scholarly journals Design and Fabrication of Low-Cost Thermal Imaging Device Prototype to Detect Heat Energy Loss in Electrical Equipment

2021 ◽  
Vol 2107 (1) ◽  
pp. 012055
Author(s):  
A. M. Andrew ◽  
Erdy Sulino Mohd Muslim Tan ◽  
Marni Azira Markom ◽  
Mohammad Alif Hakimi Mohd Zawi

Abstract Ability to detect heat energy loss from electrical equipment can be proven crucial to avoid overheating and unexpected fire incident. The thermal remote camera was invented to prevent power outages or electrical machinery failures. Thermal imaging cameras are device which converts thermal energy (heat) into infrared spectrum to inspect a specific object or scene. Imagery that reflects the spatial variability of temperature differences in a scene observed by a thermal camera are called thermal images. Due to the complexity of the device, it can be cost and not a solution sought for. This research presents the designing and fabrication of low-cost thermal imaging cameras that plays major role in detecting heat energy losses in various applications. This prototype of thermal imaging cameras is tested to monitor and diagnose the heat health, especially in electrical installations and components in non-contact mode. Based on the test result presented, the prototype able to detect heat energy spectrum up to 80°C. The 8x8 thermal array able to calculate average temperature of the tested items.

2017 ◽  
Vol 6 (2) ◽  
Author(s):  
Andrea Ravagli ◽  
Christopher Craig ◽  
John Lincoln ◽  
Daniel W. Hewak

AbstractChalcogenide glasses are emerging as important enabling materials for low-cost infrared imaging by virtue of their transparency in the key short-wave infrared (SWIR) to long-wave infrared (LWIR) bands and the ability to be mass produced and molded into near-net shape lenses. In this paper, we introduce a new family of chalcogenide glasses, which offer visible as well as infrared transmission and improved thermal and mechanical properties. These glasses are based on Ga


2021 ◽  
Author(s):  
◽  
Matt Cryer

<p>Colloidal semiconductor nanocrystals (NCs) with bandgaps less than 1 eV allow the development of mid wave infrared (MIR) sensitive detectors that exploit the benefits of colloidal materials, primarily bandgap selection and solution deposition. Additionally, the electrical behaviour of these films can be examined for characteristics that can increase the functionality of NC based detectors.  The production of devices that are designed to be competitive as ultra-low-cost, room temperature MIR detectors, operating with photonic, rather than thermal detection is detailed. The evolution of the colloidal synthesis, spray deposition methods, substrate materials and post deposition treatments used here lead to highly robust and high performing devices. These devices demonstrate a “colour” sensitivity down to 300 nm in the MIR (≈10 % of scale), with superior responsivities for this class of device, up to 0.9 AW⁻¹, and competitive specific detectivity up to 8 × 10⁹ Jones at 200 Hz and 300 K. Furthermore, these devices utilise a cheap and robust substrate material that allows operation after deformation up to 45 ° without degradation over many cycles. These devices offer a template for ultra-low-cost MIR detectors with performance that rivals microbolometers but with better measurement speed and spectral sensitivity. As such these devices showcase the key advantages of using colloidal NCs in MIR applications.  Planar and fully air processed thin film devices that demonstrate photo-induced memristive behaviour and can be used as a transistors, photode-tectors or memory devices are investigated. Following long term (60 h) air exposure, unpackaged NC films develop reliable memristive characteristics in tandem with temperature, gate and photoresponse. On/off ratios of more than 50 are achieved and the devices show long term stability, producing repeatable metrics over days of measurement. The on/off behaviour is shown to be dependent on previous charge flow and carrier density, implying memristive rather than switching behaviour. These observations are described within a long term trap filling model. This work represents an advance in the integration of NC films into electronic devices, which may lead to the development of multi-functional electronic components.  Building on the previous work the steps taken to move from a planar device, that works well in controlled conditions, to a multi-pixel sensor that can demonstrate MIR video imaging at room temperature in a noisy environment are shown. This is achieved with a 15 pixel detector that consists only of a polymer substrate and solution patterned NC pixels. This device can detect a 373 K object with the device at 298 K in a noisy environment. This performance is enabled by photogain at 5 V bias that reaches a maximum External Quantum Efficiency (EQE) of 1940 ± 290 % for a pixel with a 3.3 µm bandgap. Through the use of four separate bandgaps it is shown that “multicolour” thermal imaging systems can deliver another layer of information, on top of intensity, to the user. The behaviour of the system is examined under use and it is shown that the photoconductive device behaves as expected with regards to bias, and that trap enabled gain is sensitive to total incident flux, more than the spectral energy distribution of the target. Finally, it is shown that solution patterned QD fabrication methods can deliver electrical reproducibility between pixels that is sufficient to allow an imaging plane of multiple pixels.  The somewhat neglected tin chalcogenide semiconductor nanocrystals are investigated and inverse MIR detection at room temperature is demonstrated with planar, solution and airprocessed PbSnTe and SnTe QD devices. The detection mechanism is shown to be mediated by an interaction between MIR radiation and the vibrational stretches of adsorbed hydroxyl species at the oxdised NC surface. Devices are shown to possess mAW⁻¹ responsivity via a reduction in film conductance due to MIR radiation and, unlike classic MIR photoconductors, are unaffected by visible wavelengths. As such these devices offer the possibility of MIR thermal imaging that has an intrinsic solution to the blinding caused by higher energy light sources.  In summary, it is shown that semiconductor NCs with an all ambient fully solution processed deposition and ligand exchange procedure can be used to create simple, robust and cheap devices that are beginning to demonstrate metrics on par with current commercial thermal detector systems. It is also shown that these devices can under certain circumstances demonstrate novel behaviours that offer the prospects of enhanced or novel functionality.</p>


