Arthroscopic Removal of a Missed Wooden Foreign Body in the Metacarpophalangeal Joint

Author(s):  
Sotetsu Sakamoto ◽  
Kazuteru Doi ◽  
Yasunori Hattori ◽  
Sam Supreeth ◽  
Shichoh Sonezaki ◽  
...  

AbstractWe report a case of a missed wooden foreign body in the metacarpophalangeal (MP) joint of the right little finger following a workplace injury. The patient presented to our institution with a persisted pain and limited range of motion of the MP joint 1 week following the injury. Plain radiographs detected no foreign body or fractures. However, detailed examination as ultrasonography (USG) and computed tomography revealed the presence of a foreign body of 10 × 1.5 mm size in the MP joint capsule. The excision of the radiolucent foreign body was performed arthroscopically and was confirmed successful removal using intraoperative USG. The foreign body was recognized as a wooden piece. The patient was immediately pain free postoperatively and regained full range of motion. Arthroscopy can be a practical, reliable method to remove a radiolucent foreign body located in a small joint in a minimally invasive manner, and USG can help surgeons confirm no remnants left.

2016 ◽  
Vol 30 (1) ◽  
pp. 88-91 ◽  
Author(s):  
Alfredo Di Gaeta ◽  
Francesco Giurazza ◽  
Eugenio Capobianco ◽  
Alvaro Diano ◽  
Mario Muto

To identify and localize an intraorbital wooden foreign body is often a challenging radiological issue; delayed diagnosis can lead to serious adverse complications. Preliminary radiographic interpretations are often integrated with computed tomography and magnetic resonance, which play a crucial role in reaching the correct definitive diagnosis. We report on a 40 years old male complaining of pain in the right orbit referred to our hospital for evaluation of eyeball pain and double vision with an unclear clinical history. Computed tomography and magnetic resonance scans supposed the presence of an abscess caused by a foreign intraorbital body, confirmed by surgical findings.


2018 ◽  
Vol 2018 ◽  
pp. 1-4
Author(s):  
Koichi Yano ◽  
Yasunori Kaneshiro ◽  
Hideki Sakanaka

A 24-year-old right-handed man suffered right olecranon and lateral epicondylar fracture from high energy trauma. Fixation of olecranon was performed by a previous doctor. Three months after operation, he presented with limited range of motion (ROM) of the right elbow caused by malunion of the lateral epicondylar fracture and subluxation of the radiohumeral joint. Preoperative ROM of the right elbow was flexion 110° and extension −75°. Forearm rotation was pronation 85° and supination 65°. Fragment excision of the lateral epicondyle, which was 27 mm in length, and lateral collateral ligament repair using anchors were performed. Fourteen months postoperatively, contracture release of the elbow was performed. Twenty-four months postoperatively, radiograph of the elbow showed normal congruence without osteoarthritic changes and the ROM of the right elbow was flexion 120° and extension −35°. Forearm rotation was pronation 90° and supination 70°. In the surgical setting, in case of the size of the lateral epicondylar fragment is relatively large, the fragment should be fixed or lateral collateral ligament should be repaired when the instability of the elbow is found.


Author(s):  
Derek Lura ◽  
Rajiv Dubey ◽  
Stephanie L. Carey ◽  
M. Jason Highsmith

The prostheses used by the majority of persons with hand/arm amputations today have a very limited range of motion. Transradial (below the elbow) amputees lose the three degrees of freedom provided by the wrist and forearm. Some myoeletric prostheses currently allow for forearm pronation and supination (rotation about an axis parallel to the forearm) and the operation of a powered prosthetic hand. Older body-powered prostheses, incorporating hooks and other cable driven terminal devices, have even fewer degrees of freedom. In order to perform activities of daily living (ADL), a person with amputation(s) must use a greater than normal range of movement from other body joints to compensate for the loss of movement caused by the amputation. By studying the compensatory motion of prosthetic users we can understand the mechanics of how they adapt to the loss of range of motion in a given limb for select tasks. The purpose of this study is to create a biomechanical model that can predict the compensatory motion using given subject data. The simulation can then be used to select the best prosthesis for a given user, or to design prostheses that are more effective at selected tasks, once enough data has been analyzed. Joint locations necessary to accomplish the task with a given configuration are calculated by the simulation for a set of prostheses and tasks. The simulation contains a set of prosthetic configurations that are represented by parameters that consist of the degrees of freedom provided by the selected prosthesis. The simulation also contains a set of task information that includes joint constraints, and trajectories which the hand or prosthesis follows to perform the task. The simulation allows for movement in the wrist and forearm, which is dependent on the prosthetic configuration, elbow flexion, three degrees of rotation at the shoulder joint, movement of the shoulder joint about the sternoclavicular joint, and translation and rotation of the torso. All joints have definable restrictions determined by the prosthesis, and task.


