Running on a Lower-Body Positive Pressure Treadmill: VO2max, Respiratory Response, and Vertical Ground Reaction Force

2013 ◽  
Vol 84 (2) ◽  
pp. 213-222 ◽  
Author(s):  
Peter C. Raffalt ◽  
Line Hovgaard-Hansen ◽  
Bente Rona Jensen
2013 ◽  
Vol 115 (2) ◽  
pp. 275-284 ◽  
Author(s):  
Thomas Schlabs ◽  
Armando Rosales-Velderrain ◽  
Heidi Ruckstuhl ◽  
Alexander C. Stahn ◽  
Alan R. Hargens

For future space exploration missions, it is important to determine the best method of simulating on Earth cardiovascular and biomechanical conditions for lunar and Martian gravities. For this purpose, we compared exercise performed within a lower body negative pressure (LBNP) and a lower body positive pressure (LBPP) chamber. Twelve subjects underwent a protocol of resting and walking (0.25 Froude) within supine LBNP and upright LBPP simulation. Each protocol was performed in simulated 1/6 G and 3/8 G. We assessed heart rate (HR), mean arterial blood pressure, oxygen consumption (V̇o2), normalized stride length, normalized vertical peak ground reaction force, duty factor, cadence, perceived exertion (Borg), and comfort of the subject. A mixed linear model was employed to determine effects of the simulation on the respective parameters. Furthermore, parameters were compared with predicted values for lunar and Martian gravities to determine the method that showed the best agreement. During walking, all cardiovascular and biomechanical parameters were unaffected by the simulation used for lunar and Martian gravities. During rest, HR and V̇o2 were lower in supine LBNP compared with upright LBPP. HR, V̇o2, and normalized vertical peak ground reaction force obtained with supine LBNP and upright LBPP showed good agreement with predicted values. Since supine LBNP and upright LBPP are lacking significant differences, we conclude that both simulations are suited to simulate the cardiovascular and biomechanical conditions during activity in lunar and Martian gravities. Operational characteristics and the intended application should be considered when choosing either supine LBNP or upright LBPP to simulate partial gravities on Earth.


2019 ◽  
Vol 126 (5) ◽  
pp. 1315-1325 ◽  
Author(s):  
Andrew B. Udofa ◽  
Kenneth P. Clark ◽  
Laurence J. Ryan ◽  
Peter G. Weyand

Although running shoes alter foot-ground reaction forces, particularly during impact, how they do so is incompletely understood. Here, we hypothesized that footwear effects on running ground reaction force-time patterns can be accurately predicted from the motion of two components of the body’s mass (mb): the contacting lower-limb (m1 = 0.08mb) and the remainder (m2 = 0.92mb). Simultaneous motion and vertical ground reaction force-time data were acquired at 1,000 Hz from eight uninstructed subjects running on a force-instrumented treadmill at 4.0 and 7.0 m/s under four footwear conditions: barefoot, minimal sole, thin sole, and thick sole. Vertical ground reaction force-time patterns were generated from the two-mass model using body mass and footfall-specific measures of contact time, aerial time, and lower-limb impact deceleration. Model force-time patterns generated using the empirical inputs acquired for each footfall matched the measured patterns closely across the four footwear conditions at both protocol speeds ( r2 = 0.96 ± 0.004; root mean squared error  = 0.17 ± 0.01 body-weight units; n = 275 total footfalls). Foot landing angles (θF) were inversely related to footwear thickness; more positive or plantar-flexed landing angles coincided with longer-impact durations and force-time patterns lacking distinct rising-edge force peaks. Our results support three conclusions: 1) running ground reaction force-time patterns across footwear conditions can be accurately predicted using our two-mass, two-impulse model, 2) impact forces, regardless of foot strike mechanics, can be accurately quantified from lower-limb motion and a fixed anatomical mass (0.08mb), and 3) runners maintain similar loading rates (ΔFvertical/Δtime) across footwear conditions by altering foot strike angle to regulate the duration of impact. NEW & NOTEWORTHY Here, we validate a two-mass, two-impulse model of running vertical ground reaction forces across four footwear thickness conditions (barefoot, minimal, thin, thick). Our model allows the impact portion of the impulse to be extracted from measured total ground reaction force-time patterns using motion data from the ankle. The gait adjustments observed across footwear conditions revealed that runners maintained similar loading rates across footwear conditions by altering foot strike angles to regulate the duration of impact.


Sports ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 51
Author(s):  
Daniel Fleckenstein ◽  
Olaf Ueberschär ◽  
Jan C. Wüstenfeld ◽  
Peter Rüdrich ◽  
Bernd Wolfarth