2020 ◽  
Author(s):  
Rafael Y. Brzezinski ◽  
Neta Rabin ◽  
Nir Lewis ◽  
Racheli Peled ◽  
Ariel Kerpel ◽  
...  

ABSTRACTRapid and sensitive screening tools for SARS-CoV-2 infection are essential to limit the spread of COVID-19 and to properly allocate national resources. Here, we developed a new point-of-care, non-contact thermal imaging tool to detect COVID-19, based on image-processing algorithms and machine learning analysis. We captured thermal images of the back of individuals with and without COVID-19 using a portable thermal camera that connects directly to smartphones. Our novel image processing algorithms automatically extracted multiple texture and shape features of the thermal images and achieved an area under the curve (AUC) of 0.85 in detecting COVID-19 with up to 92% sensitivity. Thermal imaging scores were inversely correlated with clinical variables associated with COVID-19 disease progression. We show, for the first time, that a hand-held thermal imaging device can be used to detect COVID-19. Non-invasive thermal imaging could be used to screen for COVID-19 in out-of-hospital settings, especially in low-income regions with limited imaging resources.


2021 ◽  
Author(s):  
◽  
Matt Cryer

<p>Colloidal semiconductor nanocrystals (NCs) with bandgaps less than 1 eV allow the development of mid wave infrared (MIR) sensitive detectors that exploit the benefits of colloidal materials, primarily bandgap selection and solution deposition. Additionally, the electrical behaviour of these films can be examined for characteristics that can increase the functionality of NC based detectors.  The production of devices that are designed to be competitive as ultra-low-cost, room temperature MIR detectors, operating with photonic, rather than thermal detection is detailed. The evolution of the colloidal synthesis, spray deposition methods, substrate materials and post deposition treatments used here lead to highly robust and high performing devices. These devices demonstrate a “colour” sensitivity down to 300 nm in the MIR (≈10 % of scale), with superior responsivities for this class of device, up to 0.9 AW⁻¹, and competitive specific detectivity up to 8 × 10⁹ Jones at 200 Hz and 300 K. Furthermore, these devices utilise a cheap and robust substrate material that allows operation after deformation up to 45 ° without degradation over many cycles. These devices offer a template for ultra-low-cost MIR detectors with performance that rivals microbolometers but with better measurement speed and spectral sensitivity. As such these devices showcase the key advantages of using colloidal NCs in MIR applications.  Planar and fully air processed thin film devices that demonstrate photo-induced memristive behaviour and can be used as a transistors, photode-tectors or memory devices are investigated. Following long term (60 h) air exposure, unpackaged NC films develop reliable memristive characteristics in tandem with temperature, gate and photoresponse. On/off ratios of more than 50 are achieved and the devices show long term stability, producing repeatable metrics over days of measurement. The on/off behaviour is shown to be dependent on previous charge flow and carrier density, implying memristive rather than switching behaviour. These observations are described within a long term trap filling model. This work represents an advance in the integration of NC films into electronic devices, which may lead to the development of multi-functional electronic components.  