ultrasonography sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 92.7%, 94.32%, 95%, 91.4% and 93.3% respectively, whereas color Doppler had sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 97.7%, 93.9%, 95.3%, 97% and 96% respectively. Diagnostic accuracy of both modalities together was 98.6%. CONCLUSION: Color Doppler has better diagnostic accuracy than gray scale ultrasonography for diagnosis of acute appendicitis and the combination of both modalities yields diagnostic accuracy that is similar to gold standard.


2012 ◽  
Vol 20 (01) ◽  
pp. 132-138
Author(s):  
MUHAMMAD ATIF ◽  
MUHAMMAD ABDULLAH ◽  
MUHAMMAD JAVAD YOUSAF ◽  
Khalid Buland

Objective: To compare the accuracy of Upper lip bite test with modified Mallampati classification for predicting the difficultlaryngoscopic intubation. Study Design: Cross sectional Study. Place and duration of study: The study was carried out at Department ofAnaesthesiology, Intensive Care and Pain management, Combined Military hospital, Rawalpindi from September 2008 to August 2009.Patients and Methods: Four hundred patients undergoing elective surgery meeting the inclusion/exclusion criteria were enrolled afterwritten informed consent. The airways of the patients were evaluated by using the modified Mallampati classification (MMP) and theUpper lip bite test (ULBT). MMP class 3 or 4 and ULBT class 3 were considered as indicators of difficult intubation. The laryngeal view wasgraded by Cormack and Lehane classification (Gold standard). Grade 1 or 2 was considered to represent easy intubation and grade 3 or 4to represent difficult intubation. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy werecalculated for both the tests separately by using the 2×2 table. Results: ULBT had a higher accuracy of 94%, specificity of 99.2% andpositive predictive value 70% compared to MMP accuracy of 82.7%, specificity of 84.4% and positive predictive value of 22.7%.Conclusions: The diagnostic accuracy of the Upper lip bite test was more than the modified Mallampati classification. We suggest that itbe compared with the other prevailing tests as well which are often used to assess difficult intubations.


2021 ◽  
pp. 036354652110271
Author(s):  
Michael G. Saper ◽  
Viviana Bompadre ◽  
Gregory A. Schmale ◽  
Sarah Menashe ◽  
Monique Burton ◽  
...  

Background: An anteroposterior (AP) radiograph of the elbow in 45° of flexion has been suggested to increase the diagnostic accuracy of capitellum osteochondritis dissecans (OCD). Purpose: To assess the diagnostic performance, inter- and intraobserver reliability, and confidence level for identifying capitellum OCD using plain radiographs (AP, lateral, and 45° flexion AP). Study Design: Cohort study (Diagnosis); Level of evidence, 3. Methods: This was a retrospective study of pediatric and adolescent patients with capitellum OCD and a control group. Six independent clinicians who were blinded to the official radiologists’ reports reviewed images on 2 separate occasions, 1 week apart. A 5-point Likert scale was used to assess the clinicians’ level of confidence. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for individual and combinations of radiographic views. Inter- and intraobserver reliability was determined using Cohen kappa (κ) coefficients. Results: A total of 28 elbows (mean age, 12.5 ± 2 years) were included. There were no differences in age ( P = .18), sex ( P = .62), or laterality ( P > .999) between groups. There were marked variations in the diagnostic accuracy between views: sensitivity (AP, 85.1; lateral, 73.2; 45° flexion AP, 91.7), specificity (AP, 89.3; lateral, 91.7; 45° flexion AP, 91.1), PPV (AP, 88.8; lateral, 89.8; 45° flexion AP, 91.1), NPV (AP, 85.7; lateral, 77.4; 45° flexion AP, 91.6), and accuracy (AP, 87.2; lateral, 82.4; 45° flexion AP, 91.4). Standard radiographs (AP and lateral views) failed to diagnose capitellum OCD in 4.8% of cases. The sensitivity of the 3 combined views was 100%. Confidence intervals in the clinicians’ diagnostic assessments were similar for each view (AP, 4.0; lateral, 4.0; and 45° flexion AP, 4.1). Interobserver reliability was substantial for AP and lateral views (κ = 0.65 and κ = 0.60, respectively) but highest for the 45° flexion AP radiographs (κ = 0.72). Intraobserver reliability for the 45° flexion AP view was moderate to almost perfect (κ = 0.45 to 0.93). Conclusion: The 45° flexion AP view can detect capitellum OCD with excellent accuracy, a high level of confidence, and substantial interobserver agreement. When added to standard AP and lateral radiographs, the 45° flexion AP view aids in the identification of capitellum OCD.


Endoscopy ◽  
2019 ◽  
Vol 52 (02) ◽  
pp. 107-114 ◽  
Author(s):  
Adriaan B. de Vries ◽  
Frans van der Heide ◽  
Rinze W. F. ter Steege ◽  
Jan Jacob Koornstra ◽  
Karel T. Buddingh ◽  
...  

