SENSITIVE AND SPECIFIC ENZYME-LINKED IMMUNOSORBENT ASSAY FOR UROKINASE-TYPE PLASMINOGEN ACTIVATOR IN HUMAN PLASMA

Author(s):  
J Grøndahl-HANSEN ◽  
N Agerlin ◽  
L S Nielsen ◽  
K Danø

An enzyme-linked immunosorbent assay (ELISA) was developed for the measurement of human urokinase-type plasminogen activator (u-PA) in plasma and serum. Microtiter plates were coated with a monoclonal antibody and incubated with standard or sample. Bound u-PA was quantitated with polyclonal antibodies conjugated with biotin, followed by avidin-peroxidase. The assay was 10-fold as sensitive as other previously reported ELISAs, the detection limit being approximately 1 pg of u-PA in a volume of 100 μl with a linear dose-response up to 15 pg of u-PA. The assay detected active u-PA and its inactive proenzyme form equally well and the recovery of both forms was higher than 90% in plasma. A variety of structurally related proteins, including t-PA, were tested, but no reaction with proteins other than u-PA and its amino-terminal degradation product were observed. The intra-assay and inter-assay coefficients of variation for determination of u-PA in plasma were 7.6% and 8.4%, respectively. The assay was equally applicable to serum. The values obtained with plasma and serum were similar, and the results were not affected by small variations in the preparation of the samples. The ELISA was used to measure the concentration of u-PA in plasma from 34 healthy donors. The mean values for u-PA in plasma from healthy donors was 1.1 ng/ml ± 0.3 ng/ml (SD) (range 0.6 - 1.5 ng/ml). No significant differences were found between men and women and no correlation between u-PA concentration and age could be demonstrated.The mean u-PA concentration in plasma from healthy donors obtained in this study is substantially lower than that reported by others. This might be due to different methods of determination of the protein content of the standard preparations or to differences in the specificity of the assays.

Blood ◽  
1996 ◽  
Vol 87 (7) ◽  
pp. 2775-2781 ◽  
Author(s):  
Y Jiang ◽  
R Pannell ◽  
JN Liu ◽  
V Gurewich

Endogenous urokinase-type plasminogen activator (u-PA) has been identified in platelet membrane, and platelets have been shown to take up exogenous high molecular weight u-PA from the ambient medium. In this report, the mechanism of the association of u-PA with platelets was investigated using recombinant, single chain u-PA. When gel filtered human platelets were incubated with radiolabeled u-PA, the u- PA was found to specifically and saturably bind to the resting platelets in a dose-dependent manner. Unlabeled u-PA and the amino terminal fragment of u-PA inhibited 125I-u-PA binding to platelets with a mean IC50 of 65 and 58 nmol/L, respectively. A single saturable binding site in intact resting platelets was found with a mean kd of 43 +/- 25 nmol/L and 2263 +/- 809 sites per platelet. In contrast to resting platelets, 125I-u-PA did not bind to thrombin-induced platelets. Western blotting studies, using a monoclonal or a polyclonal antibody specific for the u-PA cell-surface receptor (u- PAR), failed to show evidence of u-PAR in resting platelets, whereas, u-PAR was found at approximately 54 and approximately 48 kD on U937 monocytes, which served as a positive control. Ligand blotting of platelet membrane and of U937 cell proteins with 125I-u-PA revealed a u-PA binding protein of approximately 70 kD in the platelets and one of approximately 54 kD in the U937 cells. Complexion of u-PA with a platelet membrane protein was also shown by gel filtration of a mixture of u-PA and platelet membrane proteins. A u-PA complex was further shown by enzyme-linked immunosorbent assay when microtiter plates were coated with platelet membrane proteins, and this complex formation was shown to be dose-dependent and saturable with an apparent kd of 17 nmol/L. It was concluded that platelet membrane contains a specific, high affinity u-PA-binding protein that is distinct from u-PAR.