Open Medicine ◽  
2013 ◽  
Vol 8 (6) ◽  
pp. 810-813
Author(s):  
C. Garving ◽  
T. Dienstknecht ◽  
K. Horst ◽  
M. Pishnamaz ◽  
P. Kobbe ◽  
...  

AbstractIntroduction. Bilateral posterior dislocation of the shoulder is a rare injury, accounted for about 2–5% of all shoulder dislocations. Main courses are electrical shock, epilepsy or extreme trauma with uncontrolled muscle forces. We report about a case of bilateral posterior shoulder dislocation without additional fractures but with a concomitant acromioclavicular joint dislocation. Case presentation. A 46-year-old Caucasian motorcyclist presented to our facility after a fall on slippery ground. He claimed pain in both shoulders with limited range of motion. The initial X-rays were inconclusive, clinical examination showed typical findings of a Rockwood injury with an additional limited external rotation so that a posterior shoulder dislocation was suspected. The CT scan confirmed the clinical suspicion. A closed reduction was performed followed by immobilization in a shoulder abduction pillow for 4 weeks and continuous physiotherapy. Upon follow up normal function with full range of motion was observed. Conclusion. A bilateral posterior shoulder dislocation can be caused by trauma and results in a limited range of motion with often additional injuries. Due to the unusually presentation the risk of missing the injury is increased. Therefore it is most important to consider this rare diagnosis and in case of clinical suspicion perform a careful algorithm of diagnostic.


1959 ◽  
Vol 81 (2) ◽  
pp. 126-130
Author(s):  
Kurt Hain ◽  
Gerhard Marx

A practical method is shown for designing four-bar mechanisms having a prescribed transmission ratio held within prescribed tolerances, for a limited range of motion. Such mechanisms may economically replace gears in many applications. Charts enable the designer to choose the mechanism having the best transmission angle possible.


2014 ◽  
Vol 2014 ◽  
pp. 1-4
Author(s):  
Cuneyd Gunay ◽  
Ebru Atalar ◽  
Baybars Ataoglu

Charcot arthropathy is a chronic, degenerative condition and is associated with decreased sensorial innervation. Numerous causes of this arthropathy have been described. Here we report a case of neuropathic arthropathy secondary to syringomyelia which was misdiagnosed as a soft tissue tumor and treated surgically and additionally with radiotherapy at another institution. The patient had clinical and radiological signs of syringomyelia, associated with a limited range of motion, swelling, and pain in the affected joint. Neuropathic arthropathy, although less common, should be considered in cases of unexplained joint swelling, pain, and limited range of motion of the affected joint.


1992 ◽  
Vol 24 (1) ◽  
pp. 128???133 ◽  
Author(s):  
JAMES E. GRAVES ◽  
MICHAEL L. POLLOCK ◽  
SCOTT H. LEGGETT ◽  
DAVID M. CARPENTER ◽  
CECILY K. FIX ◽  
...  

2012 ◽  
Vol 134 (5) ◽  
Author(s):  
Nevan C. Hanumara ◽  
Alexander H. Slocum ◽  
Takeshi Mitamura

This paper presents the development of a mechanism for actuating a sphere holonomically about 3 degrees of freedom (DOF). The target application is a robot head for mounting inside a vehicle to provide a driver with companionship, location specific information, and other assistance, via head motions in conjunction with auditory communication. Prior art is reviewed and two designs are presented: One mechanism is located below the sphere and provides an unlimited range of motion (ROM), and the other is contained entirely within the sphere but has a limited range of motion. The latter is stable and easily mounted, provides a clean appearance, and is particularly suited to human interaction applications.


Sign in / Sign up

Export Citation Format

Share Document