Highly sensitive voltammetric determination of NADH based on N-CQDs decorated SnO2/ionic liquid/carbon paste electrode

2021 ◽  
Author(s):  
Sareh Sadat Moshirian-Farahi ◽  
Hassan Ali Zamani ◽  
Mohammad Reza Abedi

Abstract A highly sensitive and selective modified electrode was successfully developed for the monitoring of nicotinamide adenine dinucleotide (NADH) in the presence of folic acid. In this regard, a carbon paste electrode (CPE) was functionalized by the nitrogen-doped carbon quantum dots/tin oxide (N-CQDs/SnO2) nanocomposite and 1-butyl-2,3-dimethyl imidazolium hexafluorophosphate ([C4DMIM][PF6]) ionic liquid (IL). The structure and surface morphology of the nanocomposite were characterized by various methods, including field emission scanning electron microscopy (FESEM), energy dispersive spectroscopy (EDS), high-resolution transmission electron microscopy (HR-TEM), and X-ray diffraction (XRD). The modified electrode displayed powerful and long-lasting electron mediating activity, with well-separated NADH and folic acid oxidation peaks. The sensing response of the developed [C4DMIM][PF6]/N-CQDs/SnO2/CPE platform was evaluated by determining NADH via the voltammetric technique under the optimized operating conditions. The current peaks of the square wave voltammograms of NADH and folic acid increased linearly with enhancing its concentrations within the ranges of 0.003 - 275 µM NADH and 0.4 - 380 µM folic acid. The detection limits for NADH and folic acid were obtained at 0.8 nM and 0.1 µM, respectively. Interference species such as glucose, urea, tryptophan, glycine, methionine, and vitamin B12 had no influence on the ability of the fabricated modified electrode to detect the target species. The low detection limit, high sensitivity, excellent selectivity, superior stability, and cost-effectiveness made it suitable for the quantification of NADH in the real biological samples with the recovery percent values in the range of 97.5 - 103%.

2018 ◽  
Vol 936 ◽  
pp. 71-76 ◽  
Author(s):  
Sri Rahmadhani ◽  
Henry Setiyanto ◽  
Muhammad Ali Zulfikar

A phenol imprinted polymer modified electrode has been prepared by electropolymerization technique in the solution containing aniline as monomer and phenol as a template onto carbon paste electrode surface. A potentiometric method was used to evaluate the performance of the electrodes. Optimization of aniline and phenol composition and a number of polymerization cycles was investigated based on the Nernstian factor. The performance of the electrode sensor is affected by the pH of the analyte solution. Based on the potential response of three different electrodes, it is known that MIP modified electrode has better sensitivity than non-imprinted electrode or bare carbon paste electrode.


2019 ◽  
Vol 84 (2) ◽  
pp. 175-185 ◽  
Author(s):  
Mohadeseh Safaei ◽  
Hadi Beitollahi ◽  
Masoud Shishehbore ◽  
Somayeh Tajik ◽  
Rahman Hosseinzadeh

A carbon paste electrode (CPE) was modified with N-(ferrocenylmethylidene) fluorene-2-amine and graphene/ZnO nanocomposite. The electrooxidation of captopril (CAP) at the surface of the modified electrode was studied using electrochemical approaches. The electrochemical study of the modified electrode, as well as its efficiency for the electrocatalytic oxidation of captopril, is described. The electrode was used to study the electrocatalytic oxidation of captopril, by cyclic voltammetry (CV), chronoamperometry (CHA) and differential pulse voltammetry (DPV) as diagnostic techniques. It has been found that the oxidation of captopril at the surface of modified electrode occurs at a potential of about 340 mV less positive than that of an unmodified CPE. DPV of captopril at the electrochemical sensor exhibited two linear dynamic ranges (0.1?100.0 and 100.0?800.0 ?M) with a detection limit (3?) of 0.05 ?M.