scholarly journals On the influence of hydronic distribution loop on energy performance and indoor thermal comfort for air-to-water heat pump systems in residential buildings

2019 ◽  
Author(s):  
Matteo Dongellini ◽  
Agostino Piazzi ◽  
Gian Luca Morini
2021 ◽  
Vol 945 (1) ◽  
pp. 012066
Author(s):  
Nadzhratul Husna ◽  
Syed Ahmad Farhan ◽  
Mohamed Mubarak Abdul Wahab ◽  
Nasir Shafiq ◽  
Muhammad Taufiq Sharif ◽  
...  

Abstract Malaysia is located in the equator, with a hot and humid climate. The highest temperature recorded during the day was 39 °C, which leads to discomfort among building occupants, in particular, residential buildings, where indoor thermal comfort is of a higher priority compared to other types of buildings. Hence, the thermal performance of the residential roof assembly needs to be improved to lower the indoor temperature and, accordingly, maintain the level of indoor thermal comfort. In view of the need to improve the thermal performance, a silica-aerogel-incorporated rigid board roof insulation material for residential buildings was developed using kapok fibre, high density polyethylene (HDPE) and silica aerogel. The thermal conductivity of the material was measured. The sample with 4 wt. % and 5 wt. % of silica aerogel content obtained the lowest thermal conductivity of 0.04 W/mK. Silica aerogel content of above 4 wt. % did not result in further reduction of the thermal conductivity. Therefore, it can be concluded that the optimum silica aerogel content for the sample was 4 wt. %. Building-Information-Modelling (BIM)based thermal-energy performance evaluation of the material was performed by generating temperature and cooling load data using Integrated Environmental Solution-Virtual Environment to validate the thermal-energy performance of the material, by installing the material within the roof assembly of a residential BIM. Findings indicate that the material can potentially be employed in the future as a roof insulation material to maintain the level of indoor thermal comfort among residential building occupants.


2020 ◽  
Vol 15 (3) ◽  
pp. 163-170
Author(s):  
Rajan KC ◽  
Hom Bahadur Rijal ◽  
Masanori Shukuya ◽  
Kazui Yoshida

The energy use in residential dwellings has been increasing due to increasing use of modern electric appliances to make the lifestyle easier, entertaining and better. One of the major purposes of indoor energy use is for improving indoor thermal environment for adjusting thermal comfort. Along with the use of passive means like the use of mechanical devices, the occupants in any dwellings use active means such as the use of natural ventilation, window opening, and clothing adjustment. In fact, the use of active means when the outdoor environment is good enough might be more suitable to improve indoor thermal environment than the use of mechanical air conditioning units, which necessarily require electricity. Therefore, the people in developing countries like Nepal need to understand to what extent the occupants can use active means to manage their own indoor thermal comfort. The use of active means during good outdoor environment might be an effective way to manage increasing energy demand in the future. We have made a field survey on the occupants’ adaptive behaviors for thermal comfort in a Japanese condominium equipped with Home Energy Management System (HEMS). Online questionnaire survey was conducted in a condominium with 356 families from November 2015 to October 2016 to understand the occupants’ behaviors. The number of 17036 votes from 39 families was collected. The indoor air temperature, relative humidity and illuminance were measured at the interval of 2-10 minutes to know indoor thermal environmental conditions. The occupants were found using different active behaviors for thermal comfort adjustments even in rather harsh summer and winter. Around 80% of the occupants surveyed opened windows when the outdoor air temperature was 30⁰C in free running (FR) mode and the clothing insulation was 0.93 clo when the outdoor air temperature was 0⁰C. The result showed that the use of mechanical heating and cooling was not necessarily the first priority to improve indoor thermal environment. Our result along with other results in residential buildings showed that the adaptive behaviors of the occupants are one of the primary ways to adjust indoor thermal comfort. This fact is important in enhancing the energy saving building design.


2014 ◽  
Vol 14 (1) ◽  
pp. 18-22 ◽  
Author(s):  
Janis Kazjonovs ◽  
Andrejs Sipkevics ◽  
Andris Jakovics ◽  
Andris Dancigs ◽  
Diana Bajare ◽  
...  

