A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses

2015 ◽  
Vol 60 (3) ◽  
pp. N21-N34 ◽  
Author(s):  
Mariaconcetta Longo ◽  
Luigi Rigon ◽  
Frances C M Lopez ◽  
Rongchang Chen ◽  
Diego Dreossi ◽  
...  
2002 ◽  
Author(s):  
Peter Cloetens ◽  
Wolfgang Ludwig ◽  
Elodie Boller ◽  
Lukas Helfen ◽  
Luc Salvo ◽  
...  

2010 ◽  
Vol 61 (5) ◽  
pp. 287-290 ◽  
Author(s):  
Zdenko Zápražný ◽  
Dušan Korytár ◽  
František Dubecký ◽  
Vladimír Áč ◽  
Zbigniew Stachura ◽  
...  

Experience with Imaging by Using of Microfocus X-Ray SourceIn this paper we present the current work and experience with using microfocus x-ray generator and commercial CCD camera for x-ray imaging purpose. There is a need in laboratories for the development of imaging methods approaching synchrotron radiation sources, where the brilliance of radiation is on very high-level. Generally, there is no continuous access to synchrotron facilities. Several synchrotron radiation laboratories allocate the access via a proposal system. Thus the time for synchrotron radiation experiments seldom exceeds more than 1-2 weeks per year, which restricts its application to a few selected experiments. Even in future, the routine characterization of samples will be performed mainly at the experimenters home laboratories [10]. In this contribution we show that with the present set-up it is possible to achieve the spatial resolution down to μm and with the appropriate geometry a phase contrast images are observable.


2017 ◽  
Vol 354 ◽  
pp. 1-8 ◽  
Author(s):  
Mai Elfarnawany ◽  
Seyed Alireza Rohani ◽  
Soroush Ghomashchi ◽  
Daniel G. Allen ◽  
Ning Zhu ◽  
...  

2016 ◽  
Vol 12 (4) ◽  
pp. 1623-1630 ◽  
Author(s):  
Mostafa Agour ◽  
Oltmann Riemer ◽  
Carla Flosky ◽  
Axel Meier ◽  
Ralf B. Bergmann ◽  
...  

2018 ◽  
Vol 124 (16) ◽  
pp. 164906 ◽  
Author(s):  
Cui Zhang ◽  
Xiaodong Pan ◽  
Hongjie Shang ◽  
Gongping Li

Author(s):  
Renata Longo ◽  
Maura Tonutti ◽  
Luigi Rigon ◽  
Fulvia Arfelli ◽  
Diego Dreossi ◽  
...  

The first clinical study of phase-contrast mammography (PCM) with synchrotron radiation was carried out at the Synchrotron Radiation for Medical Physics beamline of the Elettra synchrotron radiation facility in Trieste (Italy) in 2006–2009. The study involved 71 patients with unresolved breast abnormalities after conventional digital mammography and ultrasonography exams carried out at the Radiology Department of Trieste University Hospital. These cases were referred for mammography at the synchrotron radiation facility, with images acquired using a propagation-based phase-contrast imaging technique. To investigate the contribution of phase-contrast effects to the image quality, two experienced radiologists specialized in mammography assessed the visibility of breast abnormalities and of breast glandular structures. The images acquired at the hospital and at the synchrotron radiation facility were compared and graded according to a relative seven-grade visual scoring system. The statistical analysis highlighted that PCM with synchrotron radiation depicts normal structures and abnormal findings with higher image quality with respect to conventional digital mammography.