Lower body positive pressure treadmills (LBPPTs) as a strategy to reduce musculoskeletal load are becoming more common as part of sports conditioning, although the requisite physiological parameters are unclear. To elucidate their role, ten well-trained runners (30.2 ± 3.4 years; VO2max: 60.3 ± 4.2 mL kg−1 min−1) ran at 70% of their individual velocity at VO2max (vVO2max) on a LBPPT at 80% body weight support (80% BWSet) and 90% body weight support (90% BWSet), at 0%, 2% and 7% incline. Oxygen consumption (VO2), heart rate (HR) and blood lactate accumulation (LA) were monitored. It was found that an increase in incline led to increased VO2 values of 6.8 ± 0.8 mL kg−1 min−1 (0% vs. 7%, p < 0.001) and 5.4 ± 0.8 mL kg−1 min−1 (2% vs. 7%, p < 0.001). Between 80% BWSet and 90% BWSet, there were VO2 differences of 3.3 ± 0.2 mL kg−1 min−1 (p < 0.001). HR increased with incline by 12 ± 2 bpm (0% vs. 7%, p < 0.05) and 10 ± 2 bpm (2% vs. 7%, p < 0.05). From 80% BWSet to 90% BWSet, HR increases of 6 ± 1 bpm (p < 0.001) were observed. Additionally, LA values showed differences of 0.10 ± 0.02 mmol l−1 between 80% BWSet and 90% BWSet. Those results suggest that on a LBPPT, a 2% incline (at 70% vVO2max) is not yet sufficient to produce significant physiological changes in VO2, HR and LA—as opposed to running on conventional treadmills, where significant changes are measured. However, a 7% incline increases VO2 and HR significantly. Bringing together physiological and biomechanical factors from previous studies into this practical context, it appears that a 7% incline (at 80% BWSet) may be used to keep VO2 and HR load unchanged as compared to unsupported running, while biomechanical stress is substantially reduced.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2619
Author(s):  
Yoshiaki Kataoka ◽  
Ryo Takeda ◽  
Shigeru Tadano ◽  
Tomoya Ishida ◽  
Yuki Saito ◽  
...  

Recently, treadmills equipped with a lower-body positive-pressure (LBPP) device have been developed to provide precise body weight support (BWS) during walking. Since lower limbs are covered in a waist-high chamber of an LBPP treadmill, a conventional motion analysis using an optical method is impossible to evaluate gait kinematics on LBPP. We have developed a wearable-sensor-based three-dimensional motion analysis system, H-Gait. The purpose of the present study was to investigate the effects of BWS by a LBPP treadmill on gait kinematics using an H-Gait system. Twenty-five healthy subjects walked at 2.5 km/h on a LBPP treadmill under the following three conditions: (1) 0%BWS, (2) 25%BWS and (3) 50%BWS conditions. Acceleration and angular velocity from seven wearable sensors were used to analyze lower limb kinematics during walking. BWS significantly decreased peak angles of hip adduction, knee adduction and ankle dorsiflexion. In particular, the peak knee adduction angle at the 50%BWS significantly decreased compared to at the 25%BWS (p = 0.012) or 0%BWS (p < 0.001). The present study showed that H-Gait system can detect the changes in gait kinematics in response to BWS by a LBPP treadmill and provided a useful clinical application of the H-Gait system to walking exercises.


1992 ◽  
Vol 72 (3) ◽  
pp. 977-984 ◽  
Author(s):  
G. Geelen ◽  
P. Arbeille ◽  
J. L. Saumet ◽  
J. M. Cottet-Emard ◽  
F. Patat ◽  
...  

This study examined the hemodynamic consequences of prolonged lower body positive-pressure application and their relationship to changes in the plasma concentration of the major vasoactive hormones. Six men [36 +/- 2 (SE) yr] underwent 30 min of sitting and then 3 h of 70 degrees head-up tilt. An antigravity suit was applied (60 Torr legs, 30 Torr abdomen) during the last 2 h of tilt. In a similar noninflation experiment, the endocrine responses were measured in the suited subjects tilted for 3 h. Two-dimensional echocardiography was used to calculate ventricular volume and cardiac output. Measurements were made 30 min before and 30 and 90 min after inflation. Immediately after inflation, mean arterial pressure increased by 7 +/- 2 Torr and heart rate decreased by 16 +/- 4 beats/min. Left ventricular end-diastolic volume and systolic volume increased significantly (P less than 0.05) at 30 and 90 min of inflation. Cardiac output increased after 30 min of inflation and returned to the preinflation level at 90 min. Plasma norepinephrine and plasma renin activity were maximally suppressed after 15 and 90 min of inflation, respectively (P less than 0.05). No such hormonal changes occurred during control. Plasma sodium, potassium, and osmolality remained unchanged during both experiments. Thus, prolonged application of lower body positive pressure induces 1) a transient increase in cardiac output and 2) a marked and sustained decrease in plasma norepinephrine and plasma renin activity, which reflect an inflation-induced decrease in sympathetic activity.


1991 ◽  
Vol 71 (3) ◽  
pp. 1119-1122 ◽  
Author(s):  
R. Kram

People throughout Asia use springy bamboo poles to carry the loads of everyday life. These poles are a very compliant suspension system that allows the load to move along a nearly horizontal path while the person bounces up and down with each step. Could this be an economical way to carry loads inasmuch as no gravitational work has to be done to lift the load repeatedly? To find out, an experiment was conducted in which four male subjects ran at 3.0 m/s on a motorized treadmill with no load and while carrying a load equal to 19% body wt with compliant poles. Oxygen consumption rate, vertical ground reaction force, and the force exerted by the load on the shoulders were measured. Oxygen consumption rate increased by 22%. The same increase has previously been observed when loads are carried with a backpack. Thus compliant poles are not a particularly economical method of load carriage. However, pole suspension systems offer important advantages: they minimize peak shoulder forces and loading rates. In addition, the peak vertical ground reaction force is only slightly increased above unloaded levels when loads are carried with poles.


Sign in / Sign up

Export Citation Format

Share Document