Korean-specific biokinetic model for iodine in radiological protection

Author(s):  
Tae-Eun Kwon ◽  
Yoonsun Chung ◽  
Young-Woo Jin
2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Vera Höllriegl ◽  
Nina Petoussi-Henss ◽  
Kerstin Hürkamp ◽  
Juan Camilo Ocampo Ramos ◽  
Wei Bo Li

Abstract Purpose Ra-223 dichloride (223Ra, Xofigo®) is used for treatment of patients suffering from castration-resistant metastatic prostate cancer. The objective of this work was to apply the most recent biokinetic model for radium and its progeny to show their radiopharmacokinetic behaviour. Organ absorbed doses after intravenous injection of 223Ra were estimated and compared to clinical data and data of an earlier modelling study. Methods The most recent systemic biokinetic model of 223Ra and its progeny, developed by the International Commission on Radiological Protection (ICRP), as well as the ICRP human alimentary tract model were applied for the radiopharmacokinetic modelling of Xofigo® biodistribution in patients after bolus administration. Independent kinetics were assumed for the progeny of 223Ra. The time activity curves for 223Ra were modelled and the time integrated activity coefficients, $$ \overset{\sim }{a}\left({r}_S,{T}_D\right), $$ a ~ r S T D , in the source regions for each progeny were determined. For estimating the organ absorbed doses, the Specific Absorbed Fractions (SAF) and dosimetric framework of ICRP were used together with the aforementioned $$ \overset{\sim }{a}\left({r}_S,{T}_D\right) $$ a ~ r S T D values. Results The distribution of 223Ra after injection showed a rapid plasma clearance and a low urinary excretion. Main elimination was via faeces. Bone retention was found to be about 30% at 4 h post-injection. Similar tendencies were observed in clinical trials of other authors. The highest absorbed dose coefficients were found for bone endosteum, liver and red marrow, followed by kidneys and colon. Conclusion The biokinetic modelling of 223Ra and its progeny may help to predict their distributions in patients after administration of Xofigo®. The organ dose coefficients of this work showed some variation to the values reported from clinical studies and an earlier compartmental modelling study. The dose to the bone endosteum was found to be lower by a factor of ca. 3 than previously estimated.


2020 ◽  
Vol 61 (6) ◽  
pp. 860-870
Author(s):  
Tae-Eun Kwon ◽  
Yoonsun Chung ◽  
Jaeryong Yoo ◽  
Wi-Ho Ha ◽  
Minsu Cho

Abstract Bioassay functions, which are provided by the International Commission on Radiological Protection, are used to estimate the intake activity of radionuclides; however, they include considerable uncertainties in terms of the internal dosimetry for a particular individual. During a practical internal dose assessment, the uncertainty in the bioassay function is generally not introduced because of the difficulty in quantification. Therefore, to clarify the existence of uncertainty in the bioassay function and provide dosimetrists with an insight into this uncertainty, this study attempted to quantify the uncertainty in the thyroid retention function used for radioiodine exposure. The uncertainty was quantified using a probabilistic estimation of the thyroid retention function through the propagation of the distribution of biokinetic parameters by the Monte Carlo simulation technique. The uncertainties in the thyroid retention function, expressed in terms of the scattering factor, were in the ranges of 1.55–1.60 and 1.40–1.50 for within 24 h and after 24 h, respectively. In addition, the thyroid retention function within 24 h was compared with actual measurement data to confirm the uncertainty due to the use of first-order kinetics in the biokinetic model calculation. Significantly higher thyroid uptakes (by a factor of 1.9) were observed in the actual measurements. This study indicates that consideration of the uncertainty in the thyroid retention function can avoid a significant over- and under-estimation of the internal dose, particularly when a high dose is predicted.


