scholarly journals Geotechnical monitoring of a residential building being erected on strip-shell foundations in “Aquarel” housing complex in Tyumen

Author(s):  
Y A Pronozin ◽  
L R Epifantseva ◽  
M A Stepanov
2019 ◽  
Vol 265 ◽  
pp. 05032
Author(s):  
Yakov Pronozin ◽  
Tatyana Maltseva ◽  
Oleg Poroshin ◽  
Anna Medvedeva

The article presents a study of the interaction of strip foundations of multistorey apartment houses united by flat cylindrical shells with a ground base. The foundation of a 17-storey residential building has been taken as an example. The ground base consists of strong upper and highly compressible underlying layers. The use of traditional foundations under the specified conditions is hardly possible. The calculation scheme of the building and the stages of the ground foundation work are represented. Also, the researchers share the results of geotechnical monitoring in the construction process including observations of settlings at 25 points with an accuracy of 0.1 mm and measurement of layer-by-layer deformations of the ground base under the building to a depth of 10 meters from the surface. The diagrams demonstrate the actual settlement of the building with increasing load and layer-by-layer deformations of the ground base in depth are presented.


2018 ◽  
Vol 33 ◽  
pp. 02057
Author(s):  
Vyacheslav Ilyichev ◽  
Nadezhda Nikiforova ◽  
Artem Konnov

Paper presents results of scientific support to construction of unique residential building 108 m high with one storey underground part under high-rise section and 3-storey underground parking connected by underground passage. On-site soils included anthropogenic soil, clayey soils soft-stiff, saturated sands of varied grain coarseness. Design of retaining structure and support system for high-rise part excavation was developed. It suggested installation of steel pipes and struts. Construction of adjacent 3-storey underground parking by “Moscow method” is described in the paper. This method involves implementation of retaining wall consisted of prefabricated panels, truss structures (used as struts) and reinforced concrete slabs. Also design and construction technology is provided for foundations consisted of bored piles 800 MM in diameter joined by slab with base widening diameter of 1500 MM. Experiment results of static and dynamic load testing (ELDY method) are considered. Geotechnical monitoring data of adjacent building and utility systems settlement caused by construction of presented high-rise building were compared to numerical modelling results, predicted and permissible values.


2020 ◽  
Vol 17 (1) ◽  
pp. 41
Author(s):  
UMMU SHOLEHAH MOHD NOR

High residential living in Malaysia has not been widely given a significant emphasises in literature despite its increasing scale and significance in the real estate market. The significance of high rise is mainly due the increasing rate of migration from rural to urban. It is estimated a total of 77.2 percent of the Malaysian population lived in urban areas in 2020. Approximately, 30 percent of this urban population lives in strata housing. These percentages are predicted to continue to increase in the future. The emergence of high residential building has been argued as confronting various problems which has considerable impact on this life style. Satisfaction is an important outcome of living in one’s dwelling, although it is not the only consideration. High residential building in Malaysia encountered numerous problems in term of management aspects, legislation aspects, and residents’ satisfaction. The purpose of this paper is to investigate the tenants’ satisfaction living in high residential buildings in Klang Valley. The questionnaires survey is conducted amongst 276 tenants at low cost and medium cost HRB using random sampling in HRB located at areas under jurisdiction Dewan Bandaraya Kuala Lumpur (DBKL), Majlis Bandaraya Subang Jaya (MBSJ), Majlis Bandaraya Shah Alam (MBSA), Majlis Bandaraya Subang Jaya (MBSJ), Majlis Perbandaran Selayang (MPS) and Majlis Perbandaran Ampang Jaya (MPAJ). The result from this study shows that tenant in medium cost residential building are more satisfied in term of facilities and management as compared to tenants in low cost residential building. Tenants also not disclosed to the existing act and procedure related to high residential building. In conclusion, this study suggested the Local Authority to emphasise the role of tenant. These recommendation hopefully will increase the level of satisfaction amongst the residents in HRB.


2020 ◽  
Vol 7 (2) ◽  
pp. 1
Author(s):  
Khairul Azmi Mohamed ◽  
Asmat Ismail ◽  
Nur Azfahani Ahmad

The installation of an internal partition has resulted in lowering the illumination level inside a building. Therefore, this study is intended to evaluate the effects of several internal partition layout on indoor daylighting performance in student residential rooms. Several options of internal partition were simulated using Climate Based Daylight Modelling (CBDM) to suggest the effective partition layout to overcome low daylighting level inside the room at the annual level. The findings indicate that the internal partition perpendicular to the window layout has been proven to have the highest annual daylight sufficiency in a student residential room in the tropics.


Sign in / Sign up

Export Citation Format

Share Document