scholarly journals Material selection process for femoral component of hip prosthesis using finite element analysis and ranking method

2017 ◽  
Vol 20 (sup1) ◽  
pp. S133-S134
Author(s):  
A. C. Messellek ◽  
M. Ould Ouali ◽  
Y. Benabid ◽  
A. Amrouche ◽  
A. Beloulla
2018 ◽  
Vol 7 (4.13) ◽  
pp. 214-220
Author(s):  
Mohd Nasri Ishak ◽  
Abd Rahim Abu Talib ◽  
Mohammad Yazdi Harmin

Current design of safety syringes requires two handed operation and additional processes which is not similar to the normal syringes. Due to this concern, a new design of safety syringe is introduced in order to produce a safety syringe which allows a single-handed operation and similar to the operation of a normal syringes. This paper presents the material selection process and design analysis of a newly devel-oped multi-purpose disposable safety syringe. Based on the design analysis, the force which needed to dismantle the nozzle is found to be 20 N and this value is practical for the end users. The finite element analysis had also shown that the design concept is safe and has safety feature for the user to use. In addition, copolymer is proven as the best material selection for safety syringe production.


2013 ◽  
Vol 577-578 ◽  
pp. 349-352 ◽  
Author(s):  
M.M. Bouziane ◽  
S. Benbarek ◽  
S.M.H. Tabeti ◽  
Bel Abbès Bachir Bouiadjra ◽  
B. Serier ◽  
...  

The designs of cemented hip femoral stems have an influence on both the quality of the metalbone cement contact and the failure rate of the cement mantle. Finite element stress technique has been used to optimize both design and material selection in load-bearing components in artificial hip joints based on the static load analysis, by selecting the peak load during the patient activity. In this study, two stem shapes (Ceraver Osteal and Charnley stems) for total hip arthoplasty (THA) were modelled. Static behaviour of these designed stem shapes were analyzed using commercial finite element analysis code ABAQUS. Linear elastic analysis is adapted; Von Mises stress and shear stress are the criterions that are of concern. Results show that, the stresses distribution in the femoral arthroplasty components depends on the material and design of the stem. In addition, the cement-bone and cement-stem interfaces seem to be crucial for the success of the hip replacement, hip prosthesis with Charnely stem induces the more stresses on the interfaces cement.


2021 ◽  
Author(s):  
R. M. Farizuan ◽  
A. R. Irfan ◽  
H. Radhwan ◽  
Shafeeq Ahmad Shamim Ahmad ◽  
Khoo Kin Fai ◽  
...  

Author(s):  
Y N Kharakh ◽  
A E Krupnin ◽  
D A Gribov ◽  
F D Sorokin ◽  
L G Kirakosyan ◽  
...  

2014 ◽  
Vol 936 ◽  
pp. 2125-2129
Author(s):  
Zhi Ying Song ◽  
Jian Yang Zhao ◽  
Rui Qing Jia

This paper focuses on materials selection and finite element analysis for flameproof enclosure of mine exploration robot. The internal environment of abandoned mine is unknown, thus the robot must be designed explosion proof. This research deals with a safe solution to environment exploration for abandoned mines by using mine exploration robot. Modeling by using 3D software and finite element analysis verifies whether enclosure strength satisfies requirements. It will provide a reference for the development of mine exploration robot.


2007 ◽  
Author(s):  
Hongqiang Guo ◽  
Dichen Li ◽  
Qin Lian ◽  
Xiang Li ◽  
Zhongmin Jin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document