Effect of Oligohydramnios on Fetal Heart Rate Patterns during Term Labor Induction

2018 ◽  
Vol 36 (07) ◽  
pp. 715-722
Author(s):  
Janine S. Rhoades ◽  
Molly J. Stout ◽  
George A. Macones ◽  
Alison G. Cahill

Objective To estimate the effect of oligohydramnios on fetal heart rate (FHR) patterns in patients undergoing induction of labor (IOL) at term. Study Design Secondary analysis of a prospective cohort study of consecutive term, singleton deliveries from 2010 to 2015. We included all patients who underwent IOL. Our primary outcomes were electronic fetal monitoring (EFM) characteristics in the 2 hours preceding delivery. Outcomes were compared between those induced with oligohydramnios and those induced without a diagnosis of oligohydramnios. Our secondary outcome was composite neonatal morbidity. Logistic regression was used to control for confounders. Results Of 3,787 patients who underwent IOL, 147 had a diagnosis of oligohydramnios and 3,640 were included in the no oligohydramnios group. There was no significant difference in EFM characteristics between the two groups. There was no difference in composite neonatal morbidity. In patients with oligohydramnios, EFM patterns with baseline tachycardia for 30 minutes or greater were significantly associated with composite neonatal morbidity (31.3 vs. 5.3% adjusted odds ratio 8.63, 95% confidence interval 2.18, 34.1]). Conclusion Term patients undergoing IOL with oligohydramnios had EFM patterns that did not differ from their induced peers.

2011 ◽  
Vol 2011 ◽  
pp. 1-7 ◽  
Author(s):  
Karolina Afors ◽  
Edwin Chandraharan

The aim of intrapartum continuous electronic fetal monitoring using a cardiotocograph (CTG) is to identify a fetus exposed to intrapartum hypoxic insults so that timely and appropriate action could be instituted to improve perinatal outcome. Features observed on a CTG trace reflect the functioning of somatic and autonomic nervous systems and the fetal response to hypoxic or mechanical insults during labour. Although, National Guidelines on electronic fetal monitoring exist for term fetuses, there is paucity of recommendations based on scientific evidence for monitoring preterm fetuses during labour. Lack of evidence-based recommendations may pose a clinical dilemma as preterm births account for nearly 8% (1 in 13) live births in England and Wales. 93% of these preterm births occur after 28 weeks, 6% between 22–27 weeks, and 1% before 22 weeks. Physiological control of fetal heart rate and the resultant features observed on the CTG trace differs in the preterm fetus as compared to a fetus at term making interpretation difficult. This review describes the features of normal fetal heart rate patterns at different gestations and the physiological responses of a preterm fetus compared to a fetus at term. We have proposed an algorithm “ACUTE” to aid management.


2017 ◽  
Vol 34 (09) ◽  
pp. 879-886 ◽  
Author(s):  
Molly Stout ◽  
Julia López ◽  
Ryan Colvin ◽  
George Macones ◽  
Alison Cahill ◽  
...  

Objective The objective of this study was to describe the incidence of baseline change within normal range during labor and its prediction of neonatal outcomes. Materials and Methods This was a prospective cohort of singleton, nonanomalous, term neonates with continuous electronic fetal monitoring and normal baseline fetal heart rate throughout the last 2 hours of labor. We determined baseline in 10-minute segments using Eunice Kennedy Shriver National Institute of Child Health and Human Development criteria. We evaluated baseline changes of ≥ 20 and ≥ 30 bpm for association with acidemia (umbilical cord arterial pH ≤ 7.10) and neonatal intensive care unit (NICU) admission. Finally, we performed a sensitivity analysis of normal neonates, excluding those with acidemia, NICU admission, or 5-minute Apgar < 4. Results Among all neonates (n = 3,021), 1,267 (41.9%) had change ≥ 20 bpm; 272 (9.0%) had ≥ 30 bpm. Among normal neonates (n = 2,939), 1,221 (41.5%) had change ≥20 bpm. Acidemia was not associated with baseline change of any direction or magnitude. NICU admission was associated with decrease ≥ 20 bpm (adjusted odds ratio [aOR]: 2.93; 95% confidence interval [CI]: 1.19 – 7.21) or any direction ≥ 20 bpm (aOR: 4.06; 95% CI: 1.46–11.29). For decrease ≥ 20 bpm, sensitivity and specificity were 40.0 and 81.7%; for any direction ≥ 20 bpm, 75.0 and 58.3%. Conclusion Changes of normal baseline are common in term labor and poorly predict morbidity, regardless of direction or magnitude.


2020 ◽  
Vol 8 ◽  
Author(s):  
Rik Vullings ◽  
Judith O. E. H. van Laar

Fetal monitoring is important to diagnose complications that can occur during pregnancy. If detected timely, these complications might be resolved before they lead to irreversible damage. Current fetal monitoring mainly relies on cardiotocography, the simultaneous registration of fetal heart rate and uterine activity. Unfortunately, the technology to obtain the cardiotocogram has limitations. In current clinical practice the fetal heart rate is obtained via either an invasive scalp electrode, that poses risks and can only be applied during labor and after rupture of the fetal membranes, or via non-invasive Doppler ultrasound technology that is inaccurate and suffers from loss of signal, in particular in women with high body mass, during motion, or in preterm pregnancies. In this study, transabdominal electrophysiological measurements are exploited to provide fetal heart rate non-invasively and in a more reliable manner than Doppler ultrasound. The performance of the fetal heart rate detection is determined by comparing the fetal heart rate to that obtained with an invasive scalp electrode during intrapartum monitoring. The performance is gauged by comparing it to performances mentioned in literature on Doppler ultrasound and on two commercially-available devices that are also based on transabdominal fetal electrocardiography.