Abstract Background Single-operator peroral cholangioscopy (sPOCS) is considered a valuable diagnostic modality for indeterminate biliary strictures. Nevertheless, studies show large variation in its characteristics and measures of diagnostic accuracy. Our aim was to estimate the diagnostic accuracy of sPOCS visual assessment and targeted biopsies for indeterminate biliary strictures. Additional aims were: estimation of the clinical impact of sPOCS and comparison of diagnostic accuracy with brush cytology. Methods A retrospective single-center study of adult patients who underwent sPOCS for indeterminate biliary strictures was performed. Diagnostic accuracy was defined as sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The clinical impact of sPOCS was assessed by review of medical records, and classified according to its influence on patient management. Results 80 patients were included, with 40 % having primary sclerosing cholangitis (PSC). Prior ERCP was performed in 88 %, with removal of a biliary stent prior to sPOCS in 55 %. The sensitivity, specificity, PPV, and NPV for sPOCS visual impression and targeted biopsies were 64 %, 62 %, 41 %, and 84 %, and 15 %, 65 %, 75 %, and 69 %, respectively. The clinical impact of sPOCS was limited; outcome changed management in 17 % of patients. Sequential brush cytology sensitivity, specificity, PPV, and NPV were 47 %, 95 %, 80 %, and 83 %. Conclusions The diagnostic accuracy of sPOCS for indeterminate biliary strictures was found to be inferior to brush cytology, with a low impact on patient management. These findings are obtained from a select patient population with a high prevalence of PSC and plastic stents in situ prior to sPOCS.


2018 ◽  
Vol 10 (3) ◽  
Author(s):  
Pokpong Piriyakhuntorn ◽  
Adisak Tantiworawit ◽  
Thanawat Rattanathammethee ◽  
Chatree Chai-Adisaksopha ◽  
Ekarat Rattarittamrong ◽  
...  

This study aims to find the cut-off value and diagnostic accuracy of the use of RDW as initial investigation in enabling the differentiation between IDA and NTDT patients. Patients with microcytic anemia were enrolled in the training set and used to plot a receiving operating characteristics (ROC) curve to obtain the cut-off value of RDW. A second set of patients were included in the validation set and used to analyze the diagnostic accuracy. We recruited 94 IDA and 64 NTDT patients into the training set. The area under the curve of the ROC in the training set was 0.803. The best cut-off value of RDW in the diagnosis of NTDT was 21.0% with a sensitivity and specificity of 81.3% and 55.3% respectively. In the validation set, there were 34 IDA and 58 NTDT patients using the cut-off value of >21.0% to validate. The sensitivity, specificity, positive predictive value and negative predictive value were 84.5%, 70.6%, 83.1% and 72.7% respectively. We can therefore conclude that RDW >21.0% is useful in differentiating between IDA and NTDT patients with high diagnostic accuracy


2014 ◽  
Vol 35 (06) ◽  
pp. 685-691 ◽  
Author(s):  
H. L. Wald ◽  
B. Bandle ◽  
A. Richard ◽  
S. Min

Objective.To develop and validate a methodology for electronic surveillance of catheter-associated urinary tract infections (CAUTIs).Design.Diagnostic accuracy study.Setting.A 425-bed university hospital.Subjects.A total of 1,695 unique inpatient encounters from November 2009 through November 2010 with a high clinical suspicion of CAUTI.Methods.An algorithm was developed to identify incident CAUTIs from electronic health records (EHRs) on the basis of the Centers for Disease Control and Prevention (CDC) surveillance definition. CAUTIs identified by electronic surveillance were compared with the reference standard of manual surveillance by infection preventionists. To determine diagnostic accuracy, we created 2 × 2 tables, one unadjusted and one adjusted for misclassification using chart review and case adjudication. Unadjusted and adjusted test statistics (percent agreement, sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV], and κ) were calculated.Results.Electronic surveillance identified 64 CAUTIs compared with manual surveillance, which identified 19 CAUTIs for 97% agreement, 79% sensitivity, 97% sensitivity, 23% PPV, 100% NPV, and κ of .33. Compared with the reference standard adjusted for misclassification, which identified 55 CAUTIs, electronic surveillance had 98% agreement, 80% sensitivity, 99% specificity, 69% PPV, 99% NPV, and κ of .71.Conclusion.The electronic surveillance methodology had a high NPV and a low PPV compared with the reference standard, indicating a role of the electronic algorithm in screening data sets to exclude cases. However, the PPV markedly improved compared with the reference standard adjusted for misclassification, suggesting a future role in surveillance with improvements in EHRs.Infect Control Hosp Epidemiol2014;35(6):685–691


2019 ◽  
Vol 13 (2) ◽  
pp. 22-24
Author(s):  
Zebun Nahar ◽  
Md Enamul Kabir ◽  
Taharul Alam ◽  
Shamoli Yasmin ◽  
Maisha Naowar

Introduction: Breast cancer is the most common cancer and second leading cause of cancer deaths in women. Early detection, efficient and accurate diagnosis can reduce the mortality rate. Objectives: To compare the screening accuracy of mammography (MMG) and ultrasonography (USG) in suspected cases of breast masses. Material and Methods: This cross-sectional analytical study was carried out in the Department of Radiology and Imaging, Combined Military Hospital, Dhaka from June 2016 to July 2017. A total of 100 clinically suspected case of breast masses aged from 20 to 75 years referred for MMG and USG was selected. Each patient underwent USG and MMG followed by a histopathological examination of the biopsy material taken from the lump lesion. Two cases histopathological report was not found. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy of USG and MMG were compared with histopathology as the gold standard. In order to determine the agreement of diagnoses between USG and MMG, consistency analysis was performed using Kappa-statistics. Results: Sensitivity, specificity, PPV, NPV and diagnostic accuracy of USG was 58.8%, 98.4%, 77.8%, 85.0% and 83.6% and for MMG 92.0%, 84.5%, 67.6%, 96.8% and 84.7% respectively. Kappa-statistics shows that the two diagnostic modalities had a test agreement in 39.8% cases to differentiate malignant breast tumour from the benign one (k-value = 0.398, p > 0.05). Conclusion: Two diagnostic modalities USG and MMG had a fair agreement in the differentiation of malignant breast tumour from the benign. Journal of Armed Forces Medical College Bangladesh Vol.13(2) 2017: 22-24


Sign in / Sign up

Export Citation Format

Share Document