scholarly journals Intraoral Repair of All Ceramic Fixed Partial Denture Utilizing Preimpregnated Fiber Reinforced Composite

2008 ◽  
Vol 02 (01) ◽  
pp. 63-68
Author(s):  
Süha Turkaslan ◽  
Arzu Tezvergil-Mutluay

ABSTRACTAll ceramic fixed partial dentures (FPD)s exhibit enhanced biocompatibility and esthetics as compared to metal-ceramic restorations. However, framework fractures are frequently reported especially when the connector dimensions are inadequate to withstand the high tensile stresses. The repair of the failed connector would be desirable rather than the complete removal and renewal since the latter is an expensive and time consuming procedure. Furthermore, the replacement or removal of the restoration for extra-oral repair purposes might increase the risk of destroying the entire restoration or damaging the abutment teeth during the removal. This article presents a direct intra-oral method that may be used to repair the connector fractures of all-ceramic FPDs which are otherwise clinically satisfactory. In the present technique, the connector is reconstructed intraorally utilizing composite resin restorative material reinforced with E-glass-fiber. (Eur J Dent 2008;2:63-68)

2014 ◽  
Vol 40 (S1) ◽  
pp. 371-374
Author(s):  
Yoshiyuki Hagiwara ◽  
Tatsuya Narita ◽  
Masao Araki ◽  
Kunihiko Sawada ◽  
Kiyoshi Nakajima

Even in the case of implant loss, replacement of the implant and refabrication of the superstructure are often sufficient, as long as the bone and soft tissue are in good condition. However, if implant loss accompanied by serious bone resorption occurs with a fixed implant superstructure supported by multiple implants, it is very difficult to treat. This clinical report describes the process by which multiple implant-supported fixed metal ceramic restorations were repaired with a metal ceramic resin-bonded fixed partial denture without complete refabrication after removal of one of the implants due to severe bone resorption. The 3-year follow-up indicated excellent serviceability and a well-satisfied patient.


2008 ◽  
Vol 32 (4) ◽  
pp. 283-291 ◽  
Author(s):  
Andréa Barreira Motta ◽  
Luiz Carlos Pereira ◽  
Andréia R.C.C. da Cunha ◽  
Fernando Pereira Duda

2010 ◽  
Vol 11 (4) ◽  
pp. 63-70 ◽  
Author(s):  
Ralf Kollefrath ◽  
Marcel Savary ◽  
Jörg Schwela

Abstract Aim To demonstrate the clinical feasibility of autoclaving certain silicone impression materials in order to avoid potential cross-contamination during handling, transport, and subsequent processing. Background Semicritical devices are recommended to be treated at least with high-level disinfectants or actually steam sterilized at 134°C. To date dental impressions have been disinfected rather than sterilized, so the question remains should they be sterilized before being sent to the dental laboratory? Case Descriptions Two identical impressions per case were made of metal-ceramic crown and fixed partial denture preparations on the same patient using addition type polyvinyl siloxane (PVS) impression materials (AFFINIS, R Coltene/ Whaledent AG, 9450 Altstatten, Switzerland) in different trays. The first impression (IMPx1) was cleaned and treated with an intermediate-level disinfectant (FD 322.Fast Disinfection Spray, Durr Dental, 74321 Bietigheim-Bissingen, Germany). The second impression (IMPx2) was cleaned, treated with an intermediate-level disinfectant as with IMPx1, subjected to a computer tomography (CT) scan with a dimensional resolution of ±10 μm, steam sterilized, and then subjected to a second CT scan. The dimensional changes of the second impression after steam sterilization were calculated by comparing the overlay of the two CT scans and expressed by color coding of the impression graphics. After the second scan, the impression was sent to a dental laboratory to fabricate a metal-ceramic crown or metal-ceramic fixed partial denture restoration to the one produced from the first impression (IMPx1) subjected only to disinfection. This process was repeated for four clinical cases. Conclusion Impressions made with AFFINIS® silicone impression materials in a rigid reinforced polycarbonate impression tray or in a metal dual-arch tray can be autoclaved. The overall dimensional stability of the impressions and the quality of single crowns and small fixed partial dentures made using IMPx2 was not compromised. The maximum dimensional differences at the preparations of the nonautoclaved and the autoclaved impressions were found to be within acceptable limits of about 50–100 ìm. Clinical Significance Steam sterilization of AFFINIS® impressions is possible without adversely affecting dimensional change. In addition, clinicians can clearly indicate to the dental practice and laboratory personnel that sterilization of the impressions has been performed, cross-contamination is unlikely, and the impressions present no apparent health hazard during transport and subsequent processing. Disclosure Dr. Kollefrath is head of Research and Development, Elastomers at Coltène/ Whaledent AG, Altstätten, Switzerland, the manufacturer of the impression material evaluated in this report. Citation Kollefrath R, Savary M, Schwela J. An Evaluation of the Fit of Metal-Ceramic Restorations Made with an Autoclaved Silicone- Based Impression Material. J Contemp Dent Pract [Internet]. 2010 July; 11(4):063-070. Available from: http://www.thejcdp.com/journal/ view/volume11-issue4-kollefrath