Abstract Strategy of the European Union in efficient energy usage demands to have a higher proportion of renewable energy in the energy market. Since heat pumps are considered to be one of the most efficient heating and cooling systems, they will play an important role in the energy consumption reduction in buildings aimed to meet the target of nearly zero energy buildings set out in the EU Directive 2010/31/EU. Unfortunately, the declared heat pump Coefficient of Performance (COP) corresponds to a certain outdoor temperature (+7 °C), therefore different climate conditions, building characteristics and settings result in different COP values during the year. The aim of this research is to investigate the Seasonal Performance factor (SPF) values of air-to-water heat pump which better characterize the effectiveness of heat pump in a longer selected period of time, especially during the winter season, in different types of residential buildings in Latvian climate conditions. Latvia has four pronounced seasons of near-equal length. Winter starts in mid-December and lasts until mid-March. Latvia is characterized by cold, maritime climate (duration of the average heating period being 203 days, the average outdoor air temperature during the heating period being 0.0 °C, the coldest five-day average temperature being −20.7 °C, the average annual air temperature being +6.2 °C, the daily average relative humidity being 79 %). The first part of this research consists of operational air-towater heat pump energy performance monitoring in different residential buildings during the winter season. The second part of the research takes place under natural conditions in an experimental construction stand which is located in an urban environment in Riga, Latvia. The inner area of this test stand, where air-to-water heat pump performance is analyzed, is 9 m2. The ceiling height is 3 m, all external wall constructions (U = 0.16 W/(m2K)) have ventilated facades. To calculate SPF, the experimental stand is equipped with sensors which provide measurements for electricity consumption and gained heat energy.


2021 ◽  
Vol 11 (18) ◽  
pp. 8565
Author(s):  
Jinzhe Nie ◽  
Yuxin Pang ◽  
Congcong Wang ◽  
Han Zhang ◽  
Kuichao Yin

In the field investigation of rural dwellings, it was found that thermal feelings are significantly different with varied envelopes even under the same indoor air temperature, and this paper explores the phenomenon in simulation. Based on building thermal investigations in several villages of North China, a typical energy and environment simulation model for rural residences was developed using DeST, and the hourly parameters of temperature and humidity were used to calculate the adaptive thermal comfort (APMV) of the rooms. The results show that the main reason for the different thermal comfort at the same air temperature is the large difference in the inner surface temperature. By adjusting the insulation thickness of the envelope structure, the relationship between it and the APMV value is obtained. By adjusting the insulation thickness of the enclosure structure and getting the correlation between it and the APMV value, it is obtained that when the heat transfer coefficient of the enclosure structure meets 0.5 W/ (m2−K), the indoors can be in thermal comfort. This paper considers that the indoor air temperature cannot represent the APMV to evaluate the indoor thermal comfort, and the APMV value should be used to evaluate the thermal comfort of the renovated building and calculate the corresponding energy saving rate.


2021 ◽  
Vol 2069 (1) ◽  
pp. 012069
Author(s):  
Yuchen Yang ◽  
Vahid M. Nik

Abstract In recent years, climate change has been widely recognized as a potential problem. The building industry is taking a variety of actions towards sustainable development and climate change mitigation, such as retrofitting buildings. More than mitigation, it is important to account for climate change adaptation and investigate the probable risks and limits for mitigation strategies. For example, one major challenge may become achieving low energy demand without compromising indoor thermal comfort during warm seasons. This work investigates the future energy performance and indoor thermal comfort of four European cities belonging to four different climate zones in Europe; Barcelona, Koln, Brussels, and Copenhagen. An ensemble of future climate scenarios is used, including thirteen climate scenarios considering five different general circulation models (GCM) and three representative concentration pathways (RCP 2.6, RCP 4.5 and RCP 8.5). Through simulating the energy performance of the representative buildings in each city and considering several climate scenarios, this paper provides a comprehensive picture about the energy performance and indoor thermal comfort of the buildings for near-term, medium-term, and long-term climate conditions.