Positron range-free and multi-isotope tomography of positron emitters

2021 ◽  
Vol 66 (6) ◽  
pp. 065011
Author(s):  
F J Beekman ◽  
C Kamphuis ◽  
S Koustoulidou ◽  
R M Ramakers ◽  
M C Goorden
2017 ◽  
Vol 132 (11) ◽  
Author(s):  
Chong Li ◽  
Xingzhong Cao ◽  
Fuyan Liu ◽  
Haohui Tang ◽  
Zhiming Zhang ◽  
...  

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Jarmo Teuho ◽  
Leon Riehakainen ◽  
Aake Honkaniemi ◽  
Olli Moisio ◽  
Chunlei Han ◽  
...  

Abstract Background We investigated the image quality of 11C, 68Ga, 18F and 89Zr, which have different positron fractions, physical half-lifes and positron ranges. Three small animal positron emission tomography/computed tomography (PET/CT) systems were used in the evaluation, including the Siemens Inveon, RAYCAN X5 and Molecubes β-cube. The evaluation was performed on a single scanner level using the national electrical manufacturers association (NEMA) image quality phantom and analysis protocol. Acquisitions were performed with the standard NEMA protocol for 18F and using a radionuclide-specific acquisition time for 11C, 68Ga and 89Zr. Images were assessed using percent recovery coefficient (%RC), percentage standard deviation (%STD), image uniformity (%SD), spill-over ratio (SOR) and evaluation of image quantification. Results 68Ga had the lowest %RC (< 62%) across all systems. 18F had the highest maximum %RC (> 85%) and lowest %STD for the 5 mm rod across all systems. For 11C and 89Zr, the maximum %RC was close (> 76%) to the %RC with 18F. A larger SOR were measured in water with 11C and 68Ga compared to 18F on all systems. SOR in air reflected image reconstruction and data correction performance. Large variation in image quantification was observed, with maximal errors of 22.73% (89Zr, Inveon), 17.54% (89Zr, RAYCAN) and − 14.87% (68Ga, Molecubes). Conclusions The systems performed most optimal in terms of NEMA image quality parameters when using 18F, where 11C and 89Zr performed slightly worse than 18F. The performance was least optimal when using 68Ga, due to large positron range. The large quantification differences prompt optimization not only by terms of image quality but also quantification. Further investigation should be performed to find an appropriate calibration and harmonization protocol and the evaluation should be conducted on a multi-scanner and multi-center level.


Author(s):  
Rekha Goyat ◽  
Mritunjay Kumar Rai ◽  
Gulshan Kumar ◽  
Hye-Jin Kim ◽  
Se-Jung Lim

Background: Wireless Sensor Networks (WSNs) is considered one of the key research area in the recent. Various applications of WSNs need geographic location of the sensor nodes. Objective: Localization in WSNs plays an important role because without knowledge of sensor nodes location the information is useless. Finding the accurate location is very crucial in Wireless Sensor Networks. The efficiency of any localization approach is decided on the basis of accuracy and localization error. In range-free localization approaches, the location of unknown nodes are computed by collecting the information such as minimum hop count, hop size information from neighbors nodes. Methods: Although various studied have been done for computing the location of nodes but still, it is an enduring research area. To mitigate the problems of existing algorithms, a range-free Improved Weighted Novel DV-Hop localization algorithm is proposed. Main motive of the proposed study is to reduced localization error with least energy consumption. Firstly, the location information of anchor nodes is broadcasted upto M hop to decrease the energy consumption. Further, a weight factor and correction factor are introduced which refine the hop size of anchor nodes. Results: The refined hop size is further utilized for localization to reduces localization error significantly. The simulation results of the proposed algorithm are compared with other existing algorithms for evaluating the effectiveness and the performance. The simulated results are evaluated in terms localization error and computational cost by considering different parameters such as node density, percentage of anchor nodes, transmission range, effect of sensing field and effect of M on localization error. Further statistical analysis is performed on simulated results to prove the validation of proposed algorithm. A paired T-test is applied on localization error and localization time. The results of T-test depicts that the proposed algorithm significantly improves the localization accuracy with least energy consumption as compared to other existing algorithms like DV-Hop, IWCDV-Hop, and IDV-Hop. Conclusion: From the simulated results, it is concluded that the proposed algorithm offers 36% accurate localization than traditional DV-Hop and 21 % than IDV-Hop and 13% than IWCDV-Hop.


Author(s):  
Saeid Barshandeh ◽  
Mohammad Masdari ◽  
Gaurav Dhiman ◽  
Vahid Hosseini ◽  
Krishna K. Singh

2021 ◽  
Vol 6 (1) ◽  
Author(s):  
R. Mikolajczak ◽  
S. Huclier-Markai ◽  
C. Alliot ◽  
F. Haddad ◽  
D. Szikra ◽  
...  

AbstractIn the frame of “precision medicine”, the scandium radionuclides have recently received considerable interest, providing personalised adjustment of radiation characteristics to optimize the efficiency of medical care or therapeutic benefit for particular groups of patients. Radionuclides of scandium, namely scandium-43 and scandium-44 (43/44Sc) as positron emitters and scandium-47 (47Sc), beta-radiation emitter, seem to fit ideally into the concept of theranostic pair. This paper aims to review the work on scandium isotopes production, coordination chemistry, radiolabeling, preclinical studies and the very first clinical studies. Finally, standardized procedures for scandium-based radiopharmaceuticals have been proposed as a basis to pave the way for elaboration of the Ph.Eur. monographs for perspective scandium radionuclides.


2007 ◽  
Vol 54 (5) ◽  
pp. 1543-1552 ◽  
Author(s):  
Sang-June Park ◽  
W. Leslie Rogers ◽  
Neal H. Clinthorne

2011 ◽  
Vol 38 (5) ◽  
pp. 940-948 ◽  
Author(s):  
Gerrit J. Kemerink ◽  
Mariëlle G. W. Visser ◽  
Renee Franssen ◽  
Emiel Beijer ◽  
Mariangela Zamburlini ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document