Seismic Performance of Post-tensioned Precast Concrete Joints Improved with Curved Steel Braces

Author(s):  
S. C. Chen ◽  
L. Y. Zheng ◽  
W. M. Yan ◽  
Kang-Suk Kim
2018 ◽  
Vol 8 (10) ◽  
pp. 1871 ◽  
Author(s):  
Xueyuan Yan ◽  
Suguo Wang ◽  
Canling Huang ◽  
Ai Qi ◽  
Chao Hong

Precast monolithic structures are increasingly applied in construction. Such a structure has a performance somewhere between that of a pure precast structure and that of a cast-in-place structure. A precast concrete frame structure is one of the most common prefabricated structural systems. The post-pouring joint is important for controlling the seismic performance of the entire precast monolithic frame structure. This paper investigated the joints of a precast prestressed concrete frame structure. A reversed cyclic loading test was carried out on two precast prestressed concrete beam–column joints that were fabricated with two different concrete strengths in the keyway area. This testing was also performed on a cast-in-place reinforced concrete joint for comparison. The phenomena such as joint crack development, yielding, and ultimate damage were observed, and the seismic performance of the proposed precast prestressed concrete joint was determined. The results showed that the precast prestressed concrete joint and the cast-in-place joint had a similar failure mode. The stiffness, bearing capacity, ductility, and energy dissipation were comparable. The hysteresis curves were full and showed that the joints had good energy dissipation. The presence of prestressing tendons limited the development of cracks in the precast beams. The concrete strength of the keyway area had little effect on the seismic performance of the precast prestressed concrete joints. The precast prestressed concrete joints had a seismic performance that was comparable to the equivalent monolithic system.


2020 ◽  
pp. 136943322098273
Author(s):  
Baoxi Song ◽  
Weizhi Xu ◽  
Dongsheng Du ◽  
Shuguang Wang ◽  
Weiwei Li ◽  
...  

This paper provides a practical design method for hybrid unbonded post-tensioned precast concrete joints. Such joints featured with self-centering capacities have been widely favored in recent years. However, the absence of design methods hinders their further promotion. To solve the issue, two methods for calculating mechanical behavior of the joints were first studied: characteristic points method and iterative method. The effectiveness of the methods was verified by the existing test results. On this basis, a joint design method considering both yield bearing capacity and energy dissipation capacity was proposed. Moreover, to facilitate design, some factors affecting the bearing capacity were discussed. A five-story frame structure was designed by the proposed design method, and the influence of two design factors on structural response was analyzed by utilizing nonlinear time-history method. The analysis results show that: with the increase of energy dissipation factor αs, the post-earthquake residual deformation of the structure tends to increase linearly, while the accumulated damage of the structure will decrease continuously; both overdesign and underdesign of bearing capacity of the joint are unfavorable; and near-field earthquake may cause irreparable damage to structural columns, making the residual deformation of structures contrary to the self-centering capacity of joints, which shall be considered during engineering design.


2019 ◽  
Vol 22 (12) ◽  
pp. 2699-2711 ◽  
Author(s):  
Dongzhi Guan ◽  
Hui Yang ◽  
Dan Ju ◽  
Zhengxing Guo ◽  
Sen Yang

A novel precast concrete beam–column connection locally post-tensioned using arc-shaped prestressing bars was proposed for satisfactory seismic performance and rapid construction. Three full-scale cruciform specimens, including one monolithic reference specimen, were tested under reversal cyclic loadings to evaluate the seismic behaviours. Grade 630 steel rods and high-strength deformed steel rebars were used for the arc-shaped prestressing bars in the precast specimens. The results show that the proposed precast connection presents an acceptable seismic performance and that the structural details should be ameliorated to improve the energy dissipation capacity. The design philosophy of strong column-weak beam is applicable to the new precast system. Finally, a strut-and-tie model was developed to investigate the force transfer mechanism of the novel precast connection.


2012 ◽  
Vol 626 ◽  
pp. 85-89 ◽  
Author(s):  
Kay Dora Abdul Ghani ◽  
Nor Hayati Hamid

The experimental work on two full-scale precast concrete beam-column corner joints with corbels was carried out and their seismic performance was examined. The first specimen was constructed without steel fiber, while second specimen was constructed by mixed up steel fiber with concrete and placed it at the corbels area. The specimen were tested under reversible lateral cyclic loading up to ±1.5% drift. The experimental results showed that for the first specimen, the cracks start to occur at +0.5% drifts with spalling of concrete and major cracks were observed at corbel while for the second specimen, the initial cracks were observed at +0.75% with no damage at corbel. In this study, it can be concluded that precast beam-column joint without steel fiber has better ductility and stiffness than precast beam-column joint with steel fiber. However, precast beam-column joint with steel fiber has better energy dissipation and fewer cracks at corbel as compared to precast beam-column joint without steel fiber.