Restriction of shot noise and material noise in a multilevel photochromic memory on signal-to-noise ratio

2006 ◽  
Vol 15 (8) ◽  
pp. 1783-1787
Author(s):  
Zhang Qi-Cheng ◽  
Ni Yi ◽  
Xu Duan-Yi ◽  
Hu Heng
2018 ◽  
Vol 115 (44) ◽  
pp. 11150-11155 ◽  
Author(s):  
Miao-Hsuan Chien ◽  
Mario Brameshuber ◽  
Benedikt K. Rossboth ◽  
Gerhard J. Schütz ◽  
Silvan Schmid

Absorption microscopy is a promising alternative to fluorescence microscopy for single-molecule imaging. So far, molecular absorption has been probed optically via the attenuation of a probing laser or via photothermal effects. The sensitivity of optical probing is not only restricted by background scattering but it is fundamentally limited by laser shot noise, which minimizes the achievable single-molecule signal-to-noise ratio. Here, we present nanomechanical photothermal microscopy, which overcomes the scattering and shot-noise limit by detecting the photothermal heating of the sample directly with a temperature-sensitive substrate. We use nanomechanical silicon nitride drums, whose resonant frequency detunes with local heating. Individual Au nanoparticles with diameters from 10 to 200 nm and single molecules (Atto 633) are scanned with a heating laser with a peak irradiance of 354 ± 45 µW/µm2 using 50× long-working-distance objective. With a stress-optimized drum we reach a sensitivity of 16 fW/Hz1/2 at room temperature, resulting in a single-molecule signal-to-noise ratio of >70. The high sensitivity combined with the inherent wavelength independence of the nanomechanical sensor presents a competitive alternative to established tools for the analysis and localization of nonfluorescent single molecules and nanoparticles.


2005 ◽  
Vol 97 (8) ◽  
pp. 084701 ◽  
Author(s):  
Arjang Hassibi ◽  
Sina Zahedi ◽  
Reza Navid ◽  
Robert W. Dutton ◽  
Thomas H. Lee

2018 ◽  
Vol 17 (1) ◽  
pp. 79-86 ◽  
Author(s):  
N. A. Starasotnikau ◽  
R. V. Feodortsau

Accuracy in determination of coordinates for image having simple shapes is considered as one of important and significant parameters in metrological optoelectronic systems such as autocollimators, stellar sensors, Shack-Hartmann sensors, schemes for geometric calibration of digital cameras for aerial and space imagery, various tracking systems. The paper describes a mathematical model for a measuring stand based on a collimator which projects a test-object onto a photodetector of an optoelectronic device. The mathematical model takes into account characteristic noises for photodetectors: a shot noise of the desired signal (photon) and a shot noise of a dark signal, readout and spatial heterogeneity of CCD (charge-coupled device) matrix elements. In order to reduce noise effect it is proposed to apply the Wiener filter for smoothing an image and its unambiguous identification and also enter a threshold according to brightness level. The paper contains a comparison of two algorithms for determination of coordinates in accordance with energy gravity center and contour. Sobel, Pruitt, Roberts, Laplacian Gaussian, Canni detectors have been used for determination of the test-object contour. The essence of the algorithm for determination of coordinates lies in search for an image contour in the form of a circle with its subsequent approximation and determination of the image center. An error calculation has been made while determining coordinates of a gravity center for test-objects of various diameters: 5, 10, 20, 30, 40, 50 pixels of a photodetector and also signalto-noise ratio values: 200, 100, 70, 20, 10. Signal-to-noise ratio has been calculated as a difference between maximum image intensity of the test-object and the background which is divided by mean-square deviation of the background. The accuracy for determination of coordinates has been improved by 0.5-1 order in case when there was an increase in a signal-to-noise ratio. Accuracy improvement due to increase of a diameter in a test-object is typical for large signal-to-noise ratios: 70 or more. The conducted investigations have made it possible to establish that the algorithm for determination of coordinates of the energy gravity center is more accurate in comparison with contour methods and requires less computing power (for the MatLab software package), which is related to discreteness while determining a contour.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Dong Li ◽  
Yao Yao

AbstractThe scheme of optical imaging using scattering lens can provide a resolution beyond the classical optical diffraction limit with a coherent-state input. Nevertheless, due to the shot noise of the coherent state, the corresponding signal-to-noise ratio and resolution are both still shot-noise-limited. In order to circumvent this problem, we theoretically propose an alternative scheme where the squeezed state (with a sub-shot noise) is considered as input and the quantum noise is then suppressed below the shot-noise level. Consequently, when comparing with the previous imaging scheme (using combination of coherent state and scattering lens), our proposal is able to achieve an enhanced signal-to-noise ratio for a given scattering lens. Meanwhile, it is demonstrated that the resolution is also improved. We believe that this method may afford a new way of using squeezed states and enable a higher performance than that of using coherent state and scattering lens.


2006 ◽  
Vol 45 (29) ◽  
pp. 7667 ◽  
Author(s):  
Florian Charrière ◽  
Tristan Colomb ◽  
Frédéric Montfort ◽  
Etienne Cuche ◽  
Pierre Marquet ◽  
...  

Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Author(s):  
D. C. Joy ◽  
R. D. Bunn

The information available from an SEM image is limited both by the inherent signal to noise ratio that characterizes the image and as a result of the transformations that it may undergo as it is passed through the amplifying circuits of the instrument. In applications such as Critical Dimension Metrology it is necessary to be able to quantify these limitations in order to be able to assess the likely precision of any measurement made with the microscope.The information capacity of an SEM signal, defined as the minimum number of bits needed to encode the output signal, depends on the signal to noise ratio of the image - which in turn depends on the probe size and source brightness and acquisition time per pixel - and on the efficiency of the specimen in producing the signal that is being observed. A detailed analysis of the secondary electron case shows that the information capacity C (bits/pixel) of the SEM signal channel could be written as :


1979 ◽  
Vol 10 (4) ◽  
pp. 221-230 ◽  
Author(s):  
Veronica Smyth

Three hundred children from five to 12 years of age were required to discriminate simple, familiar, monosyllabic words under two conditions: 1) quiet, and 2) in the presence of background classroom noise. Of the sample, 45.3% made errors in speech discrimination in the presence of background classroom noise. The effect was most marked in children younger than seven years six months. The results are discussed considering the signal-to-noise ratio and the possible effects of unwanted classroom noise on learning processes.


Sign in / Sign up

Export Citation Format

Share Document