scholarly journals Speech Perception Benefit for Children with a Cochlear Implant and a Hearing Aid in Opposite Ears and Children with Bilateral Cochlear Implants

2010 ◽  
Vol 15 (1) ◽  
pp. 44-56 ◽  
Author(s):  
Mansze Mok ◽  
Karyn L. Galvin ◽  
Richard C. Dowell ◽  
Colette M. McKay
2016 ◽  
Vol 21 (03) ◽  
pp. 206-212 ◽  
Author(s):  
Grace Ciscare ◽  
Erika Mantello ◽  
Carla Fortunato-Queiroz ◽  
Miguel Hyppolito ◽  
Ana Reis

Introduction A cochlear implant in adolescent patients with pre-lingual deafness is still a debatable issue. Objective The objective of this study is to analyze and compare the development of auditory speech perception in children with pre-lingual auditory impairment submitted to cochlear implant, in different age groups in the first year after implantation. Method This is a retrospective study, documentary research, in which we analyzed 78 reports of children with severe bilateral sensorineural hearing loss, unilateral cochlear implant users of both sexes. They were divided into three groups: G1, 22 infants aged less than 42 months; G2, 28 infants aged between 43 to 83 months; and G3, 28 older than 84 months. We collected medical record data to characterize the patients, auditory thresholds with cochlear implants, assessment of speech perception, and auditory skills. Results There was no statistical difference in the association of the results among groups G1, G2, and G3 with sex, caregiver education level, city of residence, and speech perception level. There was a moderate correlation between age and hearing aid use time, age and cochlear implants use time. There was a strong correlation between age and the age cochlear implants was performed, hearing aid use time and age CI was performed. Conclusion There was no statistical difference in the speech perception in relation to the patient's age when cochlear implant was performed. There were statistically significant differences for the variables of auditory deprivation time between G3 - G1 and G2 - G1 and hearing aid use time between G3 - G2 and G3 - G1.


2010 ◽  
Vol 21 (01) ◽  
pp. 052-065 ◽  
Author(s):  
Richard S. Tyler ◽  
Shelley A. Witt ◽  
Camille C. Dunn ◽  
Ann Perreau ◽  
Aaron J. Parkinson ◽  
...  

Objectives: The purpose of this investigation was to determine if adult bilateral cochlear implant recipients could benefit from using a speech processing strategy in which the input spectrum was interleaved among electrodes across the two implants. Design: Two separate experiments were conducted. In both experiments, subjects were tested using a control speech processing strategy and a strategy in which the full input spectrum was filtered so that only the output of half of the filters was audible to one implant, while the output of the alternative filters was audible to the other implant. The filters were interleaved in a way that created alternate frequency “holes” between the two cochlear implants. Results: In experiment one, four subjects were tested on consonant recognition. Results indicated that one of the four subjects performed better with the interleaved strategy, one subject received a binaural advantage with the interleaved strategy that they did not receive with the control strategy, and two subjects showed no decrement in performance when using the interleaved strategy. In the second experiment, 11 subjects were tested on word recognition, sentences in noise, and localization (it should be noted that not all subjects participated in all tests). Results showed that for speech perception testing one subject achieved significantly better scores with the interleaved strategy on all tests, and seven subjects showed a significant improvement with the interleaved strategy on at least one test. Only one subject showed a decrement in performance on all speech perception tests with the interleaved strategy. Out of nine subjects, one subject preferred the sound quality of the interleaved strategy. No one performed better on localization with the interleaved strategy. Conclusion: Data from this study indicate that some adult bilateral cochlear implant recipients can benefit from using a speech processing strategy in which the input spectrum is interleaved among electrodes across the two implants. It is possible that the subjects in this study who showed a significant improvement with the interleaved strategy did so because of less channel interaction; however, this hypothesis was not directly tested.


2010 ◽  
Vol 20 (2) ◽  
pp. 70-75 ◽  
Author(s):  
Lisa S. Davidson

Cochlear implant (CI) candidacy guidelines continue to evolve as a result of advances in both cochlear implant and hearing aid technology. Empirical studies comparing the speech perception abilities of children using cochlear implants or hearing aids will be reviewed in the context of current device technology and CI candidacy evaluations.


2015 ◽  
Vol 24 (4) ◽  
pp. 462-468 ◽  
Author(s):  
Jessica J. Messersmith ◽  
Lindsey E. Jorgensen ◽  
Jessica A. Hagg

Purpose The purpose of this study was to determine whether an alternate fitting strategy, specifically adjustment to gains in a hearing aid (HA), would improve performance in patients who experienced poorer performance in the bimodal condition when the HA was fit to traditional targets. Method This study was a retrospective chart review from a local clinic population seen during a 6-month period. Participants included 6 users of bimodal stimulation. Two performed poorer in the cochlear implant (CI) + HA condition than in the CI-only condition. One individual performed higher in the bimodal condition, but the overall performance was low. Three age range–matched users whose performance increased when the HA was used in conjunction with a CI were also included. The HA gain was reduced beyond 2000 Hz. Speech perception scores were obtained pre- and postmodification to the HA fitting. Results All listeners whose HA was programmed using the modified approach demonstrated improved speech perception scores with the modified HA fit in the bimodal condition when compared with the traditional HA fit in the bimodal condition. Conclusion Modifications to gains above 2000 Hz in the HA may improve performance for bimodal listeners who perform more poorly in the bimodal condition when the HA is fit to traditional targets.


