Challenges toward improvement of deuterium injection power in LHD negative-ion-based NBIs

2021 ◽  
Author(s):  
Katsuyoshi Tsumori ◽  
Katsunori Ikeda ◽  
Masashi Kisaki ◽  
Haruhisa Nakano ◽  
Kenichi Nagaoka ◽  
...  
Keyword(s):  
2018 ◽  
Author(s):  
Gilian T. Thomas ◽  
Landon MacGillivray ◽  
Natalie L. Dean ◽  
Rhonda L. Stoddard ◽  
Lars Yunker ◽  
...  

<p>Reactions carried out in the presence of rubber septa run the risk of additives being leached out by the solvent. Normally, such species are present at low enough levels that they do not interfere with the reaction significantly. However, when studying reactions using sensitive methods such as mass spectrometry, the appearance of even trace amounts of material can confuse dynamic analyses of reactions. A wide variety of additives are present in rubber along with the polymer: antioxidants, dyes, detergent, and vulcanization agents, and these are all especially problematic in negative ion mode. A redesigned Schlenk flask for pressurized sample infusion (PSI) is presented as a means of practically eliminating the presence of contaminants during reaction analyses.</p>


Author(s):  
Serkan Levent ◽  
Saniye Özcan ◽  
Aysun Geven ◽  
Nafiz Öncü Can

Introduction:: In the present study, a sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was described for the determination of ceftiofur (CEF) in cow milk and pharmaceutical preparations. CEF is an antibiotic compound, which is commonly used in the treatment of animal diseases such as respiratory system, soft tissue, and foot infections, as well as postpartum acute puerperal metritis. One of the critical features of CEF is its prescription while breastfeeding of cows; in accordance, its quantitative estimation is essential to assess its residual amounts. Methods:: In the method reported herein, after simple protein precipitation using acetonitrile, the pre-treated samples were introduced in to an LC-MS/MS instrument equipped with a Chromolith® High-Resolution RP-18 series HPLC column (100 mm × 4.6 mm from Merck KGaA, Germany). Electrospray ionization was employed as the ionization source in the triplequadrupole tandem mass spectrometer. Results:: For the calibration method using solvent-based standards; LOQ was 3.038 ng/mL, 12.15 ng/mL, and LOD was 1.215 ng/mL and 6.076 ng/mL for ESI+ and ESI- modes, respectively. On the other hand, for the method of matrix-matched standards; LOQ was 1.701 ng/mL, 10.13 ng/mL, and LOD was 0.486 ng/mL and 5.929 ng/mL for ESI+ and ESI- modes, respectively as obtained from signal to noise ratio. Conclusion:: Applicability of both positive and negative ion modes was tested, and the analyte was detected via multiple reaction monitoring. The distorting effects of the milk matrix on the MS ionization and quantitation of CEF were overcome by using matrix-matched calibration for the first time.


Sign in / Sign up

Export Citation Format

Share Document