Ablation of Various Candidate Materials for Inertial Fusion Reactor Walls-2: Simple Calculation and Comparison with Experimental Result of Surface Thickness Ablated with Intense Pulsed X-ray of Sandia Z-Pinch Source

2002 ◽  
Author(s):  
Koichi Kasuya
2003 ◽  
Vol 313-316 ◽  
pp. 235-238 ◽  
Author(s):  
K. Kasuya ◽  
A. Kasamatsu ◽  
Y. Kinoshita ◽  
T. Kamiya ◽  
A. Saiki ◽  
...  

Author(s):  
Lifeng Liu ◽  
Shali Xiao ◽  
Jiayu Qian ◽  
Xianbin Huang ◽  
Hongchun Cai
Keyword(s):  
X Ray ◽  

2019 ◽  
Vol 25 (2) ◽  
pp. 404-416 ◽  
Author(s):  
Tharmalingam Sivarupan ◽  
Mohamed El Mansori ◽  
Keith Daly ◽  
Mark Noel Mavrogordato ◽  
Fabrice Pierron

Purpose Micro-focus X-ray computed tomography (CT) can be used to quantitatively evaluate the packing density, pore connectivity and provide the basis for specimen derived simulations of gas permeability of sand mould. This non-destructive experiment or following simulations can be done on any section of any size sand mould just before casting to validate the required properties. This paper aims to describe the challenges of this method and use it to simulate the gas permeability of 3D printed sand moulds for a range of controlling parameters. The permeability simulations are compared against experimental results using traditional measurement techniques. It suggests that a minimum volume of only 700 × 700 × 700 µm3 is required to obtain, a reliable and most representative than the value obtained by the traditional measurement technique, the simulated permeability of a specimen. Design/methodology/approach X-ray tomography images were used to reconstruct 3D models to simulate them for gas permeability of the 3D printed sand mould specimens, and the results were compared with the experimental result of the same. Findings The influence of printing parameters, especially the re-coater speed, on the pore connectivity of the 3D printed sand mould and related permeability has been identified. Characterisation of these sand moulds using X-ray CT and its suitability, compared to the traditional means, are also studied. While density and 3PB strength are a measure of the quality of the moulds, the pore connectivity from the tomographic images precisely relates to the permeability. The main conclusions of the present study are provided below. A minimum required sample size of 700 × 700 × 700 µm3 is required to provide representative permeability results. This was obtained from sand specimens with an average sand grain size of 140 µm, using the tomographic volume images to define a 3D mesh to run permeability calculations. Z-direction permeability is always lower than that in the X-/Y-directions due to the lower values of X-(120/140 µm) and Y-(101.6 µm) resolutions of the furan droplets. The anisotropic permeability of the 3D printed sand mould is mainly due to, the only adjustable, X-directional resolution of the furan droplets; the Y-directional resolution is a fixed distance, 102.6 µm, between the printhead nozzles and the Z-directional one is usually, 280 µm, twice the size of an average sand grain.A non-destructive and most representative permeability value can be obtained, using the computer simulation, on the reconstructed 3D X-ray tomography images obtained on a specific location of a 3D printed sand mould. This saves time and effort on printing a separate specimen for the traditional test which may not be the most representative to the printed mould. Originality/value The experimental result is compared with the computer simulated results.


2010 ◽  
Vol 107 (8) ◽  
pp. 083303 ◽  
Author(s):  
Y. Sakai ◽  
S. Takahashi ◽  
T. Hosokai ◽  
M. Watanabe ◽  
G-H. Kim ◽  
...  
Keyword(s):  
X Ray ◽  

2011 ◽  
Vol 39 (2) ◽  
pp. 686-694 ◽  
Author(s):  
Xiao Delong ◽  
Ding Ning ◽  
Ning Cheng ◽  
Sun Shunkai ◽  
Zhang Yang ◽  
...  

2010 ◽  
Vol 38 (4) ◽  
pp. 626-630 ◽  
Author(s):  
Philip Coleman ◽  
John Thompson ◽  
Mahadevan Krishnan ◽  
Brian L Bures
Keyword(s):  
X Ray ◽  

Sign in / Sign up

Export Citation Format

Share Document