2021 ◽  
pp. 189-191

BACKGROUND: High-frequency spinal cord stimulation (HF-SCS) has become very popular in the management of chronic pain worldwide. As it relies on generating high-frequency electrical impulses, there is a risk of interference with other devices such as cochlear implants that utilize similar principles. A literature search did not reveal any case reports of HF-SCS implantation in a patient with cochlear implants. CASE REPORT: A 75-year-old White woman with a history of bilateral cochlear implants (Cochlear Americas Nucleus® with cp910 processor) for severe sensorineural hearing loss presented to our chronic pain clinic with lumbosacral radiculopathy. The patient underwent a HF-SCS trial with entry point at the L1-L2 space and the leads positioned at the top and bottom of T8. The patient did not experience any auditory interference with her Cochlear implant at triple the average SCS stimulation strength. During the follow-up visit the next week, the patient reported nearly 80% symptomatic pain relief and significant functional improvement. There was no change in her hearing and no evidence of interference. The patient ultimately underwent percutaneous SCS paddle electrode placement and at 3 months, continues to have excellent pain relief without any auditory interactions. CONCLUSION: We successfully implanted a HF-SCS at the thoracic level in a patient with bilateral cochlear implants without any auditory interference. KEY WORDS: Cochlear implant, lumbar radiculopathy, spinal cord stimulation


2011 ◽  
Vol 32 (01) ◽  
pp. 073-089 ◽  
Author(s):  
Michael Dorman ◽  
William Yost ◽  
Blake Wilson ◽  
Rene Gifford

2019 ◽  
Vol 23 (03) ◽  
pp. e292-e298
Author(s):  
Natalia Martinez Fernandes ◽  
Daniela Gil ◽  
Marisa Frasson de Azevedo

Introduction The mismatch negativity (MMN) is a negative long-latency auditory potential elicited by any discriminable change in a repetitive aspect of auditory stimulation. This evoked potential can provide cortical information about the sound processing, including in children who use cochlear implants. Objective To identify MMN characteristics regarding latency, amplitude, and wave area in cochlear implanted children and to identify associations among language development, speech perception and family involvement. Methods This is a descriptive, observational, cross-sectional study, which compared two groups: study group—children with cochlear implant, and control group—hearing children. The children were submitted to MMN evaluation with non-verbal tone burst stimulus, differing in frequency in sound field at 70 dBHL, with SmartEP equipment (Intelligent Hearing Systems, Miami, FL, USA). Speech perception and language development questionnaires were also applied, and the family participation in the rehabilitation process was classified. Results The occurrence of MMN was 73.3% for the control group and 53.3% for the study group. Values of latency, amplitude and area of MMN of children using cochlear implants were similar to those of hearing children, and did not differ between groups. The occurrence of MMN was not correlated to the variables of hearing, language and family categories. Conclusion Children with cochlear implants showed similar MMN responses to those of the children in the control group, with mean latency, amplitude and area of 208.9 ms (±12.8), -2.37 μV (±0.38) and 86.5 μVms (±23.4), respectively. There was no correlation between the presence of MMN and children's performance in the auditory and language development tests or family involvement during rehabilitation.


2007 ◽  
Author(s):  
James D. Miller ◽  
Charles S. Watson ◽  
Doris J. Kistler ◽  
Frederic L. Wightman ◽  
Jill E. Preminger

1990 ◽  
Vol 33 (2) ◽  
pp. 229-237 ◽  
Author(s):  
Arlene Earley Carney ◽  
Marjorie Kienle ◽  
Richard T. Miyamoto

Suprasegmental and segmental speech perception tasks were administered to 8 patients with single-channel cochlear implants. Suprasegmental tasks included the recognition of syllable number, syllabic stress, and intonation. Segmental tasks included the recognition of vowels and consonants in three modalities: visual only, implant only, and visual + implant. Results were compared to those obtained from artificially deafened adults using a single-channel vibrotactile device (Carney, 1988; Carney & Beachler, 1986). The patterns of responses for both suprasegmental and segmental tasks were highly similar for both groups of subjects, despite differences between the characteristics of the subject samples. These results suggest that single-channel sensory devices, whether they be cochlear implants or vibrotactile aids, produce similar patterns of speech perception errors, even when differences are observed in overall performance level.


Sign in / Sign up

Export Citation Format

Share Document