2020 ◽  
Author(s):  
Vera Höllriegl ◽  
Nina Petoussi-Henss ◽  
Juan Camilo Ocampo Ramos ◽  
Wei Bo Li

Abstract Purpose Ra-223-Dichloride (223Ra, Xofigo®) is used for treatment of patients suffering from castration-resistant metastatic prostate cancer. The objective of this work was to apply the most recent biokinetic model for radium and its progeny and dosimetric framework developed by the International Commission on Radiological Protection (ICRP) and to show their radiopharmacokinetic behaviour. Organ absorbed and equivalent doses after intravenous injection of 223Ra were estimated and compared to clinical data and other modelling study. Methods The most recent ICRP systemic biokinetic model of 223Ra and its progeny as well as the ICRP human alimentary tract model were applied for the radiopharmacokinetic modelling of Xofigo® biodistribution in patients after bolus administration. Independent kinetics was assumed for the progeny of 223Ra. The time activity curves for 223Ra were modelled and the time integrated activity coefficients, in the source regions for each progeny were determined. For estimating the organ absorbed doses, the Specific Absorbed Fractions (SAF) and dosimetric framework of ICRP were used together with the aforementioned values to estimate the organ absorbed and equivalent doses. Results The distribution of 223Ra after injection showed a rapid plasma clearance and a low urinary excretion. Main elimination was via faeces. Bone retention was found to be about 30% at 4 h post-injection. Similar tendencies were observed in clinic trials. The highest absorbed dose coefficients were found for bone endosteum, liver, and red marrow, followed by kidneys and colon. Conclusion The biokinetic modelling of 223Ra and its progeny may help to predict their distributions in patients after administration of Xofigo®. The organ dose coefficients of this work showed some variation to the values from clinical studies and of a previous compartmental modelling study. The dose to the bone endosteum was found to be lower by a factor of ca. 3 than previously estimated.


2019 ◽  
Vol 123 (10) ◽  
pp. 1094-1108
Author(s):  
Alexandre R. Lobo ◽  
Eduardo H. S. Gaievski ◽  
Carlos Henrique de Mesquita ◽  
Eduardo De Carli ◽  
Pryscila Dryelle S. Teixeira ◽  
...  

AbstractThe present study reports the effects of a high-fat (HF) diet of over 8 weeks on the Fe status of growing rats. Tissue Fe levels were analysed by atomic absorption spectrophotometry, and whole-body adiposity was measured by dual-energy X-ray absorptiometry. Histopathology and morphometry of adipose tissue were performed. Liver homogenates were used for measuring ferroportin-1 protein levels by immunoblotting, and transcript levels were used for Fe genes measured by real-time PCR. Tissue Fe pools were fit to a compartmental biokinetic model in which Fe was assessed using fourteen compartments and twenty-seven transfer constants (kj,i from tissue ‘i’ to tissue ‘j’) adapted from the International Commission on Radiological Protection (ICRP) 69. Ten kj,i were calculated from the experimental data using non-linear regression, and seventeen were estimated by allometry according to the formula ${k_{i,j}} = a \times {M^b}$. Validation of the model was carried out by comparing predicted and analysed Fe pool sizes in erythrocytes, the liver and the spleen. Body adiposity was negatively associated with serum Fe levels and positively associated with liver Fe stores. An inferred increase in Fe transfer from bone marrow to the liver paralleled higher hepatic Fe concentrations and ferritin heavy-chain mRNA levels in the HF diet-fed animals, suggesting that liver Fe accumulation occurred at least in part due to a favoured liver erythrocyte uptake. If this feeding condition was to be prolonged, impaired Fe decompartmentalisation may occur, ultimately resulting in dysmetabolic Fe overload.


