Filter System for Intravenous Alimentation

1973 ◽  
Vol 289 (9) ◽  
pp. 487-487 ◽  
Author(s):  
J.T. Czernuszka ◽  
N.J. Long ◽  
P.B. Hirsch

In the 1970s there was considerable interest in the development of the electron channelling contrast imaging (ECCI) technique for imaging near surface defects in bulk (electron opaque) specimens. The predictions of the theories were realised experimentally by Morin et al., who used a field emission gun (FEG) operating at 40-50kV and an energy filter such that only electrons which had lost no more than a few 100V were detected. This paper presents the results of a set of preliminary experiments which show that an energy filter system is unneccessary to image and characterise the Burgers vectors of dislocations in bulk specimens. The examples in the paper indicatethe general versatility of the technique.A VG HB501 STEM with a FEG was operated at 100kV. A single tilt cartridge was used in the reflection position of the microscope. A retractable back-scattered electron detector was fitted into the secondary electron port and positioned to within a few millimetres of the specimen. The image was acquired using a Synoptics Synergy framestore and digital scan generator and subsequently processed using Semper 6. The beam divergence with the specimen in this position was 2.5 mrads with a spot size of approximately 4nm. Electron channelling patterns were used to orientate the sample.


2019 ◽  
Vol 67 (6) ◽  
pp. 483-492
Author(s):  
Seonghyeon Baek ◽  
Iljae Lee

The effects of leakage and blockage on the acoustic performance of particle filters have been examined by using one-dimensional acoustic analysis and experimental methods. First, the transfer matrix of a filter system connected to inlet and outlet pipes with conical sections is measured using a two-load method. Then, the transfer matrix of a particle filter only is extracted from the experiments by applying inverse matrices of the conical sections. In the analytical approaches, the one-dimensional acoustic model for the leakage between the filter and the housing is developed. The predicted transmission loss shows a good agreement with the experimental results. Compared to the baseline, the leakage between the filter and housing increases transmission loss at a certain frequency and its harmonics. In addition, the transmission loss for the system with a partially blocked filter is measured. The blockage of the filter also increases the transmission loss at higher frequencies. For the simplicity of experiments to identify the leakage and blockage, the reflection coefficients at the inlet of the filter system have been measured using two different downstream conditions: open pipe and highly absorptive terminations. The experiments show that with highly absorptive terminations, it is easier to see the difference between the baseline and the defects.


1997 ◽  
Vol 36 (6-7) ◽  
pp. 125-132 ◽  
Author(s):  
Toshiya Komatsu ◽  
Jun Shinmyo ◽  
Kiyoshi Momonoi

Tetrachloroethylene (PCE) is one of the most common groundwater contaminants in Japan. PCE can be completely dechlorinated to ethylene (ETY) and ethane (ETA) by anaerobic microorganisms in the presence of a suitable electron donor. This study was conducted to examine the feasibility of using an anaerobic filter for the degradation of PCE in a bioremediation process. Laboratory-scale anaerobic filters were operated at 25°C using ethanol as the electron donor. Rapid start-up of the reactors was achieved by using anaerobic completely PCE-dechlorinating enrichment cultures as the inoculum. During the continuous operating periods, low concentrations (2.8 mg/L) of PCE were almost completely dechlorinated to ETY and ETA at hydraulic retention times of 49-15 hours with 100 mgCOD/L of ethanol. PCE concentrations as high as 80 mg/L was dechlorinated to ETY with a relatively low supply (200 mgCOD/L) of ethanol. Results of this study suggest that the anaerobic filter system is a feasible bioremediation process for the cleanup of groundwater which is contaminated by chlorinated ethylenes.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Axel Boese ◽  
Alexander Wagner ◽  
Alfredo Illanes ◽  
Uwe Bernd Liehr ◽  
Johann Jakob Wendler ◽  
...  

AbstractPhotodynamic diagnostic (PDD) is an optical enhancement option for the endoscope to support the detection of cancer, for example in the bladder. In real application PDD efficiency suffers due to the complex accumulation of the photosensitizing drug inside the tumor and the associated processes of heme syntheses to create the fluorescent components needed. To optimize the diagnostic outcome of PDD it would be helpful to predict the optimal time for diagnosis based on measurable precursors. In a previous cell study, we proposed a new filter fluorometer to image the accumulation of the precursors Coproporphyrin III (CP-III) and Uroporphyrin III (UP-III) that metabolize to Protoporphyrin IX (PP-IX) later. This accumulation process can be used to predict the optimal time slot for diagnostic imaging. Therefore, a new filter system was designed to distinguish between CP-III and PP-IX. In this work we tested this filter system in combination with a standard PDD endoscopic imaging system. Goal of this study was to prove the technical feasibility in a non-patient setup to prepare a later clinical study.


2003 ◽  
Vol 2003 (7) ◽  
pp. 138-152
Author(s):  
Gayle P. Van Durme ◽  
Daniel L. Cearley ◽  
Connie J. Leonard ◽  
James H. Clark ◽  
Cyrous Gilani ◽  
...  

Opflow ◽  
2007 ◽  
Vol 33 (8) ◽  
pp. 10-13
Author(s):  
Brian Young ◽  
Darin St. Germain
Keyword(s):  

Author(s):  
Steve Ingistov ◽  
Michael Milos ◽  
Rakesh K. Bhargava

A suitable inlet air filter system is required for a gas turbine, depending on installation site and its environmental conditions, to minimize contaminants entering the compressor section in order to maintain gas turbine performance. This paper describes evolution of inlet air filter systems utilized at the 420 MW Watson Cogeneration Plant consisting of four GE 7EA gas turbines since commissioning of the plant in November 1987. Changes to the inlet air filtration system became necessary due to system limitations, a desire to reduce operational and maintenance costs, and enhance overall plant performance. Based on approximately 2 years of operational data with the latest filtration system combined with other operational experiences of more than 25 years, it is shown that implementation of the high efficiency particulate air filter system provides reduced number of crank washes, gas turbine performance improvement and significant economic benefits compared to the traditional synthetic media type filters. Reasons for improved gas turbine performance and associated economic benefits, observed via actual operational data, with use of the latest filter system are discussed in this paper.


Sign in / Sign up

Export Citation Format

Share Document