scholarly journals XXVI. Electromagnetic and calorimetric absolute measurements: the absolute value of Siemens's unit of resistance in electromagnetic measure; the relation between the current-work and the heat-evolution in stationary galvanic currents; and the absolute values of some constant hydroelectromotive forces in electromagnetic measure. (Condensed comparison of the results of a series of investigations.)

Author(s):  
H.F. Weber
2022 ◽  
Author(s):  
Weiler Alves Finamore ◽  
Marcelo da Silva Pinho

<div><div><div><p>A transmission medium perturbed by an additive noise from which the estimated noise power is all information known, is better modeled as a Gaussian channel. Since the Gaussian channel is, according to Information Theory, the worst channel to transmit information through, this is the most pessimistic assumption. When noise samples are available though, choosing to model the transmission medium using a more sophisticated model pays off. The Bernoulli-Gaussian channel, would be one such a choice. Finding the three parameters that characterize the Bernoulli-Gaussian stochastic process which mathematically models the noise is a task of paramount importance. Many algorithms can be used to estimate the parameters of this model based on numerical methods. In the current work a closed form expression to estimate the model parameters is presented. All that is required besides the estimation of the power of Bernoulli-Gaussian process from the available noise samples is the estimation of two additional quantities: the expected value of the absolute value of the amplitude of the process—the first absolute moment—plus the third absolute moment, viz., the expected value of the third power of the absolute value of the process. An alternative option, often used for power line communication, is to model the transmission medium as a channel in which the noise is represented by a three parameter stochastic process called Middleton Class A. Other models (like generalized-Bernoulli-Gaussian, or Bernoulli- Gaussian with memory) might render a better medium model than the Bernoulli-Gaussian channel. Estimating the parameters of these processes is however a cumbersome task and, as we show in the current work, the rate harvested by using the simple, yet more sophisticated, Bernoulli-Gaussian channel is increased as compared to the, more pessimistic, Gaussian channel, allowing one thus to more closely approach the true capacity. The communication system design can be much improved if a well fit Bernoulli-Gaussian stochastic process is selected to model the true noise. The incorporation of the Bernoulli-Gaussian channel in the communication system model leads to a better design as corroborated by the computer simulation results presented.</p></div></div></div>


2022 ◽  
Author(s):  
Weiler Alves Finamore ◽  
Marcelo da Silva Pinho

<div><div><div><p>A transmission medium perturbed by an additive noise from which the estimated noise power is all information known, is better modeled as a Gaussian channel. Since the Gaussian channel is, according to Information Theory, the worst channel to transmit information through, this is the most pessimistic assumption. When noise samples are available though, choosing to model the transmission medium using a more sophisticated model pays off. The Bernoulli-Gaussian channel, would be one such a choice. Finding the three parameters that characterize the Bernoulli-Gaussian stochastic process which mathematically models the noise is a task of paramount importance. Many algorithms can be used to estimate the parameters of this model based on numerical methods. In the current work a closed form expression to estimate the model parameters is presented. All that is required besides the estimation of the power of Bernoulli-Gaussian process from the available noise samples is the estimation of two additional quantities: the expected value of the absolute value of the amplitude of the process—the first absolute moment—plus the third absolute moment, viz., the expected value of the third power of the absolute value of the process. An alternative option, often used for power line communication, is to model the transmission medium as a channel in which the noise is represented by a three parameter stochastic process called Middleton Class A. Other models (like generalized-Bernoulli-Gaussian, or Bernoulli- Gaussian with memory) might render a better medium model than the Bernoulli-Gaussian channel. Estimating the parameters of these processes is however a cumbersome task and, as we show in the current work, the rate harvested by using the simple, yet more sophisticated, Bernoulli-Gaussian channel is increased as compared to the, more pessimistic, Gaussian channel, allowing one thus to more closely approach the true capacity. The communication system design can be much improved if a well fit Bernoulli-Gaussian stochastic process is selected to model the true noise. The incorporation of the Bernoulli-Gaussian channel in the communication system model leads to a better design as corroborated by the computer simulation results presented.</p></div></div></div>


2020 ◽  
Vol 19 (5) ◽  
pp. 369
Author(s):  
Andreia Pelegrini ◽  
André De Araújo Pinto ◽  
Hector Cris Colares De Angelo ◽  
Gaia Salvador Claumann ◽  
Diego Augusto Santos Silva ◽  
...  

Several different instruments available on the market have been used for the estimation of body fat. However, many of these instruments have not been compared with reference criteria to verify their true accuracy. This study aimed to verify the validity of a bioelectrical impedance scale (OMRON-514C) for the estimation of body fat. Forty-four overweight adolescents (25 females) participated in this study, with an average age of 12.3 ± 1.1 years. All were submitted to body fat evaluations by air displacement plethysmography and bioelectrical impedance. Higher values of relative and absolute body fat were estimated by bioelectrical impedance compared to plethysmography (p < 0.05). There was no correlation between the relative body fat measurements between the two methods (r = 0.185; p = 0.228). The absolute measurements of body fat were correlated (r = 0.497, p = 0.001). Both in the measurements of relative (p= 0.034) and absolute body fat (p = 0.021), the bioelectrical impedance overestimated the measured values. Thus, in adolescents with characteristics similar to the present study, the estimate of body fat by the bioelectrical impedance (OMRON-514C) should be used with caution.Keywords: plethysmography, bioelectrical impedance, adolescents, overweight.


2020 ◽  
Vol 11 (1) ◽  
pp. 20
Author(s):  
Muhammad Ikbal Abdullah ◽  
Andi Chairil Furqan ◽  
Nina Yusnita Yamin ◽  
Fahri Eka Oktora

This study aims to analyze the sensitivity testing using measurements of realization of regional own-source revenues and operating expenditure and to analyze the extent of the effect of sample differences between Java and non-Java provinces by using samples outside of Java. By using sensitivity analysis, the results found the influence of audit opinion on the performance of the provincial government mediated by the realization of regional operating expenditure. More specifically, when using the measurement of the absolute value of the realization of regional operating expenditure it was found that there was a direct positive and significant influence of audit opinion on the performance of the Provincial Government. However, no significant effect of audit opinion was found on the realization value of regional operating expenditure and the effect of the realization value of regional operating expenditure on the performance of the Provincial Government. This result implies that an increase in audit opinion will be more likely to be used as an incentive for the Provincial Government to increase the realization of regional operating expenditure.


1977 ◽  
Vol 32 (11-12) ◽  
pp. 908-912 ◽  
Author(s):  
H. J. Schmidt ◽  
U. Schaum ◽  
J. P. Pichotka

Abstract The influence of five different methods of homogenisation (1. The method according to Potter and Elvehjem, 2. A modification of this method called Potter S, 3. The method of Dounce, 4. Homogenisation by hypersonic waves and 5. Coarce-grained homogenisation with the “Mikro-fleischwolf”) on the absolute value and stability of oxygen uptake of guinea pig liver homogenates has been investigated in simultaneous measurements. All homogenates showed a characteristic fall of oxygen uptake during measuring time (3 hours). The modified method according to Potter and Elvehjem called Potter S showed reproducible results without any influence by homogenisation intensity.


Author(s):  
PALOMA BENGOECHEA

Abstract We refine a previous construction by Akhtari and Bhargava so that, for every positive integer m, we obtain a positive proportion of Thue equations F(x, y) = h that fail the integral Hasse principle simultaneously for every positive integer h less than m. The binary forms F have fixed degree ≥ 3 and are ordered by the absolute value of the maximum of the coefficients.


Sign in / Sign up

Export Citation Format

Share Document