1986 ◽  
Vol 56 (03) ◽  
pp. 411-414 ◽  
Author(s):  
V Darras ◽  
M Thienpont ◽  
D C Stump ◽  
D Collen

SummaryAn enzyme-linked immunosorbent assay (ELISA) for the measurement of urokinase-type plasminogen activator (u-PA) was developed. Three murine monoclonal antibodies to single chain urokinase-type plasminogen activator (scu-PA) were isolated and shown to react with non-overlapping epitopes in scu-PA. Two of the three antibodies were coated onto microtiter plates and bound u-PA was quantitated with the third antibody conjugated to horseradish peroxidase. The assay was equally sensitive to Mr 54,000 u-PA in the single chain or two-chain form but did not respond to Mr 33,000 urokinase. The lower limit of sensitivity of the assay was 0.1 ng/ml in buffer and 1 ng/ml in plasma. Coefficients of variation of the assay at physiological levels of u-PA were 6.5 percent within assays and 13 percent between assays. The level of u-PA in normal resting plasma was 1.9 ± 0.66 ng/ml (mean ± SD, n = 54). The assay can be performed within one working day and provides an efficient, reproducible, and stable means for the measurement of u-PA in biological fluids. As such it may facilitate physiological and pharmacological studies of urokinase-type plasminogen activators in man.


1992 ◽  
Vol 67 (01) ◽  
pp. 095-100 ◽  
Author(s):  
Paul J Declerck ◽  
Leen Van Keer ◽  
Maria Verstreken ◽  
Désiré Collen

SummaryAn enzyme-linked immunosorbent assay (ELISA) for quantitation of natural and recombinant plasminogen activators containing the serine protease domain (B-chain) of urokinase-type plasminogen activator (u-PA) was developed, based on two murine monoclonal antibodies, MA-4D1E8 and MA-2L3, raised against u-PA and reacting with non-overlapping epitopes in the B-chain. MA-4D1E8 was coated on microtiter plates and bound antigen was quantitated with MA-2L3 conjugated with horseradish peroxidase. The intra-assay, inter-assay and inter-dilution coefficients of variation of the assay were 6%, 15% and 9%, respectively. Using recombinant single-chain u-PA (rscu-PA) as a standard, the u-PA-related antigen level in normal human plasma was 1.4 ± 0.6 ng/ml (mean ± SD, n = 27).The ELISA recognized the following compounds with comparable sensitivity: intact scu-PA (amino acids, AA, 1 to 411), scu-PA-32k (AA 144 to 411), a truncated (thrombin-derived) scu-PA comprising A A 157 to 411, and chimeric t-PA/u-PA molecules including t-PA(AA1-263)/scu-PA(AA144-411), t-PA(AA1-274)/scu-PA(AA138-411) and t-PA(AA87-274)/scu-PA(AA138-411). Conversion of single-chain to two-chain forms of u-PA or inhibition of active two-chain forms with plasminogen activator inhibitor-1 or with the active site serine inhibitor phenyl-methyl-sulfonyl fluoride, did not alter the reactivity in the assay. In contrast, inactivation with α2-antiplasmin or with the active site histidine inhibitor Glu-Gly-Arg-CH2Cl resulted in a 3- to 5-fold reduction of the reactivity. When purified scu-PA-32k was added to pooled normal human plasma at final concentrations ranging from 20 to 1,000 ng/ml, recoveries in the ELISA were between 84 and 110%.The assay was successfully applied for the quantitation of pharmacological levels of scu-PA and t-PA(AA87_274)/scu-PA(AA138-411) in plasma during experimental thrombolysis in baboons.Thus the present ELISA, which is specifically dependent on the presence of the serine protease part of u-PA, is useful for measurement of a wide variety of variants and chimeras of u-PA which are presently being developed for improved thrombolytic therapy.


1983 ◽  
Vol 50 (03) ◽  
pp. 740-744 ◽  
Author(s):  
Nils Bergsdorf ◽  
Torbjörn Nilsson ◽  
Per Wallén

SummaryUtilizing the immunoglobulin fraction from a goat antiserum against human uterine tissue plasminogen activator, an enzyme- linked immunoassay for tissue-type plasminogen activator in human plasma has been developed. With the new method, the concentration of t-PA in normal human acidified plasma is found to be 4.0 ± 1.8 (SD) ng/ml. It increases to 12 ng/ml after a tomiquet test, and to 14 ng/ml after strenous physical exercise. In a group of patients with idiopathic thromboembolic disease, the resting t-PA concentration was 5 ng/ml and the post-occlusion value 16 ng/ml. Furthermore, the patients also exhibited a normal post-occlusion rise in the concentration of plasmin-α2-antiplasmin complex. However, in 37% of the post-occlusion patient plasmas, virtually no increase in t-PA could be detected by a specific activity assay. The results indicate that the reason for a defective post-occlusion fibrinolytic activity in a majority of cases may be the presence of increased concentrations of a fast-acting specific t-PA inhibitor.