Building on the previous work the steps taken to move from a planar device, that works well in controlled conditions, to a multi-pixel sensor that can demonstrate MIR video imaging at room temperature in a noisy environment are shown. This is achieved with a 15 pixel detector that consists only of a polymer substrate and solution patterned NC pixels. This device can detect a 373 K object with the device at 298 K in a noisy environment. This performance is enabled by photogain at 5 V bias that reaches a maximum External Quantum Efficiency (EQE) of 1940 ± 290 % for a pixel with a 3.3 µm bandgap. Through the use of four separate bandgaps it is shown that “multicolour” thermal imaging systems can deliver another layer of information, on top of intensity, to the user. The behaviour of the system is examined under use and it is shown that the photoconductive device behaves as expected with regards to bias, and that trap enabled gain is sensitive to total incident flux, more than the spectral energy distribution of the target. Finally, it is shown that solution patterned QD fabrication methods can deliver electrical reproducibility between pixels that is sufficient to allow an imaging plane of multiple pixels.  The somewhat neglected tin chalcogenide semiconductor nanocrystals are investigated and inverse MIR detection at room temperature is demonstrated with planar, solution and airprocessed PbSnTe and SnTe QD devices. The detection mechanism is shown to be mediated by an interaction between MIR radiation and the vibrational stretches of adsorbed hydroxyl species at the oxdised NC surface. Devices are shown to possess mAW⁻¹ responsivity via a reduction in film conductance due to MIR radiation and, unlike classic MIR photoconductors, are unaffected by visible wavelengths. As such these devices offer the possibility of MIR thermal imaging that has an intrinsic solution to the blinding caused by higher energy light sources.  In summary, it is shown that semiconductor NCs with an all ambient fully solution processed deposition and ligand exchange procedure can be used to create simple, robust and cheap devices that are beginning to demonstrate metrics on par with current commercial thermal detector systems. It is also shown that these devices can under certain circumstances demonstrate novel behaviours that offer the prospects of enhanced or novel functionality.</p>


2012 ◽  
Vol 2012 ◽  
pp. 1-15 ◽  
Author(s):  
Carlo Corsi

Infrared science and technology has been, since the first applications, mainly dedicated to security and surveillance especially in military field, besides specialized techniques in thermal imaging for medical diagnostic and building structures and recently in energy savings and aerospace context. Till recently the security applications were mainly based on thermal imaging as surveillance and warning military systems. In all these applications the advent of room temperature, more reliable due to the coolers avoidance, low cost, and, overall, completely integrable with Silicon technology FPAs, especially designed and tailored for specific applications, smart sensors, has really been impacted with revolutionary and new ideas and system concepts in all the infrared fields, especially for security applications. Lastly, the advent of reliable Infrared Solid State Laser Sources, operating up to the Long Infrared Wavelength Band and the new emerging techniques in Far Infrared Submillimeter Terahertz Bands, has opened wide and new areas for developing new, advanced security systems. A review of all the items with evidence of the weak and the strong points of each item, especially considering possible future developments, will be reported and discussed.


2008 ◽  
Vol 55 (2) ◽  
pp. 519-530 ◽  
Author(s):  
M.I. Fuller ◽  
K. Ranganathan ◽  
Shiwei Zhou ◽  
T.N. Blalock ◽  
J.A. Hossack ◽  
...  

2007 ◽  
Vol 10-12 ◽  
pp. 928-933
Author(s):  
Yi Wen Wang ◽  
Huan Rui Hao ◽  
Xian Li Liu ◽  
Cai Xu Yue

It is by the emissivity of the goal objects and the noise problem of the high temperature images that people are puzzled during the course of the cutting temperature tested by the application of thermal imaging device. By using thermocouples, and getting the comparison of thermocouples and the thermal imaging system temperature, we calibrate object emissivity, handle the image noise by improved median method, carry on the edge extraction of image, obtain the temperature of measured objects, and finally confirm the accuracy of the data got by the thermal imaging device with contact measurement.


Sign in / Sign up

Export Citation Format

Share Document