scholarly journals Effects of High-Strength Concrete on Progressive Collapse Resistance of Reinforced Concrete Frame

2020 ◽  
Vol 146 (6) ◽  
pp. 04020078 ◽  
Author(s):  
Xiao-Fang Deng ◽  
Shi-Lin Liang ◽  
Feng Fu ◽  
Kai Qian
2011 ◽  
Vol 243-249 ◽  
pp. 717-723
Author(s):  
Jin Gang Xiong ◽  
Yon Kang Zheng ◽  
Guan Min Cai ◽  
Yan Li

In this paper the analysis is conducted to investigate the progressive collapse resistance of typical reinforced concrete(RC) multi-story frame structures, which are designed according to the China code for seismic design of buildings. The analysis results show that the progressive collapse resistance will be enhanced with the seismic fortification intensity increasing. The progressive collapse resistance of RC frame structures with low seismic fortification intensity are poor. This implies that as for RC frame structures with low seismic or non-seismic demand, close attention must be paid to continuity and ductility in order to prevent progressive collapse.


2011 ◽  
Vol 71-78 ◽  
pp. 871-875
Author(s):  
Yong Kang Zheng ◽  
Jin Gang Xiong ◽  
Zhao Qiang Wu ◽  
Yi Nong He

The progressive collapse of the frame structure is simulated with testing a 1/3 scale, 4×2-bay and 3-storey reinforced concrete spatial frame in this paper. The experimental model was designed according to the non-seismic resistance demand, and the middle-side column of the bottom floor was replaced by a mechanical jack to simulate its initial local damage. Based on the experimental results, the applied load process and the load transferring mechanism of the model frame are analyzed. The progressive collapse-resisting performance of reinforced concrete frames with non-seismic demand are obtained.


2016 ◽  
Vol 711 ◽  
pp. 982-988
Author(s):  
Alex Brodsky ◽  
David Z. Yankelevsky

Numerous studies have been conducted on the in plane behavior of masonry infill walls to lateral loading simulating earthquake action on buildings. The present study is focused on a problem that has almost not been studied regarding the vertical (opposed to lateral) in-plane action on these walls. This may be of concern when a supporting column of a multi-storey reinforced concrete frame with infill masonry walls undergoes a severe damage due to an extreme loading such as a strong earthquake, car impact or military or terror action in proximity to the column. The loss of the supporting column may cause a fully or partly progressive collapse to a bare reinforced concrete frame, without infill masonry walls. The presence of the infill masonry walls may restrain the process and prevent the development of a progressive collapse. The aim of the present study is to test the in-plane composite action of Reinforced Concrete (RC) frames with infill masonry walls under vertical loading through laboratory experiments and evaluate the contributions of infill masonry walls, in an attempt to examine the infill masonry wall added resistance to the bare frame under these circumstances. Preliminary results of laboratory tests that have been conducted on reinforced concrete infilled frames without a support at their end, under monotonic vertical loading along that column axis will be presented. The observed damages and failure modes under vertical loading are clearly different from the already known failure modes observed in the case of lateral loading.


2012 ◽  
Vol 174-177 ◽  
pp. 455-459 ◽  
Author(s):  
Xiao Wei Li ◽  
Xue Wei Li ◽  
Xin Yuan

For expedite the development of high titanium heavy slag concrete, eight high titanium heavy slag high strength reinforced concrete (HTHS-HSRC) scale model column are studied. The eight HTHS-HSRC model columns are tested under reversed horizontal force. Primary experimental parameters include axial load ratio varying from 0.3 to 0.5, volumetric ratios of transverse reinforcement ranging from 1.38% to 1.56%, strength of high titanium heavy slag high strength concrete varying from 55.9 to 61.6 N/mm2 and configurations of transverse reinforcement. It is found from the test result that HTHS-HSRC model columns provides comparable seismic performance to those usually used reinforced concrete column in terms of member ductility, hysteretic and energy dissipation capacity. Primary Factors of Displacement Ductility of Model Columns are also discussed.


Sign in / Sign up

Export Citation Format

Share Document