Effect of Individual Time to Peak Power Output on the Expression of Peak Power Output in the 30-s Wingate Anaerobic Test

2007 ◽  
Vol 28 (2) ◽  
pp. 135-139 ◽  
Author(s):  
W. Bell ◽  
D. Cobner
2006 ◽  
Vol 31 (3) ◽  
pp. 186-189 ◽  
Author(s):  
Juan Del Coso ◽  
Ricardo Mora-Rodríguez

To validate the measurement of peak power output (PPO) using a short cycling sprint test (inertial load (IL) test), we compare it to the widely accepted Wingate anaerobic test (WAnT). Fifteen healthy, young, active subjects performed 2 experimental trials. In each trial, subjects warmed up and sprinted 4 times for the IL test. After recovery, they cycled for 30 s at maximum capacity for the WAnT. The experimental trial was replicated 3 d later to test for reliability. Inter- and intra-day PPO measured with the IL test was very reliable (R1 = 0.99 and R1 = 0.94, respectively). The correlation between the IL and WAnT was highly significant (r = 0.82; P < 0.001), although the absolute PPO values were markedly higher for the IL test (1268 ± 41 W vs. 786 ± 27 W; P < 0.001). In conclusion, cycling PPO can be validly assessed with the IL test. The higher PPO attained with an IL test could be related to better identification of peak power, since both velocity and resistance are free to vary during the sprint in comparison with the WAnT, where resistance is fixed. Owing to the short duration of the sprint (4 s) and high intra-day reliability despite a short recovery time (180 s), the IL test is optimal for repeated measurements of anaerobic performance.Key words: inertial load, neuromuscular power, cycle ergometer, intra-day reliability, performance.


2000 ◽  
Vol 12 (1) ◽  
pp. 91-100 ◽  
Author(s):  
Nicola C. Sutton ◽  
David J. Childs ◽  
Oded Bar-Or ◽  
Neil Armstrong

The purpose of this study was to develop a nonmotorized treadmill sprint test (ExNMT) to assess children’s short-term power output, to establish the test’s repeatability, and to compare the results to corresponding Wingate anaerobic test (WAnT) measurements. Nineteen children (aged 10.9±0.3 years) completed 2 ExNMTs and 2 WAnTs. Statistical analysis revealed coefficients of repeatability for the ExNMT that compared very favorably with the WAnT for both peak power (26.6 vs. 44.5 W) and mean power (15.3 vs. 42.1 W). The validity of the ExNMT as a test of anaerobic performance is reflected by significant correlations (p ≤.05) with the WAnT (peak power, r = 0.82; mean power, r = 0.88) and reinforced by the relatively high post-exercise blood lactate concentrations (7.1 ± 1.3 vs. 5.6 ± 1.5 mmol · L−1 for the ExNMT and WAnT, respectively). This study has developed a promising laboratory running test with which to examine young people’s short-term power output.


2009 ◽  
Vol 21 (1) ◽  
pp. 47-54 ◽  
Author(s):  
Myriam Guerra ◽  
Maria Giné-Garriga ◽  
Bo Fernhall

The Wingate anaerobic test (WAnT) has not been used to assess individuals with Down syndrome (DS) and it is unknown if it is reliable in this population. We investigated the reliability of the WAnT in 19 adolescents with DS (age = 14.8 yrs; weight = 52.7 kg; height = 146.3 cm). Participants completed, on separate days, two standards WAnT using a resistance of 0.7 Nm × body weight (kg) in individuals ≥ 14 years old, and 0.5 Nm × body weight (kg) in participants < 14 years of age. Data were analyzed using intraclass correlation coefficient (ICC), dependent t tests and Bland-Altman plots. There was a significant difference between days for peak power (210.37 W vs. 236.26 W; ICC = 0.93), but not for mean power (158.72 vs. 168.71 W; ICC = 0.86), time to peak power (6.67 vs. 6.28 s; ICC = 0.69), or the fatigue index (9.33 vs. 5.43 W/sec; ICC = 0.09). Adolescents with DS exhibit low WAnT performance compared with previously published data on adolescents without DS and the reliability of WAnT is questionable in this population.


Circulation ◽  
2021 ◽  
Vol 143 (Suppl_1) ◽  
Author(s):  
Colin Carriker ◽  
Phillip Armentrout ◽  
Sarah Levine ◽  
James Smoliga