2019 ◽  
Vol 67 (2) ◽  
pp. 274-281
Author(s):  
Lea Lénárt ◽  
Marcel Taverne ◽  
Peter Wolleswinkel ◽  
Zoltán Gubik ◽  
László Molnár ◽  
...  

The aim of this study was to create a fetal heart rate (FHR) reference curve for singleton bovine fetuses in the first trimester of gestation and to determine its possible relationship with the outcome of pregnancy. Forty-eight Holstein-Friesian cows with one fetus and five cows with twins were used. Fetal heart beatings were recorded on videotape during transrectal scanning with a 5 and/or 7.5 MHz linear array transducer on a weekly basis between Days 40 and 95 of gestation. FHR was calculated by averaging the results of five counts of the same record by the same observer. For singleton pregnancies, a reference curve was created using the mean, the standard deviation (SD) and the 5th and 95th percentiles. The FHR increased from Days 40–46 (173 beats/min) to Days 61–67 (183 beats/min). After a peak, the FHR decreased slowly until Days 89–95 (175 beats/min), while the SD increased. There was no significant difference between singleton and twin fetuses. in the aborted and lost fetuses in twin gestation due to fetal reduction, both bradycardia and tachycardia were detected compared to the singleton pregnancy reference curve.


2014 ◽  
Vol 218 (02) ◽  
pp. 80-86
Author(s):  
V. Roemer ◽  
R. Walden

Abstract Background: Using the naked eye evaluation of fetal heart rate (fhr) patterns remains difficult and is not complete. Computer-aided analysis of the fhr offers the opportunity to analyze fhr patterns completely and to detect all changes due to hypoxia and acidosis. It was the goal of this study to analyze the factor time in fetal monitoring and to evaluate the association between the fhr and the actual pH values in arterial umbilical blood. Methods: During a period of 11 years the FHR signals (i. e., the R-R interval of the F-ECG) of 646 fetuses were recorded with a CTG and simultaneously by a computer. The computer files were analyzed thereafter, i. e., the results did not influence our clinical management. To enter the study, all fetuses must have been delivered by the vaginal route – in consequence without a significant loss of fhr signals. During forceps and/or vacuum deliveries recordings were continued. If necessary a new electrode was inserted. In this study recordings of fetuses with chorioamnionitis, tracings of malformed neonates and tracings shorter than 30 min were excluded. Thus 484 recordings were left. We used our own computer programs written in MATLAB (USA). 3 parameters were determined electronically: 1) the mean fetal frequency [fhf, (bpm)], 2) the number of turning points (N/min) in the fhr, which we called ‘microfluctuation’ (micro) and 3) the oscillation amplitude, oamp (bpm). Measurements of the acid-base variables from arterial (UA) and venous (UV) blood were performed using RADIOMETER equipment (ABL500) and trained personnel. However, only the actual pHUA values were used in this study. To detect the influence of hypoxia and acidosis, all 484 cases were separated into 7 groups according to the actual pHUA value: 55 fetuses lying in a small non-acidotic “pH-window” (pHUA=7.290–7.310, mean=7.300±0.008) were used as ‘controls’. Results: In humans fhf, micro and the oamp behave differently during the last 30 min of delivery and with different fetal pHUA values: micro is early (at 0 min) decreased with fetal acidemia and is steadily deceasing (68–40 N/min) during vaginal delivery; the oamp – mainly due to decelerations – is increased from 35 up to 70 bpm during the last 30 min. Hypoxia and acidosis increase the amplitude and duration of decelerations; finally fhf shows only an insignificant reaction to acidemia but is decreased (from 135 to 110 bpm) overall with the course of time. Therefore the 3 characteristics of the fhr might be ranged according to their decreasing sensitivity to acidemia as follows: 1) fetal microfluctuation, 2) oscillation amplitude and 3) mean frequency. The 3 components of the fhr were used to invent and apply a score named the WAS score. This score increases the association between the actual pHUA values and the activity of the fetal heart. The 3 variables of the fhr mentioned above were rated differently; the 3 factors necessary to achieve this were computed electronically using an optimization program. The result is the WAS score: WAS=mean [frq*ff(vj) * micro*fm (vj)/oamp*fa(vj)]j=1,30. Using the last 30 min of delivery the correlation coefficient r of this score with pHUA reaches 0.645, P<< 0.001. The regression is linear in our 484 cases. Conclusions: Microfluctuation is the most sensible variable of the fetal heart followed by the oscillation amplitude and mean frequency. The WAS score offers the best correlation with the actual pH values measured in arterial umbilical blood.


2019 ◽  
Vol 37 (04) ◽  
pp. 378-383
Author(s):  
Ebony B. Carter ◽  
Cheryl S. Chu ◽  
Zach Thompson ◽  
Methodius G. Tuuli ◽  
George A. Macones ◽  
...  

Objective This study aimed to determine the association between nuchal cord, electronic fetal monitoring parameters, and adverse neonatal outcomes. Study Design This was a prospective cohort study of 8,580 singleton pregnancies. Electronic fetal monitoring was interpreted, and patients with a nuchal cord at delivery were compared with those without. The primary outcome was a composite neonatal morbidity index. Logistic regression was used to adjust for confounders. Result Of 8,580 patients, 2,071 (24.14%) had a nuchal cord. There was no difference in the risk of neonatal composite morbidity in patients with or without a nuchal cord (8.69 vs. 8.86%; p = 0.81). Nuchal cord was associated with category II fetal heart tracing and operative vaginal delivery (OVD) (6.4 vs. 4.3%; p < 0.01). Conclusion Nuchal cord is associated with category II electronic fetal monitoring parameters, which may drive increased rates of OVD. However, there is no significant association with neonatal morbidity.