Blood ◽  
1990 ◽  
Vol 75 (9) ◽  
pp. 1794-1800 ◽  
Author(s):  
PJ Declerck ◽  
HR Lijnen ◽  
M Verstreken ◽  
H Moreau ◽  
D Collen

Abstract A murine monoclonal antibody (MA-12E6A8) was raised against human urokinase-type plasminogen activator (u-PA), which, in an enzyme-linked immunosorbent assay (ELISA), reacted 15,000-fold better with recombinant two-chain u-PA (rtcu-PA) than with recombinant single-chain u-PA (rscu-PA). The antibody had no effect on the activity of rtcu-PA or on its inhibition by a chloromethylketone, but reduced the inhibition of rtcu-PA by recombinant plasminogen activator inhibitor-1 (rPAI-1) at least 10-fold. The dissociation constant of the rtcu-PA/MA- 12E6A8 complex was 7 nmol/L. An ELISA was developed using MA-12E6A8 as capture antibody and a horseradish peroxidase conjugated u-PA specific antibody for tagging. It recognized free and active site blocked rtcu- PA but not rtcu-PA in complex with rPAI-1 or with alpha 2-antiplasmin. This ELISA was used to monitor the generation of rtcu-PA during fibrin clot lysis with rscu-PA in human plasma. Addition of 5 micrograms/mL rscu-PA to 3 mL plasma containing a 0.2 mL 125I-fibrin labeled plasma clot caused 50% clot lysis in 62 +/- 13 minutes (mean +/- SD, n = 6), at which time 99 +/- 28 ng/mL rtcu-PA was detected but no fibrinogen breakdown had occurred. Fifty percent fibrinogen breakdown did occur only when rtcu-PA had reached a level of 1,000 +/- 270 ng/mL (at 150 +/- 21 minutes). rscu-PA, 2 micrograms/mL, induced 50% clot lysis in 160 +/- 41 minutes (n = 6); no fibrinogen degradation occurred within 4 hours and rtcu-PA levels did not exceed 80 ng/mL. In the absence of a fibrin clot, 5 micrograms/mL rscu-PA added to human plasma did not result in significant generation of rtcu-PA (less than 50 ng/mL after 4 hours) and no fibrinogen degradation was observed. These results indicate that clot lysis with rscu-PA in a plasma milieu does not require extensive systemic conversion of rscu-PA to rtcu-PA, and that fibrinogen degradation occurs secondarily to systemic conversion of rscu-PA to rtcu-PA.


Author(s):  
Ping-Kun Tsai ◽  
Shih-Ming Tsao ◽  
Wei-En Yang ◽  
Chao-Bin Yeh ◽  
Hsiang-Ling Wang ◽  
...  

The urokinase-type plasminogen activator receptor (uPAR) mediates various cellular activities and is involved in proteolysis, angiogenesis, and inflammation. The objective of this study was to investigate the association between soluble uPAR (suPAR) levels and community-acquired pneumonia (CAP) severity. A commercial enzyme-linked immunosorbent assay (ELISA) was performed to measure the plasma suPAR levels in 67 healthy controls and 75 patients with CAP. Our results revealed that plasma suPAR levels were significantly elevated in patients with CAP compared with the controls, and antibiotic treatment was effective in reducing suPAR levels. The plasma suPAR levels were correlated with the severity of CAP based on the pneumonia severity index (PSI) scores. Furthermore, lipopolysaccharide (LPS)-stimulation significantly increased uPAR expression in RAW 264.7 macrophages. In conclusion, plasma suPAR levels may play a role in the clinical assessment of CAP severity; these findings may provide information on new targets for treatment of CAP.