Colorless movement of focal spot with arbitrary velocity based on mirrors with special shape

2021 ◽  
Author(s):  
Quanping Fan ◽  
Shenglin Wen ◽  
Shaoyi Wang ◽  
Zuhua Yang ◽  
Yong Chen ◽  
...  
Author(s):  
T. Oikawa ◽  
H. Kosugi ◽  
F. Hosokawa ◽  
D. Shindo ◽  
M. Kersker

Evaluation of the resolution of the Imaging Plate (IP) has been attempted by some methods. An evaluation method for IP resolution, which is not influenced by hard X-rays at higher accelerating voltages, was proposed previously by the present authors. This method, however, requires truoblesome experimental preperations partly because specially synthesized hematite was used as a specimen, and partly because a special shape of the specimen was used as a standard image. In this paper, a convenient evaluation method which is not infuenced by the specimen shape and image direction, is newly proposed. In this method, phase contrast images of thin amorphous film are used.Several diffraction rings are obtained by the Fourier transformation of a phase contrast image of thin amorphous film, taken at a large under focus. The rings show the spatial-frequency spectrum corresponding to the phase contrast transfer function (PCTF). The envelope function is obtained by connecting the peak intensities of the rings. The evelope function is offten used for evaluation of the instrument, because the function shows the performance of the electron microscope (EM).


Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


2020 ◽  
Vol 78 (4) ◽  
pp. 479-486
Author(s):  
Marcela Tatiana Fernandes Beserra ◽  
◽  
Ricardo Tadeu Lopes ◽  
Davi Ferreira de Oliveira ◽  
Claudio Carvalho Conti ◽  
...  

2006 ◽  
Vol 176 (9) ◽  
pp. 965
Author(s):  
B.A. Knyazev ◽  
I.A. Kotel'nikov ◽  
A.A. Tyutin ◽  
V.S. Cherkasskii

2021 ◽  
Author(s):  
Xiao Wang ◽  
Robert D. MacDougall ◽  
Peng Chen ◽  
Charles A. Bouman ◽  
Simon K. Warfield

2002 ◽  
Vol 41 (Part 1, No. 11A) ◽  
pp. 6380-6385
Author(s):  
Hyeong Ryeol Oh ◽  
Dae-Gap Gweon ◽  
Jun-Hee Lee ◽  
Sang-Cheon Kim ◽  
See-Hyung Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document