scholarly journals A layer potential approach to functional and clinical brain imaging

2021 ◽  
Vol 2090 (1) ◽  
pp. 012146
Author(s):  
M Nemaire ◽  
P Asensio ◽  
J-M Badier ◽  
J Leblond ◽  
J-P Marmorat

Abstract In this work, we consider the inverse source recovery problem from sEEG, EEG and MEG point-wise data. We regard this as an inverse source recovery problem for L2 vector-fields normally oriented and supported on the grey/white matter interface, which together with the brain, skull and scalp form a non-homogeneous layered conductor. We assume that the quasistatic approximation of Maxwell’s equation holds for the electro-magnetic fields considered. The electric data is measured point-wise inside and outside the conductor while the magnetic data is measured only point-wise outside the conductor. These ill-posed problems are solved via Tikhonov regularization on triangulations of the interfaces and a piecewise linear model for the current on the triangles. Both in the continuous and discrete formulation the electric potential is expressed as a linear combination of double layer potentials while the magnetic flux density in the continuous case is a vector-surface integral whose discrete formulation features single layer potentials. A main feature of our approach is that these contributions can be computed exactly. Due to the consideration of the regularity conditions of the electric potential in the inverse source recovery problem, the Cauchy transmission problem for the electric potential is inadvertently solved as well. In the problem, we propagate only the electric potential while the normal derivatives at the interfaces of discontinuity of the electric conductivities are computed directly from the resulting solution. This reduces the computational complexity of the problem. There is a direct connection between the magnetic flux density and the electrical potential in conductors such as the one we explore, hence a coupling of the sEEG, EEG and MEG data for solving the respective inverse source recovery problems simultaneously is direct. We treat these problems in a unified approach that uses only single and/or double layer potentials. We provide numerical examples using realistic meshes of the head with synthetic data.

Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2522
Author(s):  
Guangdou Liu ◽  
Shiqin Hou ◽  
Xingping Xu ◽  
Wensheng Xiao

In the linear and planar motors, the 1D Halbach magnet array is extensively used. The sinusoidal property of the magnetic field deteriorates by analyzing the magnetic field at a small air gap. Therefore, a new 1D Halbach magnet array is proposed, in which the permanent magnet with a curved surface is applied. Based on the superposition of principle and Fourier series, the magnetic flux density distribution is derived. The optimized curved surface is obtained and fitted by a polynomial. The sinusoidal magnetic field is verified by comparing it with the magnetic flux density of the finite element model. Through the analysis of different dimensions of the permanent magnet array, the optimization result has good applicability. The force ripple can be significantly reduced by the new magnet array. The effect on the mass and air gap is investigated compared with a conventional magnet array with rectangular permanent magnets. In conclusion, the new magnet array design has the scalability to be extended to various sizes of motor and is especially suitable for small air gap applications.


Sensors ◽  
2020 ◽  
Vol 20 (18) ◽  
pp. 5304
Author(s):  
Ce Liang ◽  
Yanchi Zhang ◽  
Zhonggang Li ◽  
Feng Yuan ◽  
Guang Yang ◽  
...  

As an auxiliary function of the wireless power transfer (WPT) system, coil positioning can solve the power and efficiency degradation during power transmission caused by misalignment of the magnetic coupler. In this paper, a Hall sensor array is used to measure the change of magnetic flux density. By comparing the multisensor data fusion results with the preset data obtained from the coil alignment, the real-time accurate positioning of the receiving coil can be realized. Firstly, the positioning model of the receiving coil is built and the variation of magnetic flux density with the coil misalignment is analyzed. Secondly, the arrangement of the Planar 8-direction symmetric sensor array and the positioning algorithm based on data fusion of magnetic flux density variations are proposed. In order to avoid coil positioning misalignment caused by the unstable magnetic field distribution which is actually affected by the change of mutual inductance during automatic guided vehicle (AGV) alignment, the constant current strategy of primary and secondary sides is proposed. Finally, the coil positioning experimental platform is built. The experimental results show that the coil positioning method proposed in this paper has high accuracy, and the positioning error is within 4 cm.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
K. Friedrich Kuhn ◽  
Julius J. Grunow ◽  
Pascal Leimer ◽  
Marco Lorenz ◽  
David Berger ◽  
...  

AbstractDiaphragm weakness affects up to 60% of ventilated patients leading to muscle atrophy, reduction of muscle fiber force via muscle fiber injuries and prolonged weaning from mechanical ventilation. Electromagnetic stimulation of the phrenic nerve can induce contractions of the diaphragm and potentially prevent and treat loss of muscular function. Recommended safety distance of electromagnetic coils is 1 m. The aim of this study was to investigate the magnetic flux density in a typical intensive care unit (ICU) setting. Simulation of magnetic flux density generated by a butterfly coil was performed in a Berlin ICU training center with testing of potential disturbance and heating of medical equipment. Approximate safety distances to surrounding medical ICU equipment were additionally measured in an ICU training center in Bern. Magnetic flux density declined exponentially with advancing distance from the stimulation coil. Above a coil distance of 300 mm with stimulation of 100% power the signal could not be distinguished from the surrounding magnetic background noise. Electromagnetic stimulation of the phrenic nerve for diaphragm contraction in an intensive care unit setting seems to be safe and feasible from a technical point of view with a distance above 300 mm to ICU equipment from the stimulation coil.


Sign in / Sign up

Export Citation Format

Share Document