Introduction: Previous studies have examined dietary nitrate supplementation and its effects on dry static apnea, and peak power. Dietary nitrate supplementation has been found to increase maximal apnea and peak power output. The purpose of this study was to determine the effects of beetroot juice on dry static apnea and Wingate performance. Hypothesis: Dietary nitrate will improve maximal breath hold time and peak power output. Dietary nitrate will improve tolerance to CO2, thereby improving maximal breath hold time and anaerobic capacity. Methods: In a randomized, double-blind, counterbalanced study, five healthy males (20.4±0.89 years) visited the lab on 3 separate occasions each separated by one week. Visit 1 served as a Wingate and breath hold familiarization visit. Prior to visits 2 and 3 participants were instructed to drink a beverage either a placebo (negligible nitrate content, PL) or dietary nitrate rich beverage (12.4 mmol nitrate, NIT) during the 4 days leading up to their next visit. Visits 2 and 3 consisted of two submaximal breath holds (80% of maximal determined during visit 1), with 2 minutes of rest between and three minutes of rest preceding the final breath hold for maximal duration. Finally, participants completed a standardized 10-minute warmup on the cycle ergometer before completing a 30-second maximal effort Wingate test. Results: A linear mixed effects model was used to determine whether treatment (NIT vs. PL) was associated with differences in VCO2 or PetCO2. Time (0, 10, 20, 30 min post-breath hold) and Treatment both served as repeated measures. Models were developed using multiple repeated measures covariance matrix structures, and the model with the lowest AIC was chosen as the final model. The interaction between time and treatment was included in the original models, and was removed if it was not statistically significant. Time was a statistically significant factor for VCO2 and PetCO2 (p < 0.001). Treatment, and the Time x Treatment interaction was not significant for either variable. No differences between NIT and PL were observed during the Wingate test for either time to peak power (5.02±2.45 and 6.2±2.43 sec, respectively) or maximal power (9.73±1.01 and 9.72±1.03 watts/kg, respectively) and fatigue index (49.42±14.98 and 47.30±6.99 watts/sec, respectively). Conclusion: Preliminary data indicates that in a general population four days of dietary nitrate supplementation may not improve breath hold time, tolerance to carbon dioxide in the lungs, or Wingate performance.


1996 ◽  
Vol 271 (2) ◽  
pp. C676-C683 ◽  
Author(s):  
J. J. Widrick ◽  
S. W. Trappe ◽  
D. L. Costill ◽  
R. H. Fitts

Gastrocnemius muscle fiber bundles were obtained by needle biopsy from five middle-aged sedentary men (SED group) and six age-matched endurance-trained master runners (RUN group). A single chemically permeabilized fiber segment was mounted between a force transducer and a position motor, subjected to a series of isotonic contractions at maximal Ca2+ activation (15 degrees C), and subsequently run on a 5% polyacrylamide gel to determine myosin heavy chain composition. The Hill equation was fit to the data obtained for each individual fiber (r2 > or = 0.98). For the SED group, fiber force-velocity parameters varied (P < 0.05) with fiber myosin heavy chain expression as follows: peak force, no differences: peak tension (force/fiber cross-sectional area), type IIx > type IIa > type I; maximal shortening velocity (Vmax, defined as y-intercept of force-velocity relationship), type IIx = type IIa > type I; a/Pzero (where a is a constant with dimensions of force and Pzero is peak isometric force), type IIx > type IIa > type I. Consequently, type IIx fibers produced twice as much peak power as type IIa fibers, whereas type IIa fibers produced about five times more peak power than type I fibers. RUN type I and IIa fibers were smaller in diameter and produced less peak force than SED type I and IIa fibers. The absolute peak power output of RUN type I and IIa fibers was 13 and 27% less, respectively, than peak power of similarly typed SED fibers. However, type I and IIa Vmax and a/Pzero were not different between the SED and RUN groups, and RUN type I and IIa power deficits disappeared after power was normalized for differences in fiber diameter. Thus the reduced absolute peak power output of the type I and IIa fibers from the master runners was a result of the smaller diameter of these fibers and a corresponding reduction in their peak isometric force production. This impairment in absolute peak power production at the single fiber level may be in part responsible for the reduced in vivo power output previously observed for endurance-trained athletes.


1994 ◽  
Vol 77 (3) ◽  
pp. 1403-1410 ◽  
Author(s):  
R. Callister ◽  
A. V. Ng ◽  
D. R. Seals

We tested the hypothesis that sympathetic vasoconstrictor nerve activity to nonactive skeletal muscle (MSNA) decreases immediately before and remains suppressed during initiation of conventional large muscle upright dynamic exercise in humans. In 11 healthy young subjects, adequate recordings of MSNA from the radial nerve in the arm were obtained during upright seated rest (control) and throughout 1 min of leg-cycling exercise at one or more submaximal workloads (range 33–266 W; approximately 10–80% of peak power output). MSNA was analyzed during four consecutive time intervals; control, preparation for cycling (end of control to onset of pedal movement), initiation of cycling (onset of pedal movement to attainment of target power output), and the initial 60 s of cycling at target power output. MSNA decreased (P < 0.05) abruptly and markedly in all subjects [to 19 +/- 4% (SE) of control levels] during the preparation period before the 33-W load and remained suppressed throughout the period of initiation of cycling in 8 of 11 subjects; MSNA increased during the initiation period in three subjects in whom diastolic arterial pressure fell below control levels. This general pattern was observed at all loads. MSNA remained at or below control levels throughout the 1 min of cycling exercise at 33–166 W. MSNA increased above control levels during the latter portion of the 1 min of cycling only at loads > or = 60% of peak power output.(ABSTRACT TRUNCATED AT 250 WORDS)


2015 ◽  
Vol 29 (10) ◽  
pp. 2919-2925 ◽  
Author(s):  
Boris Metikos ◽  
Pavle Mikulic ◽  
Nejc Sarabon ◽  
Goran Markovic

Sign in / Sign up

Export Citation Format

Share Document