2013 ◽  
Vol 12 (1) ◽  
pp. 57-68 ◽  
Author(s):  
Simoni Triantafyllidou ◽  
Daniel Gallagher ◽  
Marc Edwards

Previous predictions of children's blood lead levels (BLLs) through biokinetic models conclude that lead in tap water is not a primary health risk for a typical child under scenarios representative of chronic exposure, when applying a 10 μg/dL BLL of concern. Use of the US Environmental Protection Agency Integrated Exposure Uptake Biokinetic (IEUBK) model and of the International Commission on Radiological Protection (ICRP) biokinetic model to simulate children's exposure to water lead at home and at school was re-examined by expanding the scope of previous modeling efforts to consider new public health goals and improved methodology. Specifically, explicit consideration of the more sensitive population groups (e.g., young children and, particularly, formula-fed infants), the variability in BLLs amongst exposed individuals within those groups (e.g., more sensitive children at the upper tail of the BLL distribution), more conservative BLL reference values (e.g., 5 and 2 μg/dL versus 10 μg/dL) and concerns of acute exposure revealed situations where relatively low water lead levels were predicted to pose a human health concern.


2019 ◽  
Vol 7 (2A) ◽  
Author(s):  
Adriana Muniz De Almeida Albuquerque

The water purification procedure aims to obtain a product appropriate for human consumption, minimizing the presence of contaminants and toxic substances present in the water. Among these contaminants, some radionuclides of natural origin, such as uranium, thorium and their descendants, have been identified. Studies have shown that the stages of purification are quite effective in removing the radionuclides contained in water. The removal is due to co-precipitation of the radionuclides with the suspended materials and the precipitated material is accumulated and characterized as a Technologically Concentrated Natural Occurrence Radioactive Material (TENORM) by the United States Environmental Protection Agency (USEPA). This residue can present significant levels of radioactivity and, when discarded in the environment without any treatment, can generate a problem of environmental impact and a risk to the health of the population. In this way, some gamma emitters of the series of U, Th and the K-40 were determined in the residues generated at the Potable Water Treatment Plants – PWTPs in six municipalities of Pernambuco. The results obtain corroborate the classification of the residues generated in the PWTPs as concentrators of the radioactive components contained in the water supplied to the system and reinforce the need for the release to the environment, which is the usual way of disposal of this waste, to be carried out only after considering the radiological protection standards established.


2020 ◽  
Vol 3 ◽  
pp. 36-39
Author(s):  
Samson O. Paulinus ◽  
Benjamin E. Udoh ◽  
Bassey E. Archibong ◽  
Akpama E. Egong ◽  
Akwa E. Erim ◽  
...  

Objective: Physicians who often request for computed tomography (CT) scan examinations are expected to have sound knowledge of radiation exposure (risks) to patients in line with the basic radiation protection principles according to the International Commission on Radiological Protection (ICRP), the Protection of Persons Undergoing Medical Exposure or Treatment (POPUMET), and the Ionizing Radiation (Medical Exposure) Regulations (IR(ME)R). The aim is to assess the level of requesting physicians’ knowledge of ionizing radiation from CT scan examinations in two Nigerian tertiary hospitals. Materials and Methods: An 18-item-based questionnaire was distributed to 141 practicing medical doctors, excluding radiologists with work experience from 0 to >16 years in two major teaching hospitals in Nigeria with a return rate of 69%, using a voluntary sampling technique. Results: The results showed that 25% of the respondents identified CT thorax, abdomen, and pelvis examination as having the highest radiation risk, while 22% said that it was a conventional chest X-ray. Furthermore, 14% concluded that CT head had the highest risk while 9% gave their answer to be conventional abdominal X-ray. In addition, 17% inferred that magnetic resonance imaging had the highest radiation risk while 11% had no idea. Furthermore, 25.5% of the respondents have had training on ionizing radiation from CT scan examinations while 74.5% had no training. Majority (90%) of the respondents were not aware of the ICRP guidelines for requesting investigations with very little (<3%) or no knowledge (0%) on the POPUMET and the IR(ME)R respectively. Conclusion: There is low level of knowledge of ionizing radiation from CT scan examinations among requesting physicians in the study locations.


Sign in / Sign up

Export Citation Format