2013 ◽  
Vol 07 (02) ◽  
pp. 233-238
Author(s):  
Bulent Uludag ◽  
Emre Tokar ◽  
Serdar Polat

ABSTRACTHigh-strength all-ceramic materials are commonly used in dentistry. When complications occur in an all-ceramic restoration, the restoration is usually replaced. This article describes the time-saving ability and cost-effectiveness of this novel technique for the addition of a pontic in two complicated clinical cases. Turkom-CeraTM [Turkom-Ceramic (M) Sdn. Bhd.] with aluminum oxide (99.98%) is an all-ceramic system that offers the option of addition of a new pontic to the sintered framework. The new pontic was cut off from an alumina blank [Turkom-Ceramic (M) Sdn. Bhd.], moistened, and attached to the framework using alumina gel [Turkom-Ceramic (M) Sdn. Bhd.]. The framework was veneered with veneering porcelain (Vita VM 7; VITA Zahnfabrik). The two cases presented here involving the addition of a pontic to sintered framework were followed up for at least 1 year. No complication was detected or reported by the patients. Alumina- and zirconia-based ceramics are particularly suitable for for all-ceramic restorations in high-stress bearing areas. However, replacement of a failed all-ceramic restoration is not the most practical solution, considering both cost and tooth-related factors. This attractive feature of the Turkom-Cera allows the repair of a fractured ceramic coping or the addition of a new pontic to restorations.


2012 ◽  
Vol 06 (01) ◽  
pp. 101-104 ◽  
Author(s):  
Haluk Baris Kara ◽  
Filiz Aykent

ABSTRACTThis article describes the use of an all ceramic resin-bonded fixed partial denture as a conservative solution for the replacement of an incisor. It is a minimally invasive technique that does not discolor the abutment teeth. (Eur J Dent 2012;6:101-104)


Author(s):  
Sriram Thirugnanam

Aim: To describe a protocol to replace few missing anterior teeth with periodontally compromised abutments. Background: Due to their lower modulus of elasticity, fibre reinforced composites (FRCs) minimize the stress level at the tooth restoration interface and enable an adjustment of the framework’s mechanical properties by inserting adequate fibre volumes. Direct and semi-direct fabricated FRC Fixed Dental Prosthesis (FDP) now compete successfully with conventional cast metal resin-bonded FDPs. Case Description: A Fibre Reinforced Composite(FRC) bridge was given to replace missing 31 and 41. The FRC material was bonded from canine to canine (33-43) to ensure the stability of the periodontally compromised abutment teeth by acting as a splint with minimal intervention. Conclusion: Fiber-reinforced composite restorations reduce the number of appointments and make single visit dentistry possible especially when the abutments are periodontally compromised and require splinting. Clinical Significance: This case report demonstrates the benefits of splinting periodontally compromised abutment teeth.


Ceramics ◽  
2021 ◽  
Vol 4 (2) ◽  
pp. 199-207
Author(s):  
Lohitha Kalluri ◽  
Bernard Seale ◽  
Megha Satpathy ◽  
Josephine F. Esquivel-Upshaw ◽  
Yuanyuan Duan

This study was performed as an adjunct to an existing clinical study to validate the effect of veneer: framework thickness ratio on stress distribution in an implant-supported all-ceramic fixed partial denture. Two commercially available titanium dental implants with corresponding customized abutments and a patient-retrieved all-ceramic fixed partial denture were scanned using a high-resolution micro-CT scanner. Reconstructed 3D objects, along with a simulated bone surface, were incorporated into a non-manifold assembly and meshed simultaneously using Simpleware software (Synopsys Simpleware ScanIP Version P-2019.09; Mountain View, CA). Three such volume meshes (Model A, Model B, Model C) corresponding to veneer: framework thickness ratios of 3:1, 1:1, and 1:3 respectively were created, and exported to a finite element analysis software (ABAQUS). An axial load of 110 N was applied uniformly on the occlusal surfaces to calculate the static stresses and contour plots were generated in the post-processing module. From the data obtained, we observed optimum stress distribution in Model B. Also, the tensile stresses were concentrated in the posterior connector region of the prosthesis in all three models tested. Within the limitations of this study, we can conclude that equal thickness of veneer and framework layers would aid in better stress distribution.


Sign in / Sign up

Export Citation Format

Share Document