Coupled vibration of passenger and lightweight car-body in consideration of human-body biomechanics

2006 ◽  
Vol 44 (sup1) ◽  
pp. 601-611 ◽  
Author(s):  
M. Nagai ◽  
H. Yoshida ◽  
T. Tohtake ◽  
Y. Suzuki
Author(s):  
Qinglie He ◽  
Yun Yang ◽  
Chengbiao Cai ◽  
Shengyang Zhu ◽  
Wanming Zhai

Suspended monorail transportation (SMT) plays an important role in alleviating the urban traffic pressure, and its vehicle–bridge dynamic features are significantly different from those of the traditional railway. To grasp the coupled vibration features of suspended monorail train–bridge system (SMTBS), this paper presents a comprehensive experimental investigation on the vehicle–bridge vibrational responses under different operating conditions. First, based on the Chengdu SMT test line in China, a full-scale field measurement of the coupled vibration responses of the SMTBS is elaborately conducted under constant speed conditions. Then, the vibrational responses of the SMTBS are analyzed in the time and frequency domains to reveal its coupled vibration features and vibration transmission characteristics. Further, considering an extreme train operating condition, the vibrational responses of the SMTBS are tested and analyzed under train emergency braking; and the vibration features of the vehicle and bridge are examined for emergency braking, along with several key indexes evaluated for the train braking performance. Results show that the vibrational accelerations transmitted from the frame to the center pin and then to the carbody will be significantly decreased in turn, and the vibrational dominant frequencies of the bogie, center pin, and carbody mainly fall with 0–100[Formula: see text]Hz, 0–50[Formula: see text]Hz, and 0–20[Formula: see text]Hz, respectively. Under moving train loads, the box beam produces plentiful high-frequency vibrations and the vibrations transmitted from the driving track to the top plate are drastically reduced. The train braking significantly intensifies the car-body longitudinal vibration; however, it has small influences on the car-body vertical and lateral vibrations.


2011 ◽  
Vol 16 ◽  
pp. 825-831 ◽  
Author(s):  
Dao Gong ◽  
Wenjing Sun ◽  
Jinsong Zhou ◽  
Xiaobo Xie
Keyword(s):  

Author(s):  
Dmitriy Antipin ◽  
Nikolay Lukashov ◽  
Elena Lukashova

The quality of rail transport largely depends on the comfortable and safe movement of passengers. By the method of computer modeling, the frequencies and modes of vibration of the body, which have a negative effect on the human body, were found.


Author(s):  
Shulin Wen ◽  
Jingwei Feng ◽  
A. Krajewski ◽  
A. Ravaglioli

Hydroxyapatite bioceramics has attracted many material scientists as it is the main constituent of the bone and the teeth in human body. The synthesis of the bioceramics has been performed for years. Nowadays, the synthetic work is not only focused on the hydroapatite but also on the fluorapatite and chlorapatite bioceramics since later materials have also biological compatibility with human tissues; and they may also be very promising for clinic purpose. However, in comparison of the synthetic bioceramics with natural one on microstructure, a great differences were observed according to our previous results. We have investigated these differences further in this work since they are very important to appraise the synthetic bioceramics for their clinic application.The synthetic hydroxyapatite and chlorapatite were prepared according to A. Krajewski and A. Ravaglioli and their recent work. The briquettes from different hydroxyapatite or chlorapatite powders were fired in a laboratory furnace at the temperature of 900-1300°C. The samples of human enamel selected for the comparison with synthetic bioceramics were from Chinese adult teeth.


Author(s):  
Tong Wensheng ◽  
Lu Lianhuang ◽  
Zhang Zhijun

This is a combined study of two diffirent branches, photogrammetry and morphology of blood cells. The three dimensional quantitative analysis of erythrocytes using SEMP technique, electron computation technique and photogrammetry theory has made it possible to push the study of mophology of blood cells from LM, TEM, SEM to a higher stage, that of SEM P. A new path has been broken for deeply study of morphology of blood cells.In medical view, the abnormality of the quality and quantity of erythrocytes is one of the important changes of blood disease. It shows the abnormal blood—making function of the human body. Therefore, the study of the change of shape on erythrocytes is the indispensable and important basis of reference in the clinical diagnosis and research of blood disease.The erythrocytes of one normal person, three PNH Patients and one AA patient were used in this experiment. This research determines the following items: Height;Length of two axes (long and short), ratio; Crevice in depth and width of cell membrane; Circumference of erythrocytes; Isoline map of erythrocytes; Section map of erythrocytes.


1998 ◽  
Vol 23 (4) ◽  
pp. 382-387 ◽  
Author(s):  
James O. Ochanda ◽  
Eva A. C. Oduor ◽  
Rachel Galun ◽  
Mabel O. Imbuga ◽  
Kosta Y. Mumcuoglu

Sign in / Sign up

Export Citation Format

Share Document